EQQ-HF D BK - IFXI-LX D BK - MMJ-D BK Helppo

Download product group datasheet

Installation cable for fixed installations indoors and outdoors. Not to be laid in soil nor directly in cast concrete. Can be embedded to the groove filled with plaster. UV-protected oversheath and core insulation. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free and flame-retardant according to CPR-class Dca-s2,d2,a2.

Standards SS 424 02 19-5
Reaction to fire Dca-s2,d2,a2
CPR - DoP 2025005_DOP.pdf
Conductor Circular solid copper, EN/IEC 60228 class 1
Insulation UV-protected polyethylene compound
Core Identification (all color combinations in the cable family) 3G: Yellow-green, blue, brown
5G: Yellow-green, blue, brown, black, grey
Oversheath UV-protected polyolefin compound
Colour of the oversheath Black

3G1,5

Electric number Size Packaging Voltage

3G1,5

Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 3
Min. bending radius
During handling and installation, cable mm 75
In final installation, cable mm 22
During handling and installation, cable cm 7
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176309834
Reka code 1254796
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 3
Min. bending radius
During handling and installation, cable mm 75
In final installation, cable mm 22
During handling and installation, cable cm 7
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176309841
Reka code 1254796

5G1,5

Electric number Size Packaging Voltage

5G1,5

Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 5
Min. bending radius
During handling and installation, cable mm 88
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176309872
Reka code 1254798
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 5
Min. bending radius
During handling and installation, cable mm 88
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176309889
Reka code 1254798

3G2,5

Electric number Size Packaging Voltage

3G2,5

Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 3
Min. bending radius
During handling and installation, cable mm 87
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176309858
Reka code 1254799
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 3
Min. bending radius
During handling and installation, cable mm 87
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176309865
Reka code 1254799

5G2,5

Electric number Size Packaging Voltage

5G2,5

Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 5
Min. bending radius
During handling and installation, cable mm 103
In final installation, cable mm 31
During handling and installation, cable cm 10
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176309896
Reka code 1254801
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 5
Min. bending radius
During handling and installation, cable mm 103
In final installation, cable mm 31
During handling and installation, cable cm 10
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176309902
Reka code 1254801