MKEM 90 (H07V2-K)

Download product group datasheet

Installation wirefor fixed installations indoors. For internal wiring of electrical devices. Maximum conductor temperature in normal operation 90 °C. The conductor insulation must be protected against UV-radiation. The cable is flame-retardant according to CPR-class Eca.

Standards EN 50525-2-31:2011
Reaction to fire Eca
CPR - DoP 2017042_DOP.pdf
Conductor Circular flexible copper, EN/IEC 60228 class 5
Insulation PVC-compound
Core Identification (all color combinations in the cable family) Yellow-green
blue
brown
black
gray
Red

1,5 GY H07V2-K

Electric number Size Packaging Voltage

1,5 GY H07V2-K

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 19
Conductor material Copper
Nominal diameter of conductor mm 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 13.3
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038000
Reka code 1101820

1,5 BN H07V2-K

Electric number Size Packaging Voltage

1,5 BN H07V2-K

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 19
Conductor material Copper
Nominal diameter of conductor mm 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 13.3
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038024
Reka code 1101822

1,5 BK H07V2-K

Electric number Size Packaging Voltage

1,5 BK H07V2-K

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 19
Conductor material Copper
Nominal diameter of conductor mm 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 13.3
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541630
Reka code 1101823
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 19
Conductor material Copper
Nominal diameter of conductor mm 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 13.3
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541531
Reka code 1101823
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 19
Conductor material Copper
Nominal diameter of conductor mm 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 13.3
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038031
Reka code 1101823

1,5 BU H07V2-K

Electric number Size Packaging Voltage

1,5 BU H07V2-K

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 19
Conductor material Copper
Nominal diameter of conductor mm 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 13.3
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541371
Reka code 1101827
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 19
Conductor material Copper
Nominal diameter of conductor mm 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 13.3
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541272
Reka code 1101827
Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 19
Conductor material Copper
Nominal diameter of conductor mm 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 13.3
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038079
Reka code 1101827

1,5 GNYE H07V2-K

Electric number Size Packaging Voltage

1,5 GNYE H07V2-K

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 19
Conductor material Copper
Nominal diameter of conductor mm 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 13.3
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038086
Reka code 1101828

2,5 BK H07V2-K

Electric number Size Packaging Voltage

2,5 BK H07V2-K

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 28
Conductor material Copper
Nominal diameter of conductor mm 2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 32
In final installation, cable mm 12
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.98
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541838
Reka code 1101833
Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 28
Conductor material Copper
Nominal diameter of conductor mm 2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 32
In final installation, cable mm 12
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.98
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038239
Reka code 1101833

2,5 BU H07V2-K

Electric number Size Packaging Voltage

2,5 BU H07V2-K

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 28
Conductor material Copper
Nominal diameter of conductor mm 2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 32
In final installation, cable mm 12
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.98
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038277
Reka code 1101837
Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 28
Conductor material Copper
Nominal diameter of conductor mm 2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 32
In final installation, cable mm 12
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.98
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541470
Reka code 1101837

2,5 GNYE H07V2-K

Electric number Size Packaging Voltage

2,5 GNYE H07V2-K

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 28
Conductor material Copper
Nominal diameter of conductor mm 2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 32
In final installation, cable mm 12
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7.98
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038284
Reka code 1101838

4 BN H07V2-K

Electric number Size Packaging Voltage

4 BN H07V2-K

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 44
Conductor material Copper
Nominal diameter of conductor mm 2.4
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 32
In final installation, cable mm 12
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0
Resistance 20 °C Ω/km 4.95
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038420
Reka code 1101842

4 BK H07V2-K

Electric number Size Packaging Voltage

4 BK H07V2-K

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 44
Conductor material Copper
Nominal diameter of conductor mm 2.4
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 32
In final installation, cable mm 12
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0
Resistance 20 °C Ω/km 4.95
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542033
Reka code 1101843
Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 44
Conductor material Copper
Nominal diameter of conductor mm 2.4
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 32
In final installation, cable mm 12
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0
Resistance 20 °C Ω/km 4.95
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038437
Reka code 1101843

