XCMK-HF / EXQJ / IFSI-Cu

Download product group datasheet

Copper power cable for fixed installations indoors and outdoors. May be buried directly in soil. The conductor insulation must be protected against UV-radiation. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free and flame-retardant according to CPR-class Dca-s2,d2,a2.

Standards SFS 5546, SS 424 14 18, HD 604 5 I & D, IEC 60502-1
Reaction to fire Dca-s2,d2,a2
CPR - DoP 2021012_DOP.pdf
Conductor Circular solid copper, EN/IEC 60228 class 1
Insulation Cross-linked polyethylene XLPE
Core Identification (all color combinations in the cable family) Blue, brown
Brown, black, grey
Blue, brown, black, grey
Inner covering Halogen free filling compound
Metal screen Copper wires and copper tape
Oversheath UV-protected polyolefin compound
Colour of the oversheath Black

2x1,5/1,5

Electric number Size Packaging Voltage

2x1,5/1,5

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 187
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 14
In final installation, cable cm 10
During handling and installation, cable m 0.14
In final installation, cable m 0.1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176011607
Reka code 1146105

2x2,5/2,5

Electric number Size Packaging Voltage

2x2,5/2,5

Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 235
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 15
In final installation, cable cm 11
During handling and installation, cable m 0.15
In final installation, cable m 0.1
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176011614
Reka code 1146106
Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 235
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 15
In final installation, cable cm 11
During handling and installation, cable m 0.15
In final installation, cable m 0.1
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176219393
Reka code 1146106

2x4/4

Electric number Size Packaging Voltage

2x4/4

Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 302
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 17
In final installation, cable cm 12
During handling and installation, cable m 0.17
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.4
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 4,61
Maximum d.c. resistance at 20 °C, metal screen Ω/km 4,61
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176011621
Reka code 1146107

2x6/6

Electric number Size Packaging Voltage

2x6/6

Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 383
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 18
In final installation, cable cm 12
During handling and installation, cable m 0.18
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.6
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176011638
Reka code 1146108
Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 383
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 18
In final installation, cable cm 12
During handling and installation, cable m 0.18
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.6
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006029907
Reka code 1146108

3x1,5/1,5

Electric number Size Packaging Voltage

3x1,5/1,5

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 205
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 15
In final installation, cable cm 10
During handling and installation, cable m 0.15
In final installation, cable m 0.1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006023172
Reka code 1146225
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 205
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 15
In final installation, cable cm 10
During handling and installation, cable m 0.15
In final installation, cable m 0.1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006023189
Reka code 1146225

3x2,5/2,5

Electric number Size Packaging Voltage

3x2,5/2,5

Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 254
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 16
In final installation, cable cm 11
During handling and installation, cable m 0.16
In final installation, cable m 0.11
Max. pulling force
Pulling-eye kN 0.4
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006023202
Reka code 1146226
Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 254
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 16
In final installation, cable cm 11
During handling and installation, cable m 0.16
In final installation, cable m 0.11
Max. pulling force
Pulling-eye kN 0.4
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006023196
Reka code 1146226

3x4/4

Electric number Size Packaging Voltage

3x4/4

Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 338
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 17
In final installation, cable cm 12
During handling and installation, cable m 0.17
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.6
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 4,61
Maximum d.c. resistance at 20 °C, metal screen Ω/km 4,61
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176011706
Reka code 1146227

3x6/6

Electric number Size Packaging Voltage

3x6/6

Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 437
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 19
In final installation, cable cm 13
During handling and installation, cable m 0.18
In final installation, cable m 0.13
Max. pulling force
Pulling-eye kN 0.9
Pulling-stocking kN 0.3
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006023257
Reka code 1146228
Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 437
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 19
In final installation, cable cm 13
During handling and installation, cable m 0.18
In final installation, cable m 0.13
Max. pulling force
Pulling-eye kN 0.9
Pulling-stocking kN 0.3
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006023301
Reka code 1146228

4x1,5/1,5

Electric number Size Packaging Voltage

4x1,5/1,5

Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 230
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 16
In final installation, cable cm 11
During handling and installation, cable m 0.15
In final installation, cable m 0.11
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006023615
Reka code 1146305
Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 230
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 16
In final installation, cable cm 11
During handling and installation, cable m 0.15
In final installation, cable m 0.11
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006023622
Reka code 1146305

4x2,5/2,5

Electric number Size Packaging Voltage

4x2,5/2,5

Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 292
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 17
In final installation, cable cm 12
During handling and installation, cable m 0.17
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006023639
Reka code 1146306
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 292
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 17
In final installation, cable cm 12
During handling and installation, cable m 0.17
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006023646
Reka code 1146306

4x4/4

Electric number Size Packaging Voltage

4x4/4

Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 393
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 18
In final installation, cable cm 13
During handling and installation, cable m 0.18
In final installation, cable m 0.13
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 4,61
Maximum d.c. resistance at 20 °C, metal screen Ω/km 4,61
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176011850
Reka code 1146307

4x6/6

Electric number Size Packaging Voltage

4x6/6

Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 521
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 20
In final installation, cable cm 14
During handling and installation, cable m 0.2
In final installation, cable m 0.14
Max. pulling force
Pulling-eye kN 1.2
Pulling-stocking kN 0.4
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006023004
Reka code 1146308
Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 521
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 20
In final installation, cable cm 14
During handling and installation, cable m 0.2
In final installation, cable m 0.14
Max. pulling force
Pulling-eye kN 1.2
Pulling-stocking kN 0.4
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006023219
Reka code 1146308