HHJ LiteRex C

Installation cable for fixed installations in dry indoors, on surface or inlaid in conduit canals. Can also be used in medical facilities where higher fire class is required. Not to be laid in soil nor directly in cast concrete. Insulation and sheath materials are UV-resistant.

Standards SS 424 02 19-5:2014
Reaction to fire Cca-s1,d1,a1
CPR - DoP 2021009_DOP.pdf
2018008_DOP.pdf
Conductor Circular solid copper, EN/IEC 60228 class 1
Insulation Halogen free UV-resistant polyethylene
Core Identification (all color combinations in the cable family) Blue, brown
Brown, black, grey
Blue, brown, black, grey
Blue, brown, black, grey, black
Yellow-green, blue, brown
Yellow-green, blue, brown, black
Yellow-green, blue, brown, black, grey
Oversheath Halogen free UV-resistant polyolefin compound
Colour of the oversheath White

3x1,5 S

Electric number Size Packaging Voltage

3x1,5 S

Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 103
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 3
Bending radius
During handling and installation, cable mm 80
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Pulling force
Pulling-eye kN 0.23
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300558
Reka code 1150139
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 103
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 3
Bending radius
During handling and installation, cable mm 80
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Pulling force
Pulling-eye kN 0.23
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304372
Reka code 1150139
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 103
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 3
Bending radius
During handling and installation, cable mm 80
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Pulling force
Pulling-eye kN 0.23
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300534
Reka code 1150139
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 103
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 3
Bending radius
During handling and installation, cable mm 80
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Pulling force
Pulling-eye kN 0.23
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304020
Reka code 1150139
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 103
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 3
Bending radius
During handling and installation, cable mm 80
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Pulling force
Pulling-eye kN 0.23
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300541
Reka code 1150139

4x1,5 S

Electric number Size Packaging Voltage

4x1,5 S

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 125
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 4
Bending radius
During handling and installation, cable mm 90
In final installation, cable mm 27
During handling and installation, cable cm 9
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304037
Reka code 1150140
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 125
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 4
Bending radius
During handling and installation, cable mm 90
In final installation, cable mm 27
During handling and installation, cable cm 9
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300572
Reka code 1150140
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 125
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 4
Bending radius
During handling and installation, cable mm 90
In final installation, cable mm 27
During handling and installation, cable cm 9
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300589
Reka code 1150140
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 125
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 4
Bending radius
During handling and installation, cable mm 90
In final installation, cable mm 27
During handling and installation, cable cm 9
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300565
Reka code 1150140

5x1,5 S

Electric number Size Packaging Voltage

5x1,5 S

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 148
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 5
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.38
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300619
Reka code 1150141
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 148
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 5
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.38
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304396
Reka code 1150141
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 148
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 5
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.38
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300596
Reka code 1150141
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 148
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 5
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.38
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304044
Reka code 1150141
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 148
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 5
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.38
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300602
Reka code 1150141

3x2,5 S

Electric number Size Packaging Voltage

3x2,5 S

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 144
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 3
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.38
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300671
Reka code 1150143
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 144
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 3
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.38
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300657
Reka code 1150143
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 144
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 3
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.38
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304419
Reka code 1150143
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 144
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 3
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.38
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304068
Reka code 1150143
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 144
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 3
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.38
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300664
Reka code 1150143

4x2,5 S

Electric number Size Packaging Voltage

4x2,5 S

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 178
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 4
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300701
Reka code 1150144
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 178
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 4
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300688
Reka code 1150144
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 178
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 4
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300695
Reka code 1150144

5x2,5 S

Electric number Size Packaging Voltage

5x2,5 S

Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 212
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 5
Bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.63
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300718
Reka code 1150145
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 212
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 5
Bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.63
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304433
Reka code 1150145
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 212
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 5
Bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.63
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300732
Reka code 1150145
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 212
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 5
Bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.63
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304075
Reka code 1150145
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 212
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 5
Bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.63
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300725
Reka code 1150145

2x1,5 N

Electric number Size Packaging Voltage

2x1,5 N

Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 83
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 2
Bending radius
During handling and installation, cable mm 80
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Pulling force
Pulling-eye kN 0.15
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300503
Reka code 1150138
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 83
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 2
Bending radius
During handling and installation, cable mm 80
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Pulling force
Pulling-eye kN 0.15
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300510
Reka code 1150138
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 83
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 2
Bending radius
During handling and installation, cable mm 80
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Pulling force
Pulling-eye kN 0.15
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300527
Reka code 1150138

3x1,5 N

Electric number Size Packaging Voltage

3x1,5 N

Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 103
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 3
Bending radius
During handling and installation, cable mm 80
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Pulling force
Pulling-eye kN 0.23
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176305089
Reka code 1150150

4x1,5 N

Electric number Size Packaging Voltage

4x1,5 N

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 125
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 4
Bending radius
During handling and installation, cable mm 90
In final installation, cable mm 27
During handling and installation, cable cm 9
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176305096
Reka code 1150151

5x1,5 N

Electric number Size Packaging Voltage

5x1,5 N

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 148
Conductor material Copper
Nominal diameter of conductor mm 1.36
Number of wires 5
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.38
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12.1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176305102
Reka code 1150152

2x2,5 N

Electric number Size Packaging Voltage

2x2,5 N

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 113
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 2
Bending radius
During handling and installation, cable mm 90
In final installation, cable mm 27
During handling and installation, cable cm 9
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300626
Reka code 1150142
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 113
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 2
Bending radius
During handling and installation, cable mm 90
In final installation, cable mm 27
During handling and installation, cable cm 9
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304051
Reka code 1150142
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 113
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 2
Bending radius
During handling and installation, cable mm 90
In final installation, cable mm 27
During handling and installation, cable cm 9
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300640
Reka code 1150142
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 113
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 2
Bending radius
During handling and installation, cable mm 90
In final installation, cable mm 27
During handling and installation, cable cm 9
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176300633
Reka code 1150142

3x2,5 N

Electric number Size Packaging Voltage

3x2,5 N

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 144
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 3
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.38
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176305119
Reka code 1150153

4x2,5 N

Electric number Size Packaging Voltage

4x2,5 N

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 178
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 4
Bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176305126
Reka code 1150154

5x2,5 N

Electric number Size Packaging Voltage

5x2,5 N

Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 212
Conductor material Copper
Nominal diameter of conductor mm 1.74
Number of wires 5
Bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Pulling force
Pulling-eye kN 0.63
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176305133
Reka code 1150155