MMJ

Cables may be used for fixed installations, indoor, outdoor, on surface or inlaid in conduits and canals. Not to be laid in soil nor directly in cast concrete. Can be used in direct sunlight. Self extinguishing, no after-burning.

Standards SFS 2091:2011, SS 424 02 19-3, NEK 535
Reaction to fire Eca
CPR - DoP 2017010_DOP.pdf
Conductor Circular solid copper, EN/IEC 60228 class 1
Insulation PVC-compound
Core Identification (all color combinations in the cable family) Blue, brown
Brown, black, grey
Blue, brown, black, grey
Blue, brown, black, grey, black
Yellow-green, blue, brown
Yellow-green, blue, brown, black
Yellow-green, blue, brown, black, grey
Inner covering Filling compound
Separation sheath Filling compound
Oversheath UV-resistant PVC-compound
Colour of the oversheath White

2x1,5 N

Electric number Size Packing (m) Voltage

2x1,5 N

Nominal diameter of complete cable (mm) 8
Nominal weight of cable (kg/km) 92
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Nominal diameter over the insulation without insulation screen (mm) 88
Number of wires 2
Nominal diameter of earth conductor (mm) 88
Bending radius
During handling and installation, cable (cm) 80
In final installation, cable (cm) 24
During handling and installation, phase conductor (cm) 88
In final installation, phase conductor (cm) 88
During handling and installation, phase conductor (cm) 88
During handling and installation, cable (cm) 8
In final installation, phase conductor (cm) 88
In final installation, cable (cm) 2
During handling and installation, phase conductor (m) 88
During handling and installation, cable (m) 0.09
In final installation, phase conductor (m) 88
In final installation, cable (m) 0.027
Pulling force
Pulling-eye (kN) 0.15
Pulling-stocking (kN) 88
Resistance 20 °C (ohm/km) 12.1
Maximum d.c. resistance at 20 °C, metal screen (ohm/km) 88
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.1725
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004068120
Reka code 1102005
Nominal diameter of complete cable (mm) 8
Nominal weight of cable (kg/km) 92
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Nominal diameter over the insulation without insulation screen (mm) 88
Number of wires 2
Nominal diameter of earth conductor (mm) 88
Bending radius
During handling and installation, cable (cm) 80
In final installation, cable (cm) 24
During handling and installation, phase conductor (cm) 88
In final installation, phase conductor (cm) 88
During handling and installation, phase conductor (cm) 88
During handling and installation, cable (cm) 8
In final installation, phase conductor (cm) 88
In final installation, cable (cm) 2
During handling and installation, phase conductor (m) 88
During handling and installation, cable (m) 0.09
In final installation, phase conductor (m) 88
In final installation, cable (m) 0.027
Pulling force
Pulling-eye (kN) 0.15
Pulling-stocking (kN) 88
Resistance 20 °C (ohm/km) 12.1
Maximum d.c. resistance at 20 °C, metal screen (ohm/km) 88
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.1725
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004568149
Reka code 1102005
Nominal diameter of complete cable (mm) 8
Nominal weight of cable (kg/km) 92
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Nominal diameter over the insulation without insulation screen (mm) 88
Number of wires 2
Nominal diameter of earth conductor (mm) 88
Bending radius
During handling and installation, cable (cm) 80
In final installation, cable (cm) 24
During handling and installation, phase conductor (cm) 88
In final installation, phase conductor (cm) 88
During handling and installation, phase conductor (cm) 88
During handling and installation, cable (cm) 8
In final installation, phase conductor (cm) 88
In final installation, cable (cm) 2
During handling and installation, phase conductor (m) 88
During handling and installation, cable (m) 0.09
In final installation, phase conductor (m) 88
In final installation, cable (m) 0.027
Pulling force
Pulling-eye (kN) 0.15
Pulling-stocking (kN) 88
Resistance 20 °C (ohm/km) 12.1
Maximum d.c. resistance at 20 °C, metal screen (ohm/km) 88
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.1725
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004568163
Reka code 1102005
Nominal diameter of complete cable (mm) 8
Nominal weight of cable (kg/km) 92
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Nominal diameter over the insulation without insulation screen (mm) 88
Number of wires 2
Nominal diameter of earth conductor (mm) 88
Bending radius
During handling and installation, cable (cm) 80
In final installation, cable (cm) 24
During handling and installation, phase conductor (cm) 88
In final installation, phase conductor (cm) 88
During handling and installation, phase conductor (cm) 88
During handling and installation, cable (cm) 8
In final installation, phase conductor (cm) 88
In final installation, cable (cm) 2
During handling and installation, phase conductor (m) 88
During handling and installation, cable (m) 0.09
In final installation, phase conductor (m) 88
In final installation, cable (m) 0.027
Pulling force
Pulling-eye (kN) 0.15
Pulling-stocking (kN) 88
Resistance 20 °C (ohm/km) 12.1
Maximum d.c. resistance at 20 °C, metal screen (ohm/km) 88
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.1725
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004568125
Reka code 1102005
Nominal diameter of complete cable (mm) 8
Nominal weight of cable (kg/km) 92
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Nominal diameter over the insulation without insulation screen (mm) 88
Number of wires 2
Nominal diameter of earth conductor (mm) 88
Bending radius
During handling and installation, cable (cm) 80
In final installation, cable (cm) 24
During handling and installation, phase conductor (cm) 88
In final installation, phase conductor (cm) 88
During handling and installation, phase conductor (cm) 88
During handling and installation, cable (cm) 8
In final installation, phase conductor (cm) 88
In final installation, cable (cm) 2
During handling and installation, phase conductor (m) 88
During handling and installation, cable (m) 0.09
In final installation, phase conductor (m) 88
In final installation, cable (m) 0.027
Pulling force
Pulling-eye (kN) 0.15
Pulling-stocking (kN) 88
Resistance 20 °C (ohm/km) 12.1
Maximum d.c. resistance at 20 °C, metal screen (ohm/km) 88
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.1725
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004568156
Reka code 1102005