4 BU H07V2-K

Electric number Size Packaging Voltage

4 BU H07V2-K

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 44
Conductor material Copper
Nominal diameter of conductor mm 2.4
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 32
In final installation, cable mm 12
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0
Resistance 20 °C Ω/km 4.95
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038475
Reka code 1101847

4 GNYE H07V2-K

Electric number Size Packaging Voltage

4 GNYE H07V2-K

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 44
Conductor material Copper
Nominal diameter of conductor mm 2.4
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 32
In final installation, cable mm 12
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0
Resistance 20 °C Ω/km 4.95
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038482
Reka code 1101848

6 BN H07V2-K

Electric number Size Packaging Voltage

6 BN H07V2-K

Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 59
Conductor material Copper
Nominal diameter of conductor mm 3.2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 40
In final installation, cable mm 15
During handling and installation, cable cm 4
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3.30
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004540121
Reka code 1101852
Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 59
Conductor material Copper
Nominal diameter of conductor mm 3.2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 40
In final installation, cable mm 15
During handling and installation, cable cm 4
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3.30
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038628
Reka code 1101852

6 BK H07V2-K

Electric number Size Packaging Voltage

6 BK H07V2-K

Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 59
Conductor material Copper
Nominal diameter of conductor mm 3.2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 40
In final installation, cable mm 15
During handling and installation, cable cm 4
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3.30
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542231
Reka code 1101853
Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 59
Conductor material Copper
Nominal diameter of conductor mm 3.2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 40
In final installation, cable mm 15
During handling and installation, cable cm 4
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3.30
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038635
Reka code 1101853
Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 59
Conductor material Copper
Nominal diameter of conductor mm 3.2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 40
In final installation, cable mm 15
During handling and installation, cable cm 4
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3.30
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542132
Reka code 1101853

6 BU H07V2-K

Electric number Size Packaging Voltage

6 BU H07V2-K

Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 59
Conductor material Copper
Nominal diameter of conductor mm 3.2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 40
In final installation, cable mm 15
During handling and installation, cable cm 4
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3.30
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541678
Reka code 1101857
Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 59
Conductor material Copper
Nominal diameter of conductor mm 3.2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 40
In final installation, cable mm 15
During handling and installation, cable cm 4
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3.30
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541579
Reka code 1101857
Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 59
Conductor material Copper
Nominal diameter of conductor mm 3.2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 40
In final installation, cable mm 15
During handling and installation, cable cm 4
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3.30
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038673
Reka code 1101857

6 GNYE H07V2-K

Electric number Size Packaging Voltage

6 GNYE H07V2-K

Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 59
Conductor material Copper
Nominal diameter of conductor mm 3.2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 40
In final installation, cable mm 15
During handling and installation, cable cm 4
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3.30
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038680
Reka code 1101858
Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 59
Conductor material Copper
Nominal diameter of conductor mm 3.2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 40
In final installation, cable mm 15
During handling and installation, cable cm 4
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3.30
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542286
Reka code 1101858
Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 59
Conductor material Copper
Nominal diameter of conductor mm 3.2
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 40
In final installation, cable mm 15
During handling and installation, cable cm 4
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3.30
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542187
Reka code 1101858

10 GY H07V2-K

Electric number Size Packaging Voltage

10 GY H07V2-K

Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal diameter of conductor mm 4.2
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.91
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038802
Reka code 1101860

10 BN H07V2-K

Electric number Size Packaging Voltage

10 BN H07V2-K

Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal diameter of conductor mm 4.2
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.91
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038826
Reka code 1101862

10 BK H07V2-K

Electric number Size Packaging Voltage

10 BK H07V2-K

Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal diameter of conductor mm 4.2
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.91
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004538838
Reka code 1101863
Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal diameter of conductor mm 4.2
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.91
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038833
Reka code 1101863

10 BU H07V2-K

Electric number Size Packaging Voltage

10 BU H07V2-K

Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal diameter of conductor mm 4.2
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.91
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038871
Reka code 1101867
Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal diameter of conductor mm 4.2
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.91
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004538876
Reka code 1101867

