ML

Conductor may be laid indoors. For fixed installation in conduits, for fixed internal wiring in electrical equipments.

Standards EN 50525-2-31:2011
Reaction to fire Eca
CPR - DoP 2017040_DOP.pdf
Conductor Circular solid copper, EN/IEC 60228 class 1
Insulation PVC-compound
Core Identification (all color combinations in the cable family) Yellow-green
blue
brown
black
grey

1,5 GY H07V-U

Electric number Size Packing (m) Voltage

1,5 GY H07V-U

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004018002
Reka code 1101010

1,5 BN H07V-U

Electric number Size Packing (m) Voltage

1,5 BN H07V-U

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004018026
Reka code 1101012

1,5 BK H07V-U

Electric number Size Packing (m) Voltage

1,5 BK H07V-U

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004018033
Reka code 1101013

1,5 BU H07V-U

Electric number Size Packing (m) Voltage

1,5 BU H07V-U

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004018071
Reka code 1101017

1,5 GNYE H07V-U

Electric number Size Packing (m) Voltage

1,5 GNYE H07V-U

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.36
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 12.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004018088
Reka code 1101018

2,5 GY H07V-U

Electric number Size Packing (m) Voltage

2,5 GY H07V-U

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 30
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.13
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004018200
Reka code 1101020

2,5 BN H07V-U

Electric number Size Packing (m) Voltage

2,5 BN H07V-U

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 30
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.13
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004018224
Reka code 1101022

2,5 BK H07V-U

Electric number Size Packing (m) Voltage

2,5 BK H07V-U

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 30
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.13
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004018231
Reka code 1101023

2,5 BU H07V-U

Electric number Size Packing (m) Voltage

2,5 BU H07V-U

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 30
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.13
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004018279
Reka code 1101027

2,5 GNYE H07V-U

Electric number Size Packing (m) Voltage

2,5 GNYE H07V-U

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 30
Conductor material Copper
Nominal diameter of conductor (mm) 1.74
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.13
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.41
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 70
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004018286
Reka code 1101028