FRHF control
Download product group datasheet
Fire-resistant control cable for fixed installations indoors and outdoors. Not to be laid in soil nor directly in cast concrete. For locations where safety requires the operation of alarm, control, signalling and energy circuits also during a fire. The conductor insulation must be protected against UV-radiation. Installations must be in accordance with national regulations and rules of installations. No requirement for CPR-classification.
Standards | HD 627 7 D-1 |
---|---|
Conductor | Circular solid copper, EN/IEC 60228 class 1 |
Insulation | Halogen-free XLPE, mica tape |
Core Identification (all color combinations in the cable family) | Black, with white numbers |
Separation sheath | Halogen-free filling compound |
Oversheath | UV-protected halogen-free polyolefin compound |
Colour of the oversheath | Orange |
7x1,5
Electric number
Size
Packaging
Voltage
7x1,5
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
280
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
7
Min. bending radius
During handling and installation, cable mm
164
In final installation, cable mm
115
During handling and installation, cable cm
16
In final installation, cable cm
11
Max. pulling force
Pulling-eye kN
0.53
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410004128824
Reka code
1145581
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
280
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
7
Min. bending radius
During handling and installation, cable mm
164
In final installation, cable mm
115
During handling and installation, cable cm
16
In final installation, cable cm
11
Max. pulling force
Pulling-eye kN
0.53
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410004128800
Reka code
1145581
12x1,5
Electric number
Size
Packaging
Voltage
12x1,5
Nominal diameter of complete cable mm
18
Nominal weight of cable kg/km
459
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
12
Min. bending radius
During handling and installation, cable mm
216
In final installation, cable mm
151
During handling and installation, cable cm
22
In final installation, cable cm
15
Max. pulling force
Pulling-eye kN
0.9
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410004128862
Reka code
1145585
Nominal diameter of complete cable mm
18
Nominal weight of cable kg/km
459
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
12
Min. bending radius
During handling and installation, cable mm
216
In final installation, cable mm
151
During handling and installation, cable cm
22
In final installation, cable cm
15
Max. pulling force
Pulling-eye kN
0.9
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410004128831
Reka code
1145585
19x1,5
Electric number
Size
Packaging
Voltage
19x1,5
Nominal diameter of complete cable mm
22
Nominal weight of cable kg/km
670
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
19
Min. bending radius
During handling and installation, cable mm
262
In final installation, cable mm
183
During handling and installation, cable cm
26
In final installation, cable cm
18
Max. pulling force
Pulling-eye kN
1.43
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410004128879
Reka code
1145587
Nominal diameter of complete cable mm
22
Nominal weight of cable kg/km
670
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
19
Min. bending radius
During handling and installation, cable mm
262
In final installation, cable mm
183
During handling and installation, cable cm
26
In final installation, cable cm
18
Max. pulling force
Pulling-eye kN
1.43
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410004128848
Reka code
1145587
27x1,5
Electric number
Size
Packaging
Voltage
27x1,5
Nominal diameter of complete cable mm
26
Nominal weight of cable kg/km
924
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
27
Min. bending radius
During handling and installation, cable mm
308
In final installation, cable mm
216
During handling and installation, cable cm
31
In final installation, cable cm
22
Max. pulling force
Pulling-eye kN
2.03
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410004128855
Reka code
1145591
7x2,5
Electric number
Size
Packaging
Voltage
7x2,5
Nominal diameter of complete cable mm
16
Nominal weight of cable kg/km
405
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
7
Min. bending radius
During handling and installation, cable mm
192
In final installation, cable mm
134
During handling and installation, cable cm
19
In final installation, cable cm
13
Max. pulling force
Pulling-eye kN
0.88
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410004128923
Reka code
1145596
12x2,5
Electric number
Size
Packaging
Voltage
12x2,5
Nominal diameter of complete cable mm
20
Nominal weight of cable kg/km
624
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
12
Min. bending radius
During handling and installation, cable mm
244
In final installation, cable mm
171
During handling and installation, cable cm
24
In final installation, cable cm
17
Max. pulling force
Pulling-eye kN
1.5
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410004128930
Reka code
1145598
19x2,5
Electric number
Size
Packaging
Voltage
19x2,5
Nominal diameter of complete cable mm
25
Nominal weight of cable kg/km
932
Conductor material
Copper
Nominal diameter of conductor mm
1.75
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
19
Min. bending radius
During handling and installation, cable mm
300
In final installation, cable mm
210
During handling and installation, cable cm
30
In final installation, cable cm
21
Max. pulling force
Pulling-eye kN
2.38
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410004128947
Reka code
1145599
27x2,5
Electric number
Size
Packaging
Voltage
27x2,5
Nominal diameter of complete cable mm
29
Nominal weight of cable kg/km
1288
Conductor material
Copper
Nominal diameter of conductor mm
1.75
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
27
Min. bending radius
During handling and installation, cable mm
353
In final installation, cable mm
247
During handling and installation, cable cm
35
In final installation, cable cm
25
Max. pulling force
Pulling-eye kN
3.38
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410004128954
Reka code
1145607