10 GNYE H07V2-K

Electric number Size Packaging Voltage

10 GNYE H07V2-K

Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal diameter of conductor mm 4.2
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.91
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004538883
Reka code 1101868
Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal diameter of conductor mm 4.2
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.91
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004038888
Reka code 1101868

16 BK H07V2-K

Electric number Size Packaging Voltage

16 BK H07V2-K

Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 164
Conductor material Copper
Nominal diameter of conductor mm 5.1
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 56
In final installation, cable mm 21
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.21
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039038
Reka code 1101873
Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 164
Conductor material Copper
Nominal diameter of conductor mm 5.1
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 56
In final installation, cable mm 21
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.21
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539033
Reka code 1101873
Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 164
Conductor material Copper
Nominal diameter of conductor mm 5.1
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 56
In final installation, cable mm 21
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.21
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542330
Reka code 1101873

16 BU H07V2-K

Electric number Size Packaging Voltage

16 BU H07V2-K

Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 164
Conductor material Copper
Nominal diameter of conductor mm 5.1
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 56
In final installation, cable mm 21
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.21
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541777
Reka code 1101877
Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 164
Conductor material Copper
Nominal diameter of conductor mm 5.1
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 56
In final installation, cable mm 21
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.21
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539071
Reka code 1101877
Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 164
Conductor material Copper
Nominal diameter of conductor mm 5.1
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 56
In final installation, cable mm 21
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.21
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039076
Reka code 1101877

16 GNYE H07V2-K

Electric number Size Packaging Voltage

16 GNYE H07V2-K

Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 164
Conductor material Copper
Nominal diameter of conductor mm 5.1
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 56
In final installation, cable mm 21
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.21
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542385
Reka code 1101878
Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 164
Conductor material Copper
Nominal diameter of conductor mm 5.1
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 56
In final installation, cable mm 21
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.21
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539088
Reka code 1101878
Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 164
Conductor material Copper
Nominal diameter of conductor mm 5.1
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 56
In final installation, cable mm 21
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1.21
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039083
Reka code 1101878

25 BK H07V2-K

Electric number Size Packaging Voltage

25 BK H07V2-K

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 251
Conductor material Copper
Nominal diameter of conductor mm 6.3
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 72
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.780
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542439
Reka code 1101883
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 251
Conductor material Copper
Nominal diameter of conductor mm 6.3
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 72
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.780
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539132
Reka code 1101883
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 251
Conductor material Copper
Nominal diameter of conductor mm 6.3
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 72
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.780
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039137
Reka code 1101883

25 BU H07V2-K

Electric number Size Packaging Voltage

25 BU H07V2-K

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 251
Conductor material Copper
Nominal diameter of conductor mm 6.3
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 72
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.780
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541876
Reka code 1101887
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 251
Conductor material Copper
Nominal diameter of conductor mm 6.3
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 72
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.780
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039175
Reka code 1101887
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 251
Conductor material Copper
Nominal diameter of conductor mm 6.3
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 72
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.780
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539170
Reka code 1101887

25 GNYE H07V2-K

Electric number Size Packaging Voltage

25 GNYE H07V2-K

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 251
Conductor material Copper
Nominal diameter of conductor mm 6.3
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 72
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.780
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542484
Reka code 1101888
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 251
Conductor material Copper
Nominal diameter of conductor mm 6.3
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 72
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.780
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539187
Reka code 1101888
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 251
Conductor material Copper
Nominal diameter of conductor mm 6.3
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 72
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.780
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039182
Reka code 1101888

35 BK H07V2-K

Electric number Size Packaging Voltage

35 BK H07V2-K

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 345
Conductor material Copper
Nominal diameter of conductor mm 7.9
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.554
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539231
Reka code 1101893
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 345
Conductor material Copper
Nominal diameter of conductor mm 7.9
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.554
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039236
Reka code 1101893

