ML-HF / H07Z1-U
Download product group datasheet
Installation wirefor fixed installations indoors. For internal wiring of electrical devices. The conductor insulation must be protected against UV-radiation. The cable is halogen-free and flame-retardant according to CPR-class Dca-s2,d2,a2.
Standards | EN 50525-3-31 |
---|---|
Reaction to fire | Dca-s2,d2,a2 |
CPR - DoP | 2017043_DOP.pdf |
Conductor | Circular solid copper, EN/IEC 60228 class 1 |
Insulation | Halogen free polyolefine compound |
Core Identification (all color combinations in the cable family) | Yellowgreen Blue Brown Black Grey Orange Red White |
1,5 GY H07Z1-U TYPE 2
Electric number
Size
Packaging
Voltage
1,5 GY H07Z1-U TYPE 2
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
20
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
22
In final installation, cable mm
8
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223314
Reka code
1145840
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
20
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
22
In final installation, cable mm
8
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006238
Reka code
1145840
1,5 BN H07Z1-U TYPE 2
Electric number
Size
Packaging
Voltage
1,5 BN H07Z1-U TYPE 2
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
20
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
22
In final installation, cable mm
8
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223284
Reka code
1145842
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
20
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
22
In final installation, cable mm
8
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006245
Reka code
1145842
1,5 BK H07Z1-U TYPE 2
Electric number
Size
Packaging
Voltage
1,5 BK H07Z1-U TYPE 2
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
20
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
22
In final installation, cable mm
8
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223291
Reka code
1145843
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
20
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
22
In final installation, cable mm
8
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006252
Reka code
1145843
1,5 BU H07Z1-U TYPE 2
Electric number
Size
Packaging
Voltage
1,5 BU H07Z1-U TYPE 2
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
20
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
22
In final installation, cable mm
8
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223277
Reka code
1145847
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
20
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
22
In final installation, cable mm
8
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006269
Reka code
1145847
1,5 GNYE H07Z1-U TYPE 2
Electric number
Size
Packaging
Voltage
1,5 GNYE H07Z1-U TYPE 2
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
20
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
22
In final installation, cable mm
8
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223260
Reka code
1145848
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
20
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
22
In final installation, cable mm
8
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006276
Reka code
1145848
2,5 GY H07Z1-U TYPE 2
Electric number
Size
Packaging
Voltage
2,5 GY H07Z1-U TYPE 2
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
31
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
27
In final installation, cable mm
10
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006283
Reka code
1145570
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
31
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
27
In final installation, cable mm
10
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223383
Reka code
1145570
2,5 BN H07Z1-U TYPE 2
Electric number
Size
Packaging
Voltage
2,5 BN H07Z1-U TYPE 2
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
31
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
27
In final installation, cable mm
10
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006290
Reka code
1145572
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
31
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
27
In final installation, cable mm
10
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223352
Reka code
1145572
2,5 BK H07Z1-U TYPE 2
Electric number
Size
Packaging
Voltage
2,5 BK H07Z1-U TYPE 2
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
31
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
27
In final installation, cable mm
10
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223369
Reka code
1145573
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
31
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
27
In final installation, cable mm
10
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006306
Reka code
1145573
2,5 BU H07Z1-U TYPE 2
Electric number
Size
Packaging
Voltage
2,5 BU H07Z1-U TYPE 2
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
31
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
27
In final installation, cable mm
10
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006313
Reka code
1145577
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
31
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
27
In final installation, cable mm
10
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223345
Reka code
1145577
2,5 GNYE H07Z1-U TYPE 2
Electric number
Size
Packaging
Voltage
2,5 GNYE H07Z1-U TYPE 2
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
31
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
27
In final installation, cable mm
10
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223338
Reka code
1145578
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
31
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
27
In final installation, cable mm
10
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006320
Reka code
1145578