MKEM 90 (H07V2-K)

Conductor may be laid indoors. For fixed installation in conduits, for fixed internal wiring in electrical equipments.

Standards EN 50525-2-31:2011
Reaction to fire Eca
CPR - DoP 2017042_DOP.pdf
Conductor Circular flexible copper, EN/IEC 60228 class 5
Insulation PVC-compound
Core Identification (all color combinations in the cable family) Yellow-green
blue
brown
black
gray
Red

1,5 GY H07V2-K

Electric number Size Packing (m) Voltage

1,5 GY H07V2-K

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.5
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 13.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038000
Reka code 1101820

1,5 BN H07V2-K

Electric number Size Packing (m) Voltage

1,5 BN H07V2-K

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.5
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 13.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038024
Reka code 1101822

1,5 BK H07V2-K

Electric number Size Packing (m) Voltage

1,5 BK H07V2-K

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.5
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 13.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004541630
Reka code 1101823
Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.5
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 13.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004541531
Reka code 1101823
Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.5
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 13.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038031
Reka code 1101823

1,5 BU H07V2-K

Electric number Size Packing (m) Voltage

1,5 BU H07V2-K

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.5
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 13.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004541371
Reka code 1101827
Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.5
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 13.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004541272
Reka code 1101827
Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.5
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 13.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038079
Reka code 1101827

1,5 GNYE H07V2-K

Electric number Size Packing (m) Voltage

1,5 GNYE H07V2-K

Nominal diameter of complete cable (mm) 3
Nominal weight of cable (kg/km) 19
Conductor material Copper
Nominal diameter of conductor (mm) 1.5
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 24
In final installation, cable (cm) 9
During handling and installation, cable (cm) 3
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.08
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 13.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.17
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038086
Reka code 1101828

2,5 BK H07V2-K

Electric number Size Packing (m) Voltage

2,5 BK H07V2-K

Nominal diameter of complete cable (mm) 4
Nominal weight of cable (kg/km) 28
Conductor material Copper
Nominal diameter of conductor (mm) 2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 32
In final installation, cable (cm) 12
During handling and installation, cable (cm) 4
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.13
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.98
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004541838
Reka code 1101833
Nominal diameter of complete cable (mm) 4
Nominal weight of cable (kg/km) 28
Conductor material Copper
Nominal diameter of conductor (mm) 2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 32
In final installation, cable (cm) 12
During handling and installation, cable (cm) 4
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.13
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.98
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038239
Reka code 1101833

2,5 BU H07V2-K

Electric number Size Packing (m) Voltage

2,5 BU H07V2-K

Nominal diameter of complete cable (mm) 4
Nominal weight of cable (kg/km) 28
Conductor material Copper
Nominal diameter of conductor (mm) 2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 32
In final installation, cable (cm) 12
During handling and installation, cable (cm) 4
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.13
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.98
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038277
Reka code 1101837
Nominal diameter of complete cable (mm) 4
Nominal weight of cable (kg/km) 28
Conductor material Copper
Nominal diameter of conductor (mm) 2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 32
In final installation, cable (cm) 12
During handling and installation, cable (cm) 4
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.13
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.98
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004541470
Reka code 1101837

2,5 GNYE H07V2-K

Electric number Size Packing (m) Voltage

2,5 GNYE H07V2-K

Nominal diameter of complete cable (mm) 4
Nominal weight of cable (kg/km) 28
Conductor material Copper
Nominal diameter of conductor (mm) 2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 32
In final installation, cable (cm) 12
During handling and installation, cable (cm) 4
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.13
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 7.98
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.29
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038284
Reka code 1101838

4 BN H07V2-K

Electric number Size Packing (m) Voltage

4 BN H07V2-K

Nominal diameter of complete cable (mm) 4
Nominal weight of cable (kg/km) 44
Conductor material Copper
Nominal diameter of conductor (mm) 2.4
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 32
In final installation, cable (cm) 12
During handling and installation, cable (cm) 4
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.2
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 4.95
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.46
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038420
Reka code 1101842

4 BK H07V2-K

Electric number Size Packing (m) Voltage

4 BK H07V2-K

Nominal diameter of complete cable (mm) 4
Nominal weight of cable (kg/km) 44
Conductor material Copper
Nominal diameter of conductor (mm) 2.4
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 32
In final installation, cable (cm) 12
During handling and installation, cable (cm) 4
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.2
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 4.95
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.46
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542033
Reka code 1101843
Nominal diameter of complete cable (mm) 4
Nominal weight of cable (kg/km) 44
Conductor material Copper
Nominal diameter of conductor (mm) 2.4
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 32
In final installation, cable (cm) 12
During handling and installation, cable (cm) 4
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.2
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 4.95
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.46
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038437
Reka code 1101843

