EQLQ WF LiteRex
Download product group datasheet
Installation cable for fixed installations indoors and outdoors. Not to be laid in soil nor directly in cast concrete. Can be embedded to the groove filled with plaster. UV-protected oversheath and core insulation. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free and flame-retardant according to CPR-class Dca-s2,d2,a2.
Standards | SS 424 02 19-6 |
---|---|
Reaction to fire | Dca-s2,d2,a2 |
CPR - DoP | 2022001_DOP.pdf |
Conductor | Circular solid copper, EN/IEC 60228 class 1 |
Insulation | Halogen free UV-resistant polyethylene |
Core Identification (all color combinations in the cable family) | Yellowgreen, blue, brown Yellowgreen, blue, brown, black Yellowgreen, blue, brown, black, grey |
Separation sheath | Halogen free filling compound |
Oversheath | Halogen free UV-resistant polyolefin compound |
Colour of the oversheath | White |
3G1,5
Electric number
Size
Packaging
Voltage
3G1,5
Nominal diameter of complete cable mm
10
Nominal weight of cable kg/km
137
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
3
Min. bending radius
During handling and installation, cable mm
93
In final installation, cable mm
28
During handling and installation, cable cm
9
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.23
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228548
Reka code
1254737
Nominal diameter of complete cable mm
10
Nominal weight of cable kg/km
137
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
3
Min. bending radius
During handling and installation, cable mm
93
In final installation, cable mm
28
During handling and installation, cable cm
9
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.23
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228562
Reka code
1254737
Nominal diameter of complete cable mm
10
Nominal weight of cable kg/km
137
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
3
Min. bending radius
During handling and installation, cable mm
93
In final installation, cable mm
28
During handling and installation, cable cm
9
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.23
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228555
Reka code
1254737
4G1,5
Electric number
Size
Packaging
Voltage
4G1,5
Nominal diameter of complete cable mm
11
Nominal weight of cable kg/km
160
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
4
Min. bending radius
During handling and installation, cable mm
100
In final installation, cable mm
30
During handling and installation, cable cm
10
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.3
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228609
Reka code
1254738
Nominal diameter of complete cable mm
11
Nominal weight of cable kg/km
160
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
4
Min. bending radius
During handling and installation, cable mm
100
In final installation, cable mm
30
During handling and installation, cable cm
10
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.3
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228616
Reka code
1254738
Nominal diameter of complete cable mm
11
Nominal weight of cable kg/km
160
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
4
Min. bending radius
During handling and installation, cable mm
100
In final installation, cable mm
30
During handling and installation, cable cm
10
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.3
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228623
Reka code
1254738
5G1,5
Electric number
Size
Packaging
Voltage
5G1,5
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
180
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
5
Min. bending radius
During handling and installation, cable mm
106
In final installation, cable mm
32
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228685
Reka code
1254739
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
180
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
5
Min. bending radius
During handling and installation, cable mm
106
In final installation, cable mm
32
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228678
Reka code
1254739
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
180
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
5
Min. bending radius
During handling and installation, cable mm
106
In final installation, cable mm
32
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228661
Reka code
1254739
3G2,5
Electric number
Size
Packaging
Voltage
3G2,5
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
184
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
3
Min. bending radius
During handling and installation, cable mm
105
In final installation, cable mm
32
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228579
Reka code
1254741
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
184
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
3
Min. bending radius
During handling and installation, cable mm
105
In final installation, cable mm
32
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228593
Reka code
1254741
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
184
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
3
Min. bending radius
During handling and installation, cable mm
105
In final installation, cable mm
32
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228586
Reka code
1254741
4G2,5
Electric number
Size
Packaging
Voltage
4G2,5
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
215
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
4
Min. bending radius
During handling and installation, cable mm
113
In final installation, cable mm
34
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.5
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228647
Reka code
1254742
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
215
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
4
Min. bending radius
During handling and installation, cable mm
113
In final installation, cable mm
34
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.5
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228654
Reka code
1254742
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
215
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
4
Min. bending radius
During handling and installation, cable mm
113
In final installation, cable mm
34
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.5
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228630
Reka code
1254742
5G2,5
Electric number
Size
Packaging
Voltage
5G2,5
Nominal diameter of complete cable mm
13
Nominal weight of cable kg/km
248
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
5
Min. bending radius
During handling and installation, cable mm
123
In final installation, cable mm
37
During handling and installation, cable cm
12
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.63
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228715
Reka code
1254743
Nominal diameter of complete cable mm
13
Nominal weight of cable kg/km
248
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
5
Min. bending radius
During handling and installation, cable mm
123
In final installation, cable mm
37
During handling and installation, cable cm
12
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.63
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228708
Reka code
1254743
Nominal diameter of complete cable mm
13
Nominal weight of cable kg/km
248
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
5
Min. bending radius
During handling and installation, cable mm
123
In final installation, cable mm
37
During handling and installation, cable cm
12
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.63
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228692
Reka code