ML-HF / H07Z1-U

Download product group datasheet

Installation wirefor fixed installations indoors. For internal wiring of electrical devices. The conductor insulation must be protected against UV-radiation. The cable is halogen-free and flame-retardant according to CPR-class Dca-s2,d2,a2.

Standards EN 50525-3-31
Reaction to fire Dca-s2,d2,a2
CPR - DoP 2017043_DOP.pdf
Conductor Circular solid copper, EN/IEC 60228 class 1
Insulation Halogen free polyolefine compound
Core Identification (all color combinations in the cable family) Yellowgreen
Blue
Brown
Black
Grey
Orange
Red
White

1,5 GY H07Z1-U TYPE 2

Electric number Size Packaging Voltage

1,5 GY H07Z1-U TYPE 2

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 20
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 22
In final installation, cable mm 8
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223314
Reka code 1145840
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 20
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 22
In final installation, cable mm 8
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176006238
Reka code 1145840

1,5 BN H07Z1-U TYPE 2

Electric number Size Packaging Voltage

1,5 BN H07Z1-U TYPE 2

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 20
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 22
In final installation, cable mm 8
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223284
Reka code 1145842
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 20
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 22
In final installation, cable mm 8
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176006245
Reka code 1145842

1,5 BK H07Z1-U TYPE 2

Electric number Size Packaging Voltage

1,5 BK H07Z1-U TYPE 2

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 20
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 22
In final installation, cable mm 8
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223291
Reka code 1145843
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 20
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 22
In final installation, cable mm 8
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176006252
Reka code 1145843

1,5 BU H07Z1-U TYPE 2

Electric number Size Packaging Voltage

1,5 BU H07Z1-U TYPE 2

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 20
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 22
In final installation, cable mm 8
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223277
Reka code 1145847
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 20
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 22
In final installation, cable mm 8
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176006269
Reka code 1145847

1,5 GNYE H07Z1-U TYPE 2

Electric number Size Packaging Voltage

1,5 GNYE H07Z1-U TYPE 2

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 20
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 22
In final installation, cable mm 8
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223260
Reka code 1145848
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 20
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 22
In final installation, cable mm 8
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176006276
Reka code 1145848

2,5 GY H07Z1-U TYPE 2

Electric number Size Packaging Voltage

2,5 GY H07Z1-U TYPE 2

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 31
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 27
In final installation, cable mm 10
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176006283
Reka code 1145570
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 31
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 27
In final installation, cable mm 10
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223383
Reka code 1145570

2,5 BN H07Z1-U TYPE 2

Electric number Size Packaging Voltage

2,5 BN H07Z1-U TYPE 2

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 31
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 27
In final installation, cable mm 10
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176006290
Reka code 1145572
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 31
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 27
In final installation, cable mm 10
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223352
Reka code 1145572

2,5 BK H07Z1-U TYPE 2

Electric number Size Packaging Voltage

2,5 BK H07Z1-U TYPE 2

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 31
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 27
In final installation, cable mm 10
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223369
Reka code 1145573
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 31
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 27
In final installation, cable mm 10
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176006306
Reka code 1145573

2,5 BU H07Z1-U TYPE 2

Electric number Size Packaging Voltage

2,5 BU H07Z1-U TYPE 2

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 31
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 27
In final installation, cable mm 10
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176006313
Reka code 1145577
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 31
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 27
In final installation, cable mm 10
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223345
Reka code 1145577

2,5 GNYE H07Z1-U TYPE 2

Electric number Size Packaging Voltage

2,5 GNYE H07Z1-U TYPE 2

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 31
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 27
In final installation, cable mm 10
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223338
Reka code 1145578
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 31
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 27
In final installation, cable mm 10
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176006320
Reka code 1145578