2x2,5 N

Electric number Size Packing (m) Voltage

2x2,5 N

Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 132
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 2
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.2875
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004068137
Reka code 1102010
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 132
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 2
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.2875
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6438176001905
Reka code 1102010
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 132
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 2
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.2875
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004568132
Reka code 1102010

3x1,5

Electric number Size Packing (m) Voltage

3x1,5

Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 109
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.23
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004068229
Reka code 1102006
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 109
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.23
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004568224
Reka code 1102006

4x1,5 N

Electric number Size Packing (m) Voltage

4x1,5 N

Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 133
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004068328
Reka code 1102007
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 133
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004068335
Reka code 1102007
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 133
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004568323
Reka code 1102007

5x1,5 N

Electric number Size Packing (m) Voltage

5x1,5 N

Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 156
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004068427
Reka code 1102008
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 156
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004068434
Reka code 1102008
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 156
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004068441
Reka code 1102008
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 156
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004568422
Reka code 1102008

3x1,5 S

Electric number Size Packing (m) Voltage

3x1,5 S

Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 109
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.23
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069707
Reka code 1102106
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 109
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.23
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 8410004069707
Reka code 1102106
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 109
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.23
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069226
Reka code 1102106
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 109
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.23
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569122
Reka code 1102106
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 109
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.23
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6438176001837
Reka code 1102106
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 109
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.23
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569771
Reka code 1102106
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 109
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.23
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569818
Reka code 1102106
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 109
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.23
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569221
Reka code 1102106

3x2,5 S

Electric number Size Packing (m) Voltage

3x2,5 S

Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 158
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069714
Reka code 1102111
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 158
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069233
Reka code 1102111
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 158
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6438176001899
Reka code 1102111
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 158
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569788
Reka code 1102111
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 158
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569825
Reka code 1102111
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 158
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569238
Reka code 1102111
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 158
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569139
Reka code 1102111
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 158
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6438176304136
Reka code 1102111

4x1,5 S

Electric number Size Packing (m) Voltage

4x1,5 S

Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 133
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069349
Reka code 1102107
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 133
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069325
Reka code 1102107
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 133
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569146
Reka code 1102107
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 133
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569795
Reka code 1102107
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 133
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 90
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.1
In final installation, cable (m) 0.03
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569320
Reka code 1102107

