EMCMK-HF C / FXQJ-EMC C / IFSI-EMC-Cu C
Download product group datasheet
Copper power cable for fixed installations indoors and outdoors. May be buried directly in soil. Can also be used in medical facilities where higher fire class is required. EMC shielded cable gives an excellent protection against electromagnetic disturbancies. The conductor insulation must be protected against UV-radiation. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free and flame-retardant according to CPR-class Cca-s1,d1,a1.
Standards | SFS 5546, SS 424 14 18, HD 604 5 I & D, IEC 60502-1 |
---|---|
Reaction to fire | Cca-s1,d1,a1 |
CPR - DoP | 2019003_DOP.pdf |
Conductor | Sector shaped, stranded aluminium, EN/IEC 60228 class 2 |
Insulation | Cross-linked polyethylene XLPE |
Core Identification (all color combinations in the cable family) | Brown, black, grey Blue, brown, black, grey |
Inner covering | Plastic tape |
Metal screen | EMC-copper foil and copper wires |
Oversheath | UV-protected polyolefin compound |
Colour of the oversheath | Black |
3x35/16
Electric number
Size
Packaging
Voltage
3x35/16
Nominal diameter of complete cable mm
23
Nominal weight of cable kg/km
1378
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
0.9
Number of wires
3
Min. bending radius
During handling and installation, cable cm
28
In final installation, cable cm
19
During handling and installation, cable m
0.28
In final installation, cable m
0.19
Max. pulling force
Pulling-eye kN
5.3
Pulling-stocking kN
1.6
Resistance 20 °C Ω/km
0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303221
Reka code
1146777
Nominal diameter of complete cable mm
23
Nominal weight of cable kg/km
1378
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
0.9
Number of wires
3
Min. bending radius
During handling and installation, cable cm
28
In final installation, cable cm
19
During handling and installation, cable m
0.28
In final installation, cable m
0.19
Max. pulling force
Pulling-eye kN
5.3
Pulling-stocking kN
1.6
Resistance 20 °C Ω/km
0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303214
Reka code
1146777
3x50/25
Electric number
Size
Packaging
Voltage
3x50/25
Nominal diameter of complete cable mm
26
Nominal weight of cable kg/km
1877
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1
Number of wires
3
Min. bending radius
During handling and installation, cable cm
32
In final installation, cable cm
22
During handling and installation, cable m
0.32
In final installation, cable m
0.22
Max. pulling force
Pulling-eye kN
7.5
Pulling-stocking kN
2.3
Resistance 20 °C Ω/km
0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,727
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303252
Reka code
1146778
Nominal diameter of complete cable mm
26
Nominal weight of cable kg/km
1877
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1
Number of wires
3
Min. bending radius
During handling and installation, cable cm
32
In final installation, cable cm
22
During handling and installation, cable m
0.32
In final installation, cable m
0.22
Max. pulling force
Pulling-eye kN
7.5
Pulling-stocking kN
2.3
Resistance 20 °C Ω/km
0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,727
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303245
Reka code
1146778
3x70/35
Electric number
Size
Packaging
Voltage
3x70/35
Nominal diameter of complete cable mm
30
Nominal weight of cable kg/km
2584
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
70
Nominal thickness of insulation mm
1.1
Number of wires
3
Min. bending radius
During handling and installation, cable cm
36
In final installation, cable cm
26
During handling and installation, cable m
0.36
In final installation, cable m
0.26
Max. pulling force
Pulling-eye kN
10.5
Pulling-stocking kN
3.2
Resistance 20 °C Ω/km
0,268
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,524
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303276
Reka code
1146779
Nominal diameter of complete cable mm
30
Nominal weight of cable kg/km
2584
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
70
Nominal thickness of insulation mm
1.1
Number of wires
3
Min. bending radius
During handling and installation, cable cm
36
In final installation, cable cm
26
During handling and installation, cable m
0.36
In final installation, cable m
0.26
Max. pulling force
Pulling-eye kN
10.5
Pulling-stocking kN
3.2
Resistance 20 °C Ω/km
0,268
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,524
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303283
Reka code
1146779
3x95/50
Electric number
Size
Packaging
Voltage
3x95/50
Nominal diameter of complete cable mm
34
Nominal weight of cable kg/km
3473
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
95
Nominal thickness of insulation mm
1.1
Number of wires
3
Min. bending radius
During handling and installation, cable cm
40
In final installation, cable cm
28
During handling and installation, cable m
0.4
In final installation, cable m
0.28
Max. pulling force
Pulling-eye kN
14.3
