AXMK GY


Aluminium power cable for fixed installations indoors and outdoors. May be buried directly in soil. Installations must be in accordance with national regulations and rules of installations. The cable is flame-retardant according to CPR-class Eca.
Standards | SFS 4879, SS 424 14 18, HD 603 5 D & O |
---|---|
Reaction to fire | Eca |
CPR - DoP | 2017030_DOP.pdf |
Conductor | 16...25 mm² circular stranded aluminium, EN/IEC 60228 class 2 |
Insulation | UV-protected XLPE |
Core Identification (all color combinations in the cable family) | Green/Yellow, brown, black, grey Green/Yellow, blue, brown, black, grey |
Inner covering | Plastic tape |
Oversheath | UV-protected PVC compound |
Colour of the oversheath | Grey |
4x16 S GY
Electric number
Size
Packaging
Voltage
4x16 S GY
Nominal diameter of complete cable mm
19
Nominal weight of cable kg/km
369
Conductor material
Aluminum
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
0.7
Number of wires
4
Min. bending radius
During handling and installation, cable mm
226
In final installation, cable mm
158
During handling and installation, phase conductor cm
10
During handling and installation, cable cm
23
In final installation, phase conductor cm
7
In final installation, cable cm
16
During handling and installation, cable m
0.23
In final installation, cable m
0.16
Max. pulling force
Pulling-eye kN
1
Pulling-stocking kN
1
Resistance 20 °C Ω/km
1.91
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006262069
Reka code
1116347
4x25 S GY
Electric number
Size
Packaging
Voltage
4x25 S GY
Nominal diameter of complete cable mm
22
Nominal weight of cable kg/km
518
Conductor material
Aluminum
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
0.9
Number of wires
4
Min. bending radius
During handling and installation, cable mm
267
In final installation, cable mm
187
During handling and installation, phase conductor cm
9
During handling and installation, cable cm
27
In final installation, phase conductor cm
6
In final installation, cable cm
19
During handling and installation, cable m
0.27
In final installation, cable m
0.19
Max. pulling force
Pulling-eye kN
1.5
Pulling-stocking kN
1.5
Resistance 20 °C Ω/km
1.20
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006262526
Reka code
1703480