MMO

Standards HD 627 S1:1996/A2:2005 Part 4 Section D-1
Reaction to fire Eca
CPR - DoP 2017047_DOP.pdf
Conductor Circular solid copper, EN/IEC 60228 class 1

7x1,5

Electric number Size Packaging Voltage

7x1,5

Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 203
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 88
During handling and installation, cable cm 11
In final installation, cable cm 9
Max. pulling force
Pulling-eye kN 0.53
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128220
Reka code 1103207
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 203
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 88
During handling and installation, cable cm 11
In final installation, cable cm 9
Max. pulling force
Pulling-eye kN 0.53
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128138
Reka code 1103207
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 203
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 88
During handling and installation, cable cm 11
In final installation, cable cm 9
Max. pulling force
Pulling-eye kN 0.53
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128091
Reka code 1103207
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 203
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 88
During handling and installation, cable cm 11
In final installation, cable cm 9
Max. pulling force
Pulling-eye kN 0.53
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128121
Reka code 1103207
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 203
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 88
During handling and installation, cable cm 11
In final installation, cable cm 9
Max. pulling force
Pulling-eye kN 0.53
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304105
Reka code 1103207
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 203
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 88
During handling and installation, cable cm 11
In final installation, cable cm 9
Max. pulling force
Pulling-eye kN 0.53
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128107
Reka code 1103207

12x1,5

Electric number Size Packaging Voltage

12x1,5

Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 325
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 150
In final installation, cable mm 120
During handling and installation, cable cm 15
In final installation, cable cm 12
Max. pulling force
Pulling-eye kN 0.9
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128237
Reka code 1103212
Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 325
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 150
In final installation, cable mm 120
During handling and installation, cable cm 15
In final installation, cable cm 12
Max. pulling force
Pulling-eye kN 0.9
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128275
Reka code 1103212
Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 325
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 150
In final installation, cable mm 120
During handling and installation, cable cm 15
In final installation, cable cm 12
Max. pulling force
Pulling-eye kN 0.9
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128114
Reka code 1103212

19x1,5

Electric number Size Packaging Voltage

19x1,5

Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 476
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 170
In final installation, cable mm 136
During handling and installation, cable cm 17
In final installation, cable cm 14
Max. pulling force
Pulling-eye kN 1.43
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128244
Reka code 1103219
Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 476
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 170
In final installation, cable mm 136
During handling and installation, cable cm 17
In final installation, cable cm 14
Max. pulling force
Pulling-eye kN 1.43
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128145
Reka code 1103219

27x1,5

Electric number Size Packaging Voltage

27x1,5

Nominal diameter of complete cable mm 20
Nominal weight of cable kg/km 663
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 200
In final installation, cable mm 160
During handling and installation, cable cm 20
In final installation, cable cm 16
Max. pulling force
Pulling-eye kN 2.03
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128251
Reka code 1103227
Nominal diameter of complete cable mm 20
Nominal weight of cable kg/km 663
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 200
In final installation, cable mm 160
During handling and installation, cable cm 20
In final installation, cable cm 16
Max. pulling force
Pulling-eye kN 2.03
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128152
Reka code 1103227

7x2,5

Electric number Size Packaging Voltage

7x2,5

Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 292
Conductor material Copper
Nominal diameter of conductor mm 1.74
Min. bending radius
During handling and installation, cable mm 130
In final installation, cable mm 104
During handling and installation, cable cm 13
In final installation, cable cm 10
Max. pulling force
Pulling-eye kN 0.88
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128329
Reka code 1103057
Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 292
Conductor material Copper
Nominal diameter of conductor mm 1.74
Min. bending radius
During handling and installation, cable mm 130
In final installation, cable mm 104
During handling and installation, cable cm 13
In final installation, cable cm 10
Max. pulling force
Pulling-eye kN 0.88
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128169
Reka code 1103057

19x2,5

Electric number Size Packaging Voltage

19x2,5

Nominal diameter of complete cable mm 20
Nominal weight of cable kg/km 719
Conductor material Copper
Nominal diameter of conductor mm 1.75
Min. bending radius
During handling and installation, cable mm 200
In final installation, cable mm 160
During handling and installation, cable cm 20
In final installation, cable cm 16
Max. pulling force
Pulling-eye kN 2.38
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128176
Reka code 1103269
Nominal diameter of complete cable mm 20
Nominal weight of cable kg/km 719
Conductor material Copper
Nominal diameter of conductor mm 1.75
Min. bending radius
During handling and installation, cable mm 200
In final installation, cable mm 160
During handling and installation, cable cm 20
In final installation, cable cm 16
Max. pulling force
Pulling-eye kN 2.38
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128343
Reka code 1103269

37x1,5

Electric number Size Packaging Voltage

37x1,5

Nominal diameter of complete cable mm 24
Nominal weight of cable kg/km 914
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 240
In final installation, cable mm 192
During handling and installation, cable cm 24
In final installation, cable cm 19
Max. pulling force
Pulling-eye kN 2.78
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128268
Reka code 1103237
Nominal diameter of complete cable mm 24
Nominal weight of cable kg/km 914
Conductor material Copper
Nominal diameter of conductor mm 1.36
Min. bending radius
During handling and installation, cable mm 240
In final installation, cable mm 192
During handling and installation, cable cm 24
In final installation, cable cm 19
Max. pulling force
Pulling-eye kN 2.78
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128282
Reka code 1103237

12x2,5

Electric number Size Packaging Voltage

12x2,5

Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 473
Conductor material Copper
Nominal diameter of conductor mm 1.74
Min. bending radius
During handling and installation, cable mm 170
In final installation, cable mm 136
During handling and installation, cable cm 17
In final installation, cable cm 14
Max. pulling force
Pulling-eye kN 1.5
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128336
Reka code 1103262

27x2,5

Electric number Size Packaging Voltage

27x2,5

Nominal diameter of complete cable mm 24
Nominal weight of cable kg/km 1006
Conductor material Copper
Nominal diameter of conductor mm 1.75
Min. bending radius
During handling and installation, cable mm 240
In final installation, cable mm 192
During handling and installation, cable cm 24
In final installation, cable cm 19
Max. pulling force
Pulling-eye kN 3.38
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128374
Reka code 1103277
Nominal diameter of complete cable mm 24
Nominal weight of cable kg/km 1006
Conductor material Copper
Nominal diameter of conductor mm 1.75
Min. bending radius
During handling and installation, cable mm 240
In final installation, cable mm 192
During handling and installation, cable cm 24
In final installation, cable cm 19
Max. pulling force
Pulling-eye kN 3.38
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128350
Reka code 1103277

37x2,5

Electric number Size Packaging Voltage

37x2,5

Nominal diameter of complete cable mm 27
Nominal weight of cable kg/km 1360
Conductor material Copper
Nominal diameter of conductor mm 1.75
Min. bending radius
During handling and installation, cable mm 270
In final installation, cable mm 216
During handling and installation, cable cm 27
In final installation, cable cm 22
Max. pulling force
Pulling-eye kN 4.63
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128381
Reka code 1103287
Nominal diameter of complete cable mm 27
Nominal weight of cable kg/km 1360
Conductor material Copper
Nominal diameter of conductor mm 1.75
Min. bending radius
During handling and installation, cable mm 270
In final installation, cable mm 216
During handling and installation, cable cm 27
In final installation, cable cm 22
Max. pulling force
Pulling-eye kN 4.63
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004128367
Reka code 1103287