Pulling-stocking kN
4.3
Resistance 20 °C Ω/km
0,193
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,387
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303313
Reka code
1146780
Nominal diameter of complete cable mm
34
Nominal weight of cable kg/km
3473
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
95
Nominal thickness of insulation mm
1.1
Number of wires
3
Min. bending radius
During handling and installation, cable cm
40
In final installation, cable cm
28
During handling and installation, cable m
0.4
In final installation, cable m
0.28
Max. pulling force
Pulling-eye kN
14.3
Pulling-stocking kN
4.3
Resistance 20 °C Ω/km
0,193
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,387
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303306
Reka code
1146780
3x120/70
Electric number
Size
Packaging
Voltage
3x120/70
Nominal diameter of complete cable mm
37
Nominal weight of cable kg/km
4342
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
120
Nominal thickness of insulation mm
1.2
Number of wires
3
Min. bending radius
During handling and installation, cable cm
44
In final installation, cable cm
31
During handling and installation, cable m
0.44
In final installation, cable m
0.31
Max. pulling force
Pulling-eye kN
18
Pulling-stocking kN
5.4
Resistance 20 °C Ω/km
0,153
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303344
Reka code
1146781
Nominal diameter of complete cable mm
37
Nominal weight of cable kg/km
4342
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
120
Nominal thickness of insulation mm
1.2
Number of wires
3
Min. bending radius
During handling and installation, cable cm
44
In final installation, cable cm
31
During handling and installation, cable m
0.44
In final installation, cable m
0.31
Max. pulling force
Pulling-eye kN
18
Pulling-stocking kN
5.4
Resistance 20 °C Ω/km
0,153
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303337
Reka code
1146781
3x150/70
Electric number
Size
Packaging
Voltage
3x150/70
Nominal diameter of complete cable mm
40
Nominal weight of cable kg/km
5196
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
150
Nominal thickness of insulation mm
1.4
Number of wires
3
Min. bending radius
During handling and installation, cable cm
48
In final installation, cable cm
34
During handling and installation, cable m
0.48
In final installation, cable m
0.34
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
6.8
Resistance 20 °C Ω/km
0,124
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303375
Reka code
1146782
Nominal diameter of complete cable mm
40
Nominal weight of cable kg/km
5196
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
150
Nominal thickness of insulation mm
1.4
Number of wires
3
Min. bending radius
During handling and installation, cable cm
48
In final installation, cable cm
34
During handling and installation, cable m
0.48
In final installation, cable m
0.34
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
6.8
Resistance 20 °C Ω/km
0,124
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303368
Reka code
1146782
3x185/95
Electric number
Size
Packaging
Voltage
3x185/95
Nominal diameter of complete cable mm
45
Nominal weight of cable kg/km
6650
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
185
Nominal thickness of insulation mm
1.6
Number of wires
3
Min. bending radius
During handling and installation, cable cm
54
In final installation, cable cm
38
During handling and installation, cable m
0.54
In final installation, cable m
0.38
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.3
Resistance 20 °C Ω/km
0,0991
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,193
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303405
Reka code
1146783
Nominal diameter of complete cable mm
45
Nominal weight of cable kg/km
6650
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
185
Nominal thickness of insulation mm
1.6
Number of wires
3
Min. bending radius
During handling and installation, cable cm
54
In final installation, cable cm
38
During handling and installation, cable m
0.54
In final installation, cable m
0.38
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.3
Resistance 20 °C Ω/km
0,0991
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,193
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303399
Reka code
1146783
3x240/120
Electric number
Size
Packaging
Voltage
3x240/120
Nominal diameter of complete cable mm
51
Nominal weight of cable kg/km
8645
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
240
Nominal thickness of insulation mm
1.7
Number of wires
3
Min. bending radius
During handling and installation, cable cm
61
In final installation, cable cm
43
During handling and installation, cable m
0.61
In final installation, cable m
0.43
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,0754
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,153
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303429
Reka code
1146784
3x300/150
Electric number
Size
Packaging