4x2,5 S

Electric number Size Packing (m) Voltage

4x2,5 S

Nominal diameter of complete cable (mm) 11
Nominal weight of cable (kg/km) 193
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 110
In final installation, cable (cm) 33
During handling and installation, cable (cm) 11
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.12
In final installation, cable (m) 0.036
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6438176001998
Reka code 1102112
Nominal diameter of complete cable (mm) 11
Nominal weight of cable (kg/km) 193
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 110
In final installation, cable (cm) 33
During handling and installation, cable (cm) 11
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.12
In final installation, cable (m) 0.036
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069332
Reka code 1102112
Nominal diameter of complete cable (mm) 11
Nominal weight of cable (kg/km) 193
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 110
In final installation, cable (cm) 33
During handling and installation, cable (cm) 11
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.12
In final installation, cable (m) 0.036
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569153
Reka code 1102112
Nominal diameter of complete cable (mm) 11
Nominal weight of cable (kg/km) 193
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 110
In final installation, cable (cm) 33
During handling and installation, cable (cm) 11
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.12
In final installation, cable (m) 0.036
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569801
Reka code 1102112
Nominal diameter of complete cable (mm) 11
Nominal weight of cable (kg/km) 193
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 110
In final installation, cable (cm) 33
During handling and installation, cable (cm) 11
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.12
In final installation, cable (m) 0.036
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569337
Reka code 1102112
Nominal diameter of complete cable (mm) 11
Nominal weight of cable (kg/km) 193
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 4
Bending radius
During handling and installation, cable (cm) 110
In final installation, cable (cm) 33
During handling and installation, cable (cm) 11
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.12
In final installation, cable (m) 0.036
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569344
Reka code 1102112

5x1,5 S

Electric number Size Packing (m) Voltage

5x1,5 S

Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 156
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069905
Reka code 1102108
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 156
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069424
Reka code 1102108
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 156
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569160
Reka code 1102108
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 156
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569948
Reka code 1102108
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 156
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569856
Reka code 1102108
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 156
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 100
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
During handling and installation, cable (m) 0.11
In final installation, cable (m) 0.033
Pulling force
Pulling-eye (kN) 0.38
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569429
Reka code 1102108

5x2,5 S

Electric number Size Packing (m) Voltage

5x2,5 S

Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 229
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 120
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
During handling and installation, cable (m) 0.13
In final installation, cable (m) 0.039
Pulling force
Pulling-eye (kN) 0.63
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069431
Reka code 1102113
Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 229
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 120
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
During handling and installation, cable (m) 0.13
In final installation, cable (m) 0.039
Pulling force
Pulling-eye (kN) 0.63
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6438176002117
Reka code 1102113
Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 229
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 120
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
During handling and installation, cable (m) 0.13
In final installation, cable (m) 0.039
Pulling force
Pulling-eye (kN) 0.63
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569177
Reka code 1102113
Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 229
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 120
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
During handling and installation, cable (m) 0.13
In final installation, cable (m) 0.039
Pulling force
Pulling-eye (kN) 0.63
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569955
Reka code 1102113
Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 229
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 120
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
During handling and installation, cable (m) 0.13
In final installation, cable (m) 0.039
Pulling force
Pulling-eye (kN) 0.63
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569887
Reka code 1102113
Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 229
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 120
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
During handling and installation, cable (m) 0.13
In final installation, cable (m) 0.039
Pulling force
Pulling-eye (kN) 0.63
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569436
Reka code 1102113
Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 229
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 120
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
During handling and installation, cable (m) 0.13
In final installation, cable (m) 0.039
Pulling force
Pulling-eye (kN) 0.63
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569443
Reka code 1102113

3x6 S

Electric number Size Packing (m) Voltage

3x6 S

Nominal diameter of complete cable (mm) 14
Nominal weight of cable (kg/km) 339
Conductor material Copper
Nominal diameter of conductor (mm) 3.15
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 140
In final installation, cable (cm) 42
During handling and installation, cable (cm) 14
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 0.9
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.08
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069257
Reka code 1102121
Nominal diameter of complete cable (mm) 14
Nominal weight of cable (kg/km) 339
Conductor material Copper
Nominal diameter of conductor (mm) 3.15
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 140
In final installation, cable (cm) 42
During handling and installation, cable (cm) 14
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 0.9
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.08
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569252
Reka code 1102121
Nominal diameter of complete cable (mm) 14
Nominal weight of cable (kg/km) 339
Conductor material Copper
Nominal diameter of conductor (mm) 3.15
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 140
In final installation, cable (cm) 42
During handling and installation, cable (cm) 14
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 0.9
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.08
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069271
Reka code 1102121

3x10 S

Electric number Size Packing (m) Voltage

3x10 S

Nominal diameter of complete cable (mm) 17
Nominal weight of cable (kg/km) 515
Conductor material Copper
Nominal diameter of conductor (mm) 4.05
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 170
In final installation, cable (cm) 51
During handling and installation, cable (cm) 17
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 1.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.83
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 1.15
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6438176002193
Reka code 1102126
Nominal diameter of complete cable (mm) 17
Nominal weight of cable (kg/km) 515
Conductor material Copper
Nominal diameter of conductor (mm) 4.05
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 3
Bending radius
During handling and installation, cable (cm) 170
In final installation, cable (cm) 51
During handling and installation, cable (cm) 17
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 1.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.83
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 1.15
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069264
Reka code 1102126