35 BU H07V2-K

Electric number Size Packaging Voltage

35 BU H07V2-K

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 345
Conductor material Copper
Nominal diameter of conductor mm 7.9
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.554
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539279
Reka code 1101897
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 345
Conductor material Copper
Nominal diameter of conductor mm 7.9
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.554
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039274
Reka code 1101897

35 GNYE H07V2-K

Electric number Size Packaging Voltage

35 GNYE H07V2-K

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 345
Conductor material Copper
Nominal diameter of conductor mm 7.9
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.554
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542583
Reka code 1101898
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 345
Conductor material Copper
Nominal diameter of conductor mm 7.9
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.554
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539286
Reka code 1101898
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 345
Conductor material Copper
Nominal diameter of conductor mm 7.9
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.554
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039281
Reka code 1101898

50 BK H07V2-K

Electric number Size Packaging Voltage

50 BK H07V2-K

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 486
Conductor material Copper
Nominal diameter of conductor mm 8.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 96
In final installation, cable mm 36
During handling and installation, cable cm 10
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.386
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542538
Reka code 1101903
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 486
Conductor material Copper
Nominal diameter of conductor mm 8.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 96
In final installation, cable mm 36
During handling and installation, cable cm 10
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.386
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039335
Reka code 1101903
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 486
Conductor material Copper
Nominal diameter of conductor mm 8.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 96
In final installation, cable mm 36
During handling and installation, cable cm 10
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.386
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539330
Reka code 1101903

50 BU H07V2-K

Electric number Size Packaging Voltage

50 BU H07V2-K

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 486
Conductor material Copper
Nominal diameter of conductor mm 8.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 96
In final installation, cable mm 36
During handling and installation, cable cm 10
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.386
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539378
Reka code 1101907
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 486
Conductor material Copper
Nominal diameter of conductor mm 8.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 96
In final installation, cable mm 36
During handling and installation, cable cm 10
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.386
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541975
Reka code 1101907
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 486
Conductor material Copper
Nominal diameter of conductor mm 8.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 96
In final installation, cable mm 36
During handling and installation, cable cm 10
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.386
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039373
Reka code 1101907

50 GNYE H07V2-K

Electric number Size Packaging Voltage

50 GNYE H07V2-K

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 486
Conductor material Copper
Nominal diameter of conductor mm 8.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 96
In final installation, cable mm 36
During handling and installation, cable cm 10
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.386
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542682
Reka code 1101908
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 486
Conductor material Copper
Nominal diameter of conductor mm 8.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 96
In final installation, cable mm 36
During handling and installation, cable cm 10
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.386
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539385
Reka code 1101908
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 486
Conductor material Copper
Nominal diameter of conductor mm 8.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 96
In final installation, cable mm 36
During handling and installation, cable cm 10
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.386
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039380
Reka code 1101908

70 BK H07V2-K

Electric number Size Packaging Voltage

70 BK H07V2-K

Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 660
Conductor material Copper
Nominal diameter of conductor mm 10.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 112
In final installation, cable mm 42
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.272
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542736
Reka code 1101913
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 660
Conductor material Copper
Nominal diameter of conductor mm 10.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 112
In final installation, cable mm 42
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.272
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542637
Reka code 1101913
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 660
Conductor material Copper
Nominal diameter of conductor mm 10.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 112
In final installation, cable mm 42
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.272
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539439
Reka code 1101913
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 660
Conductor material Copper
Nominal diameter of conductor mm 10.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 112
In final installation, cable mm 42
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.272
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039434
Reka code 1101913

70 BU H07V2-K

Electric number Size Packaging Voltage

70 BU H07V2-K

Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 660
Conductor material Copper
Nominal diameter of conductor mm 10.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 112
In final installation, cable mm 42
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.272
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539477
Reka code 1101917
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 660
Conductor material Copper
Nominal diameter of conductor mm 10.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 112
In final installation, cable mm 42
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.272
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542071
Reka code 1101917
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 660
Conductor material Copper
Nominal diameter of conductor mm 10.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 112
In final installation, cable mm 42
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.272
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039472
Reka code 1101917