Voltage
3x300/150
Nominal diameter of complete cable mm
54
Nominal weight of cable kg/km
10683
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
300
Nominal thickness of insulation mm
1.8
Number of wires
3
Min. bending radius
During handling and installation, cable cm
65
In final installation, cable cm
45
During handling and installation, cable m
0.65
In final installation, cable m
0.45
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,0601
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,124
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303450
Reka code
1146785
4x35/16
Electric number
Size
Packaging
Voltage
4x35/16
Nominal diameter of complete cable mm
26
Nominal weight of cable kg/km
1746
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
0.9
Number of wires
4
Min. bending radius
During handling and installation, cable cm
31
In final installation, cable cm
22
During handling and installation, cable m
0.31
In final installation, cable m
0.22
Max. pulling force
Pulling-eye kN
7
Pulling-stocking kN
2.1
Resistance 20 °C Ω/km
0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303481
Reka code
1146794
Nominal diameter of complete cable mm
26
Nominal weight of cable kg/km
1746
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
0.9
Number of wires
4
Min. bending radius
During handling and installation, cable cm
31
In final installation, cable cm
22
During handling and installation, cable m
0.31
In final installation, cable m
0.22
Max. pulling force
Pulling-eye kN
7
Pulling-stocking kN
2.1
Resistance 20 °C Ω/km
0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303498
Reka code
1146794
4x50/25
Electric number
Size
Packaging
Voltage
4x50/25
Nominal diameter of complete cable mm
30
Nominal weight of cable kg/km
2372
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1
Number of wires
4
Min. bending radius
During handling and installation, cable cm
35
In final installation, cable cm
25
During handling and installation, cable m
0.35
In final installation, cable m
0.25
Max. pulling force
Pulling-eye kN
10
Pulling-stocking kN
3
Resistance 20 °C Ω/km
0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,727
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303528
Reka code
1146795
Nominal diameter of complete cable mm
30
Nominal weight of cable kg/km
2372
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1
Number of wires
4
Min. bending radius
During handling and installation, cable cm
35
In final installation, cable cm
25
During handling and installation, cable m
0.35
In final installation, cable m
0.25
Max. pulling force
Pulling-eye kN
10
Pulling-stocking kN
3
Resistance 20 °C Ω/km
0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,727
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303511
Reka code
1146795
4x70/35
Electric number
Size
Packaging
Voltage
4x70/35
Nominal diameter of complete cable mm
34
Nominal weight of cable kg/km
3258
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
70
Nominal thickness of insulation mm
1.1
Number of wires
4
Min. bending radius
During handling and installation, cable cm
41
In final installation, cable cm
29
During handling and installation, cable m
0.41
In final installation, cable m
0.29
Max. pulling force
Pulling-eye kN
14
Pulling-stocking kN
4.2
Resistance 20 °C Ω/km
0,268
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,524
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303542
Reka code
1146796
Nominal diameter of complete cable mm
34
Nominal weight of cable kg/km
3258
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
70
Nominal thickness of insulation mm
1.1
Number of wires
4
Min. bending radius
During handling and installation, cable cm
41
In final installation, cable cm
29
During handling and installation, cable m
0.41
In final installation, cable m
0.29
Max. pulling force
Pulling-eye kN
14
Pulling-stocking kN
4.2
Resistance 20 °C Ω/km
0,268
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,524
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303559
Reka code
1146796
4x95/50
Electric number
Size
Packaging
Voltage
4x95/50
Nominal diameter of complete cable mm
38
Nominal weight of cable kg/km
4405
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
95
Nominal thickness of insulation mm
1.1
Number of wires
4
Min. bending radius
During handling and installation, cable cm
45
In final installation, cable cm
32
During handling and installation, cable m
0.45
In final installation, cable m
0.32
Max. pulling force
Pulling-eye kN
19
Pulling-stocking kN
5.7
Resistance 20 °C Ω/km
0,193
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,387
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303580
Reka code
1146797
Nominal diameter of complete cable mm
38
Nominal weight of cable kg/km
4405
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
95
Nominal thickness of insulation mm
1.1
Number of wires
4
Min. bending radius
During handling and installation, cable cm
45
In final installation, cable cm
