EQLQ WF LiteRex

Download product group datasheet

Installation cable for fixed installations indoors and outdoors. Not to be laid in soil nor directly in cast concrete. Can be embedded to the groove filled with plaster. UV-protected oversheath and core insulation. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free and flame-retardant according to CPR-class Dca-s2,d2,a2.

Standards SS 424 02 19-6
Reaction to fire Dca-s2,d2,a2
CPR - DoP 2022001_DOP.pdf
Conductor Circular solid copper, EN/IEC 60228 class 1
Insulation Halogen free UV-resistant polyethylene
Core Identification (all color combinations in the cable family) Yellowgreen, blue, brown
Yellowgreen, blue, brown, black
Yellowgreen, blue, brown, black, grey
Separation sheath Halogen free filling compound
Oversheath Halogen free UV-resistant polyolefin compound
Colour of the oversheath White

3G1,5

Electric number Size Packaging Voltage

3G1,5

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 137
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 3
Min. bending radius
During handling and installation, cable mm 93
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228548
Reka code 1254737
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 137
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 3
Min. bending radius
During handling and installation, cable mm 93
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228562
Reka code 1254737
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 137
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 3
Min. bending radius
During handling and installation, cable mm 93
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228555
Reka code 1254737

4G1,5

Electric number Size Packaging Voltage

4G1,5

Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 160
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 4
Min. bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.3
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228609
Reka code 1254738
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 160
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 4
Min. bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.3
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228616
Reka code 1254738
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 160
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 4
Min. bending radius
During handling and installation, cable mm 100
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.3
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228623
Reka code 1254738

5G1,5

Electric number Size Packaging Voltage

5G1,5

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 180
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 5
Min. bending radius
During handling and installation, cable mm 106
In final installation, cable mm 32
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228685
Reka code 1254739
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 180
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 5
Min. bending radius
During handling and installation, cable mm 106
In final installation, cable mm 32
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228678
Reka code 1254739
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 180
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 5
Min. bending radius
During handling and installation, cable mm 106
In final installation, cable mm 32
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228661
Reka code 1254739

3G2,5

Electric number Size Packaging Voltage

3G2,5

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 184
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 3
Min. bending radius
During handling and installation, cable mm 105
In final installation, cable mm 32
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228579
Reka code 1254741
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 184
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 3
Min. bending radius
During handling and installation, cable mm 105
In final installation, cable mm 32
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228593
Reka code 1254741
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 184
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 3
Min. bending radius
During handling and installation, cable mm 105
In final installation, cable mm 32
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228586
Reka code 1254741

4G2,5

Electric number Size Packaging Voltage

4G2,5

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 215
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 4
Min. bending radius
During handling and installation, cable mm 113
In final installation, cable mm 34
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.5
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228647
Reka code 1254742
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 215
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 4
Min. bending radius
During handling and installation, cable mm 113
In final installation, cable mm 34
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.5
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228654
Reka code 1254742
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 215
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 4
Min. bending radius
During handling and installation, cable mm 113
In final installation, cable mm 34
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.5
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228630
Reka code 1254742

5G2,5

Electric number Size Packaging Voltage

5G2,5

Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 248
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 5
Min. bending radius
During handling and installation, cable mm 123
In final installation, cable mm 37
During handling and installation, cable cm 12
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 0.63
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228715
Reka code 1254743
Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 248
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 5
Min. bending radius
During handling and installation, cable mm 123
In final installation, cable mm 37
During handling and installation, cable cm 12
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 0.63
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228708
Reka code 1254743
Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 248
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 5
Min. bending radius
During handling and installation, cable mm 123
In final installation, cable mm 37
During handling and installation, cable cm 12
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 0.63
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176228692
Reka code 1254743