JOMPPI


JOMPPI for fixed installations outdoors. Covered conductor for tranformer connections. Installations must be in accordance with national regulations and rules of installations. The cable is not CPR-classified.
Standards | EN 50397-1, SFS 5790 |
---|---|
Conductor | Circular stranded aluminium, SFS 5791 |
Insulation | UV-protected XLPE |
50
Electric number
Size
Packaging
Voltage
50
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
208
Conductor material
Aluminum
Nominal diameter of conductor mm
9
Nominal thickness of insulation mm
2.3
Min. bending radius
During handling and installation, cable mm
140
In final installation, cable mm
140
During handling and installation, cable cm
14
In final installation, cable cm
14
Max. pulling force
Resistance 20 °C Ω/km
0.72
EAN code
6410001240505
Reka code
1117098
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
208
Conductor material
Aluminum
Nominal diameter of conductor mm
9
Nominal thickness of insulation mm
2.3
Min. bending radius
During handling and installation, cable mm
140
In final installation, cable mm
140
During handling and installation, cable cm
14
In final installation, cable cm
14
Max. pulling force
Resistance 20 °C Ω/km
0.72
EAN code
6410001240499
Reka code
1117098
95
Electric number
Size
Packaging
Voltage
95
Nominal diameter of complete cable mm
17
Nominal weight of cable kg/km
380
Conductor material
Aluminum
Nominal diameter of conductor mm
13
Nominal thickness of insulation mm
2.3
Min. bending radius
During handling and installation, cable mm
170
In final installation, cable mm
170
During handling and installation, cable cm
17
In final installation, cable cm
17
Max. pulling force
Resistance 20 °C Ω/km
0.363
EAN code
6410001240956
Reka code
1117100
Nominal diameter of complete cable mm
17
Nominal weight of cable kg/km
380
Conductor material
Aluminum
Nominal diameter of conductor mm
13
Nominal thickness of insulation mm
2.3
Min. bending radius
During handling and installation, cable mm
170
In final installation, cable mm
170
During handling and installation, cable cm
17
In final installation, cable cm
17
Max. pulling force
Resistance 20 °C Ω/km
0.363
EAN code
6410001240932
Reka code
1117100
Nominal diameter of complete cable mm
17
Nominal weight of cable kg/km
380
Conductor material
Aluminum
Nominal diameter of conductor mm
13
Nominal thickness of insulation mm
2.3
Min. bending radius
During handling and installation, cable mm
170
In final installation, cable mm
170
During handling and installation, cable cm
17
In final installation, cable cm
17
Max. pulling force
Resistance 20 °C Ω/km
0.363
EAN code
6410001240949
Reka code
1117100
120
Electric number
Size
Packaging
Voltage
120
Nominal diameter of complete cable mm
20
Nominal weight of cable kg/km
485
Conductor material
Aluminum
Nominal diameter of conductor mm
15
Nominal thickness of insulation mm
2.3
Min. bending radius
During handling and installation, cable mm
200
In final installation, cable mm
200
During handling and installation, cable cm
20
In final installation, cable cm
20
Max. pulling force
Resistance 20 °C Ω/km
0.288
EAN code
6410001241205
Reka code
1117101
Nominal diameter of complete cable mm
20
Nominal weight of cable kg/km
485
Conductor material
Aluminum
Nominal diameter of conductor mm
15
Nominal thickness of insulation mm
2.3
Min. bending radius
During handling and installation, cable mm
200
In final installation, cable mm
200
During handling and installation, cable cm
20
In final installation, cable cm
20
Max. pulling force
Resistance 20 °C Ω/km
0.288
EAN code
6410001240987
Reka code
1117101