32
During handling and installation, cable m
0.45
In final installation, cable m
0.32
Max. pulling force
Pulling-eye kN
19
Pulling-stocking kN
5.7
Resistance 20 °C Ω/km
0,193
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,387
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303573
Reka code
1146797
4x120/70
Electric number
Size
Packaging
Voltage
4x120/70
Nominal diameter of complete cable mm
42
Nominal weight of cable kg/km
5558
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
120
Nominal thickness of insulation mm
1.2
Number of wires
4
Min. bending radius
During handling and installation, cable cm
50
In final installation, cable cm
35
During handling and installation, cable m
0.5
In final installation, cable m
0.35
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
7.2
Resistance 20 °C Ω/km
0,153
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303610
Reka code
1146798
Nominal diameter of complete cable mm
42
Nominal weight of cable kg/km
5558
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
120
Nominal thickness of insulation mm
1.2
Number of wires
4
Min. bending radius
During handling and installation, cable cm
50
In final installation, cable cm
35
During handling and installation, cable m
0.5
In final installation, cable m
0.35
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
7.2
Resistance 20 °C Ω/km
0,153
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303603
Reka code
1146798
4x150/70
Electric number
Size
Packaging
Voltage
4x150/70
Nominal diameter of complete cable mm
45
Nominal weight of cable kg/km
6699
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
150
Nominal thickness of insulation mm
1.4
Number of wires
4
Min. bending radius
During handling and installation, cable cm
55
In final installation, cable cm
38
During handling and installation, cable m
0.55
In final installation, cable m
0.38
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,124
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303641
Reka code
1146799
Nominal diameter of complete cable mm
45
Nominal weight of cable kg/km
6699
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
150
Nominal thickness of insulation mm
1.4
Number of wires
4
Min. bending radius
During handling and installation, cable cm
55
In final installation, cable cm
38
During handling and installation, cable m
0.55
In final installation, cable m
0.38
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,124
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303634
Reka code
1146799
4x185/95
Electric number
Size
Packaging
Voltage
4x185/95
Nominal diameter of complete cable mm
51
Nominal weight of cable kg/km
8523
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
185
Nominal thickness of insulation mm
1.6
Number of wires
4
Min. bending radius
During handling and installation, cable cm
61
In final installation, cable cm
43
During handling and installation, cable m
0.61
In final installation, cable m
0.43
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,0991
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,193
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303672
Reka code
1146800
Nominal diameter of complete cable mm
51
Nominal weight of cable kg/km
8523
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
185
Nominal thickness of insulation mm
1.6
Number of wires
4
Min. bending radius
During handling and installation, cable cm
61
In final installation, cable cm
43
During handling and installation, cable m
0.61
In final installation, cable m
0.43
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,0991
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,193
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303665
Reka code
1146800
4x240/120
Electric number
Size
Packaging
Voltage
4x240/120
Nominal diameter of complete cable mm
56
Nominal weight of cable kg/km
11033
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
240
Nominal thickness of insulation mm
1.7
Number of wires
4
Min. bending radius
During handling and installation, cable cm
68
In final installation, cable cm
47
During handling and installation, cable m
0.68
In final installation, cable m
0.47
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,0754
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,153
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303696
Reka code
1146801
4x300/150
Electric number
Size
Packaging
Voltage
4x300/150
Nominal diameter of complete cable mm
61
Nominal weight of cable kg/km
13688
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
300
Nominal thickness of insulation mm
1.8
Number of wires
4
Min. bending radius
During handling and installation, cable cm
73
In final installation, cable cm
51
During handling and installation, cable m
0.73
In final installation, cable m
0.51
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,0601
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,124
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176303726
Reka code
1146802