AXLJ-F TT 12/20 (24) kV 3x1-core CAS
Download product group datasheet
Medium-voltage cable for fixed installations outdoors. May be buried directly in soil, also by ploughing. Cable is longitudinally and radially watertight and therefore it is suitable where wet soil and / or fresh water permanently occurs. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free, but without fire protection. The cable is not CPR-classified.
| Standards | HD 620 10 M, SS 424 14 16 |
|---|---|
| Conductor | Watertight, circular, stranded aluminium, EN/IEC 60228 class 2 |
| Conductor screen | Semiconducting cross-linked polyethylene XLPE |
| Insulation | Cross-linked polyethylene XLPE |
| Insulation screen | Semiconducting cross-linked polyethylene XLPE |
| Core Identification (all color combinations in the cable family) | White phase numbering: L1, L2, L3 |
| Inner covering | Water swellable tape under and over screen |
| Metal screen | Copper wires and aluminium foil (CAS). Polyethylene laminated aluminium foil acts as a part of the metallic screen and needs to be connected in cable joints and terminations |
| Radial watertightness | Polyethylene laminated aluminium foil bonded to the sheath |
| Oversheath | UV-protected PE-plastic PELLD |
| Colour of the oversheath | Black |
3x1x50/16 CAS
Electric number
Size
Packaging
Voltage
3x1x50/16 CAS
Nominal diameter of complete cable mm
58
Nominal weight of cable kg/km
1913
Conductor material
Aluminium
Nominal diameter of conductor mm
8
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
5.5
Nominal diameter over the insulation without insulation screen mm
19.2
Number of wires
3
Nominal size of metal screen mm2
16
Min. bending radius
During handling and installation, cable mm
705
In final installation, cable mm
494
During handling and installation, phase conductor cm
41
During handling and installation, cable cm
71
In final installation, phase conductor cm
28
In final installation, cable cm
49
During handling and installation, phase conductor m
0.41
During handling and installation, cable m
0.7
In final installation, phase conductor m
0.28
In final installation, cable m
0.49
Max. pulling force
Pulling-eye kN
4.5
Pulling-stocking kN
2.3
Resistance 20 °C Ω/km
0,641
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,2
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006275052
Reka code
1181302
3x1x95/16 CAS
Electric number
Size
Packaging
Voltage
3x1x95/16 CAS
Nominal diameter of complete cable mm
65
Nominal weight of cable kg/km
2553
Conductor material
Aluminium
Nominal diameter of conductor mm
11.1
Nominal cross-sectional area of conductor mm2
95
Nominal thickness of insulation mm
5.5
Nominal diameter over the insulation without insulation screen mm
22.3
Number of wires
3
Nominal size of metal screen mm2
16
Min. bending radius
During handling and installation, cable mm
789
In final installation, cable mm
552
During handling and installation, phase conductor cm
45
During handling and installation, cable cm
79
In final installation, phase conductor cm
32
In final installation, cable cm
55
During handling and installation, phase conductor m
0.45
During handling and installation, cable m
0.79
In final installation, phase conductor m
0.32
In final installation, cable m
0.55
Max. pulling force
Pulling-eye kN
8.6
Pulling-stocking kN
4.3
Resistance 20 °C Ω/km
0,320
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,2
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006275069
Reka code
1181304
3x1x150/25 CAS
Electric number
Size
Packaging
Voltage
3x1x150/25 CAS
Nominal diameter of complete cable mm
72
Nominal weight of cable kg/km
3345
Conductor material
Aluminium
Nominal diameter of conductor mm
13.9
Nominal cross-sectional area of conductor mm2
150
Nominal thickness of insulation mm
5.5
Nominal diameter over the insulation without insulation screen mm
25.1
Number of wires
3
Nominal size of metal screen mm2
25
Min. bending radius
During handling and installation, cable mm
867
In final installation, cable mm
607
During handling and installation, phase conductor cm
50
During handling and installation, cable cm
87
In final installation, phase conductor cm
35
In final installation, cable cm
61
During handling and installation, phase conductor m
0.5
During handling and installation, cable m
0.87
In final installation, phase conductor m
0.35
In final installation, cable m
0.61
Max. pulling force
Pulling-eye kN
13.5
Pulling-stocking kN
6.8
Resistance 20 °C Ω/km
0,206
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,8
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006275076
Reka code
1181306
3x1x240/25 CAS
Electric number
Size
Packaging
Voltage
3x1x240/25 CAS
Nominal diameter of complete cable mm
82
Nominal weight of cable kg/km
4519
Conductor material
Aluminium
Nominal diameter of conductor mm
17.8
Nominal cross-sectional area of conductor mm2
240
Nominal thickness of insulation mm
5.5
Nominal diameter over the insulation without insulation screen mm
29
Number of wires
3
Nominal size of metal screen mm2
25
Min. bending radius
During handling and installation, cable mm
979
In final installation, cable mm
685
During handling and installation, phase conductor cm
57
During handling and installation, cable cm
98
In final installation, phase conductor cm
40
In final installation, cable cm
69
During handling and installation, phase conductor m
0.57
During handling and installation, cable m
0.98
In final installation, phase conductor m
0.4
In final installation, cable m
0.69
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,125
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,8
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006275083
Reka code
1181308