AXMK/PE LC Low Carbon
Download product group datasheet
Aluminium power cable for fixed installations outdoors. May be buried directly in soil, also by ploughing. UV-protected oversheath and core insulation. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free, but without fire protection. The cable is not CPR-classified. Made of low-carbon aluminum and up to 45% of the sheath material is recycled plastic.
| Standards | SFS 5800, HD 603 5 E |
|---|---|
| Product Environmental Profile (PEP) | PEP NXNS-00650-V0101-EN.pdf |
| Conductor | 25 mm² circular stranded aluminium, EN/IEC 60228 class 2 35-300 mm² sector shaped, stranded aluminium, EN/IEC 60228 class 2 |
| Insulation | UV-protected cross-linked polyethylene XLPE |
| Core Identification (all color combinations in the cable family) | Yellow-green, brown, black, grey |
| Inner covering | Plastic tape |
| Oversheath | UV-protected polyethylene compound PELLD |
| Colour of the oversheath | Black |
4x25 S Low Carbon
Electric number
Size
Packaging
Voltage
4x25 S Low Carbon
Conductor material
Aluminium
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
0.9
Number of wires
4
Min. bending radius
During handling and installation, cable mm
267
In final installation, cable mm
187
During handling and installation, phase conductor cm
13
During handling and installation, cable cm
27
In final installation, phase conductor cm
8
In final installation, cable cm
19
During handling and installation, cable m
0.27
In final installation, cable m
0.19
Max. pulling force
Pulling-eye kN
1.5
Pulling-stocking kN
1.5
Resistance 20 °C Ω/km
1,20
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176310052
Reka code
1116150
4x35 S Low Carbon
Electric number
Size
Packaging
Voltage
4x35 S Low Carbon
Conductor material
Aluminium
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
0.9
Number of wires
4
Min. bending radius
During handling and installation, cable mm
266
In final installation, cable mm
186
During handling and installation, phase conductor cm
16
During handling and installation, cable cm
27
In final installation, phase conductor cm
11
In final installation, cable cm
19
During handling and installation, cable m
0.27
In final installation, cable m
0.19
Max. pulling force
Pulling-eye kN
2.1
Pulling-stocking kN
2.1
Resistance 20 °C Ω/km
0,868
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176310069
Reka code
1116151
4x50 S Low Carbon
Electric number
Size
Packaging
Voltage
4x50 S Low Carbon
Conductor material
Aluminium
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1
Number of wires
4
Min. bending radius
During handling and installation, cable mm
312
In final installation, cable mm
218
During handling and installation, phase conductor cm
19
During handling and installation, cable cm
31
In final installation, phase conductor cm
13
In final installation, cable cm
22
During handling and installation, cable m
0.31
In final installation, cable m
0.22
Max. pulling force
Pulling-eye kN
3
Pulling-stocking kN
3
Resistance 20 °C Ω/km
0,641
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176310076
Reka code
1116152
4x70 S Low Carbon
Electric number
Size
Packaging
Voltage
4x70 S Low Carbon
Conductor material
Aluminium
Nominal cross-sectional area of conductor mm2
70
Nominal thickness of insulation mm
1.1
Number of wires
4
Min. bending radius
During handling and installation, cable mm
350
In final installation, cable mm
245
During handling and installation, phase conductor cm
23
During handling and installation, cable cm
35
In final installation, phase conductor cm
16
In final installation, cable cm
25
During handling and installation, cable m
0.35
In final installation, cable m
0.24
Max. pulling force
Pulling-eye kN
4.2
Pulling-stocking kN
4.2
Resistance 20 °C Ω/km
0,443
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176310083
Reka code
1116153
4x95 S Low Carbon
Electric number
Size
Packaging
Voltage
4x95 S Low Carbon
Conductor material
Aluminium
Nominal cross-sectional area of conductor mm2
95
Nominal thickness of insulation mm
1.1
Number of wires
4
Min. bending radius
During handling and installation, cable mm
400
In final installation, cable mm
280
During handling and installation, phase conductor cm
26
During handling and installation, cable cm
40
In final installation, phase conductor cm
18
In final installation, cable cm
28
During handling and installation, cable m
0.4
In final installation, cable m
0.28
Max. pulling force
Pulling-eye kN
5.7
Pulling-stocking kN
5.7
Resistance 20 °C Ω/km
0,320
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176310090
Reka code
1116154
4x120 S Low Carbon
Electric number
Size
Packaging
Voltage
4x120 S Low Carbon
Conductor material
Aluminium
Nominal cross-sectional area of conductor mm2
120
Nominal thickness of insulation mm
1.2
Number of wires
4
Min. bending radius
During handling and installation, cable mm
450
In final installation, cable mm
315
During handling and installation, phase conductor cm
29
During handling and installation, cable cm
45
In final installation, phase conductor cm
20
In final installation, cable cm
32
During handling and installation, cable m
0.45
In final installation, cable m
0.32
Max. pulling force
Pulling-eye kN
7.2
Pulling-stocking kN
7.2
Resistance 20 °C Ω/km
0,253
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176310106
Reka code
1116155
4x150 S Low Carbon
Electric number
Size
Packaging
Voltage
4x150 S Low Carbon
Conductor material
Aluminium
Nominal cross-sectional area of conductor mm2
150
Nominal thickness of insulation mm
1.4
Number of wires
4
Min. bending radius
During handling and installation, cable mm
499
In final installation, cable mm
349
During handling and installation, phase conductor cm
32
During handling and installation, cable cm
50
In final installation, phase conductor cm
23
In final installation, cable cm
35
During handling and installation, cable m
0.5
In final installation, cable m
0.35
Max. pulling force
Pulling-eye kN
9
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,206
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176310113
Reka code
1116156
4x185 S Low Carbon
Electric number
Size
Packaging
Voltage
4x185 S Low Carbon
Conductor material
Aluminium
Nominal cross-sectional area of conductor mm2
185
Nominal thickness of insulation mm
1.6
Number of wires
4
Min. bending radius
During handling and installation, cable mm
547
In final installation, cable mm
383
During handling and installation, phase conductor cm
37
During handling and installation, cable cm
55
In final installation, phase conductor cm
26
In final installation, cable cm
38
During handling and installation, cable m
0.55
In final installation, cable m
0.38
Max. pulling force
Pulling-eye kN
11.1
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,164
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176310120
Reka code
1116157
4x240 S Low Carbon
Electric number
Size
Packaging
Voltage
4x240 S Low Carbon
Conductor material
Aluminium
Nominal cross-sectional area of conductor mm2
240
Nominal thickness of insulation mm
1.7
Number of wires
4
Min. bending radius
During handling and installation, cable mm
633
In final installation, cable mm
443
During handling and installation, phase conductor cm
43
During handling and installation, cable cm
63
In final installation, phase conductor cm
30
In final installation, cable cm
44
During handling and installation, cable m
0.63
In final installation, cable m
0.44
Max. pulling force
Pulling-eye kN
14.4
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,125
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176310137
Reka code
1116158
4x300 S Low Carbon
Electric number
Size
Packaging
Voltage
4x300 S Low Carbon
Conductor material
Aluminium
Nominal cross-sectional area of conductor mm2
300
Nominal thickness of insulation mm
1.8
Number of wires
4
Min. bending radius
During handling and installation, cable mm
678
In final installation, cable mm
474
During handling and installation, phase conductor cm
46
During handling and installation, cable cm
68
In final installation, phase conductor cm
32
In final installation, cable cm
47
During handling and installation, cable m
0.68
In final installation, cable m
0.47
Max. pulling force
Pulling-eye kN
18
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,100
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176310144
Reka code
1116159