70 GNYE H07V2-K

Electric number Size Packaging Voltage

70 GNYE H07V2-K

Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 660
Conductor material Copper
Nominal diameter of conductor mm 10.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 112
In final installation, cable mm 42
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.272
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542781
Reka code 1101918
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 660
Conductor material Copper
Nominal diameter of conductor mm 10.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 112
In final installation, cable mm 42
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.272
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039489
Reka code 1101918
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 660
Conductor material Copper
Nominal diameter of conductor mm 10.7
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 112
In final installation, cable mm 42
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.272
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004539484
Reka code 1101918

95 BK H07V2-K

Electric number Size Packaging Voltage

95 BK H07V2-K

Nominal diameter of complete cable mm 16
Nominal weight of cable kg/km 931
Conductor material Copper
Nominal diameter of conductor mm 13
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 128
In final installation, cable mm 48
During handling and installation, cable cm 13
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 4.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.206
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542934
Reka code 1101923
Nominal diameter of complete cable mm 16
Nominal weight of cable kg/km 931
Conductor material Copper
Nominal diameter of conductor mm 13
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 128
In final installation, cable mm 48
During handling and installation, cable cm 13
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 4.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.206
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542835
Reka code 1101923
Nominal diameter of complete cable mm 16
Nominal weight of cable kg/km 931
Conductor material Copper
Nominal diameter of conductor mm 13
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 128
In final installation, cable mm 48
During handling and installation, cable cm 13
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 4.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.206
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039533
Reka code 1101923

95 BU H07V2-K

Electric number Size Packaging Voltage

95 BU H07V2-K

Nominal diameter of complete cable mm 16
Nominal weight of cable kg/km 931
Conductor material Copper
Nominal diameter of conductor mm 13
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 128
In final installation, cable mm 48
During handling and installation, cable cm 13
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 4.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.206
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542279
Reka code 1101927
Nominal diameter of complete cable mm 16
Nominal weight of cable kg/km 931
Conductor material Copper
Nominal diameter of conductor mm 13
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 128
In final installation, cable mm 48
During handling and installation, cable cm 13
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 4.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.206
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542170
Reka code 1101927

95 GNYE H07V2-K

Electric number Size Packaging Voltage

95 GNYE H07V2-K

Nominal diameter of complete cable mm 16
Nominal weight of cable kg/km 931
Conductor material Copper
Nominal diameter of conductor mm 13
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 128
In final installation, cable mm 48
During handling and installation, cable cm 13
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 4.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.206
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542989
Reka code 1101928
Nominal diameter of complete cable mm 16
Nominal weight of cable kg/km 931
Conductor material Copper
Nominal diameter of conductor mm 13
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 128
In final installation, cable mm 48
During handling and installation, cable cm 13
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 4.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.206
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004542880
Reka code 1101928

120 BK H07V2-K

Electric number Size Packaging Voltage

120 BK H07V2-K

Nominal diameter of complete cable mm 18
Nominal weight of cable kg/km 1157
Conductor material Copper
Nominal diameter of conductor mm 15.2
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 144
In final installation, cable mm 54
During handling and installation, cable cm 14
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 6
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.161
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004543139
Reka code 1101933
Nominal diameter of complete cable mm 18
Nominal weight of cable kg/km 1157
Conductor material Copper
Nominal diameter of conductor mm 15.2
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 144
In final installation, cable mm 54
During handling and installation, cable cm 14
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 6
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.161
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004543030
Reka code 1101933
Nominal diameter of complete cable mm 18
Nominal weight of cable kg/km 1157
Conductor material Copper
Nominal diameter of conductor mm 15.2
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 144
In final installation, cable mm 54
During handling and installation, cable cm 14
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 6
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.161
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004039632
Reka code 1101933

120 GNYE H07V2-K

Electric number Size Packaging Voltage

120 GNYE H07V2-K

Nominal diameter of complete cable mm 18
Nominal weight of cable kg/km 1157
Conductor material Copper
Nominal diameter of conductor mm 15.2
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 144
In final installation, cable mm 54
During handling and installation, cable cm 14
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 6
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0.161
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004543085
Reka code 1101938