5x6 S

Electric number Size Packing (m) Voltage

5x6 S

Nominal diameter of complete cable (mm) 16
Nominal weight of cable (kg/km) 514
Conductor material Copper
Nominal diameter of conductor (mm) 3.15
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 160
In final installation, cable (cm) 48
During handling and installation, cable (cm) 16
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 1.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.08
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004570104
Reka code 1102123
Nominal diameter of complete cable (mm) 16
Nominal weight of cable (kg/km) 514
Conductor material Copper
Nominal diameter of conductor (mm) 3.15
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 160
In final installation, cable (cm) 48
During handling and installation, cable (cm) 16
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 1.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.08
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569450
Reka code 1102123
Nominal diameter of complete cable (mm) 16
Nominal weight of cable (kg/km) 514
Conductor material Copper
Nominal diameter of conductor (mm) 3.15
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 160
In final installation, cable (cm) 48
During handling and installation, cable (cm) 16
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 1.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.08
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569474
Reka code 1102123
Nominal diameter of complete cable (mm) 16
Nominal weight of cable (kg/km) 514
Conductor material Copper
Nominal diameter of conductor (mm) 3.15
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 160
In final installation, cable (cm) 48
During handling and installation, cable (cm) 16
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 1.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.08
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004569467
Reka code 1102123
Nominal diameter of complete cable (mm) 16
Nominal weight of cable (kg/km) 514
Conductor material Copper
Nominal diameter of conductor (mm) 3.15
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 160
In final installation, cable (cm) 48
During handling and installation, cable (cm) 16
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 1.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.08
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069455
Reka code 1102123

5x10 S

Electric number Size Packing (m) Voltage

5x10 S

Nominal diameter of complete cable (mm) 20
Nominal weight of cable (kg/km) 817
Conductor material Copper
Nominal diameter of conductor (mm) 4.05
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 200
In final installation, cable (cm) 60
During handling and installation, cable (cm) 20
In final installation, cable (cm) 6
Pulling force
Pulling-eye (kN) 2.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.83
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 1.15
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069462
Reka code 1102128
Nominal diameter of complete cable (mm) 20
Nominal weight of cable (kg/km) 817
Conductor material Copper
Nominal diameter of conductor (mm) 4.05
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 200
In final installation, cable (cm) 60
During handling and installation, cable (cm) 20
In final installation, cable (cm) 6
Pulling force
Pulling-eye (kN) 2.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.83
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 1.15
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069400
Reka code 1102128

5x16 S

Electric number Size Packing (m) Voltage

5x16 S

Nominal diameter of complete cable (mm) 23
Nominal weight of cable (kg/km) 1111
Conductor material Copper
Nominal diameter of conductor (mm) 5.04
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 230
In final installation, cable (cm) 69
During handling and installation, cable (cm) 23
In final installation, cable (cm) 7
Pulling force
Pulling-eye (kN) 4
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.15
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 1.84
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069479
Reka code 1102133
Nominal diameter of complete cable (mm) 23
Nominal weight of cable (kg/km) 1111
Conductor material Copper
Nominal diameter of conductor (mm) 5.04
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 230
In final installation, cable (cm) 69
During handling and installation, cable (cm) 23
In final installation, cable (cm) 7
Pulling force
Pulling-eye (kN) 4
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.15
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 1.84
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069417
Reka code 1102133

5x25 S

Electric number Size Packing (m) Voltage

5x25 S

Nominal diameter of complete cable (mm) 29
Nominal weight of cable (kg/km) 1914
Conductor material Copper
Nominal diameter of conductor (mm) 6.39
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 290
In final installation, cable (cm) 87
During handling and installation, cable (cm) 29
In final installation, cable (cm) 9
Pulling force
Pulling-eye (kN) 6.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.727
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 2.88
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004069486
Reka code 1102138
Nominal diameter of complete cable (mm) 29
Nominal weight of cable (kg/km) 1914
Conductor material Copper
Nominal diameter of conductor (mm) 6.39
Nominal cross-sectional area of conductor (mm2) 0
Number of wires 5
Bending radius
During handling and installation, cable (cm) 290
In final installation, cable (cm) 87
During handling and installation, cable (cm) 29
In final installation, cable (cm) 9
Pulling force
Pulling-eye (kN) 6.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.727
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 2.88
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6438176002315