4 BU H07V2-K

Electric number Size Packing (m) Voltage

4 BU H07V2-K

Nominal diameter of complete cable (mm) 4
Nominal weight of cable (kg/km) 44
Conductor material Copper
Nominal diameter of conductor (mm) 2.4
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 32
In final installation, cable (cm) 12
During handling and installation, cable (cm) 4
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.2
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 4.95
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.46
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038475
Reka code 1101847

4 GNYE H07V2-K

Electric number Size Packing (m) Voltage

4 GNYE H07V2-K

Nominal diameter of complete cable (mm) 4
Nominal weight of cable (kg/km) 44
Conductor material Copper
Nominal diameter of conductor (mm) 2.4
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 32
In final installation, cable (cm) 12
During handling and installation, cable (cm) 4
In final installation, cable (cm) 1
Pulling force
Pulling-eye (kN) 0.2
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 4.95
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.46
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038482
Reka code 1101848

6 BN H07V2-K

Electric number Size Packing (m) Voltage

6 BN H07V2-K

Nominal diameter of complete cable (mm) 5
Nominal weight of cable (kg/km) 59
Conductor material Copper
Nominal diameter of conductor (mm) 3.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 40
In final installation, cable (cm) 15
During handling and installation, cable (cm) 5
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004540121
Reka code 1101852
Nominal diameter of complete cable (mm) 5
Nominal weight of cable (kg/km) 59
Conductor material Copper
Nominal diameter of conductor (mm) 3.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 40
In final installation, cable (cm) 15
During handling and installation, cable (cm) 5
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038628
Reka code 1101852

6 BK H07V2-K

Electric number Size Packing (m) Voltage

6 BK H07V2-K

Nominal diameter of complete cable (mm) 5
Nominal weight of cable (kg/km) 59
Conductor material Copper
Nominal diameter of conductor (mm) 3.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 40
In final installation, cable (cm) 15
During handling and installation, cable (cm) 5
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542231
Reka code 1101853
Nominal diameter of complete cable (mm) 5
Nominal weight of cable (kg/km) 59
Conductor material Copper
Nominal diameter of conductor (mm) 3.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 40
In final installation, cable (cm) 15
During handling and installation, cable (cm) 5
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038635
Reka code 1101853
Nominal diameter of complete cable (mm) 5
Nominal weight of cable (kg/km) 59
Conductor material Copper
Nominal diameter of conductor (mm) 3.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 40
In final installation, cable (cm) 15
During handling and installation, cable (cm) 5
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542132
Reka code 1101853

6 BU H07V2-K

Electric number Size Packing (m) Voltage

6 BU H07V2-K

Nominal diameter of complete cable (mm) 5
Nominal weight of cable (kg/km) 59
Conductor material Copper
Nominal diameter of conductor (mm) 3.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 40
In final installation, cable (cm) 15
During handling and installation, cable (cm) 5
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004541678
Reka code 1101857
Nominal diameter of complete cable (mm) 5
Nominal weight of cable (kg/km) 59
Conductor material Copper
Nominal diameter of conductor (mm) 3.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 40
In final installation, cable (cm) 15
During handling and installation, cable (cm) 5
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004541579
Reka code 1101857
Nominal diameter of complete cable (mm) 5
Nominal weight of cable (kg/km) 59
Conductor material Copper
Nominal diameter of conductor (mm) 3.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 40
In final installation, cable (cm) 15
During handling and installation, cable (cm) 5
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038673
Reka code 1101857

6 GNYE H07V2-K

Electric number Size Packing (m) Voltage

6 GNYE H07V2-K

Nominal diameter of complete cable (mm) 5
Nominal weight of cable (kg/km) 59
Conductor material Copper
Nominal diameter of conductor (mm) 3.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 40
In final installation, cable (cm) 15
During handling and installation, cable (cm) 5
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038680
Reka code 1101858
Nominal diameter of complete cable (mm) 5
Nominal weight of cable (kg/km) 59
Conductor material Copper
Nominal diameter of conductor (mm) 3.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 40
In final installation, cable (cm) 15
During handling and installation, cable (cm) 5
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542286
Reka code 1101858
Nominal diameter of complete cable (mm) 5
Nominal weight of cable (kg/km) 59
Conductor material Copper
Nominal diameter of conductor (mm) 3.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 40
In final installation, cable (cm) 15
During handling and installation, cable (cm) 5
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.3
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 3.3
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 0.69
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542187
Reka code 1101858

10 GY H07V2-K

Electric number Size Packing (m) Voltage

10 GY H07V2-K

Nominal diameter of complete cable (mm) 6
Nominal weight of cable (kg/km) 111
Conductor material Copper
Nominal diameter of conductor (mm) 4.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 48
In final installation, cable (cm) 18
During handling and installation, cable (cm) 6
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.91
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.15
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038802
Reka code 1101860

10 BN H07V2-K

Electric number Size Packing (m) Voltage

10 BN H07V2-K

Nominal diameter of complete cable (mm) 6
Nominal weight of cable (kg/km) 111
Conductor material Copper
Nominal diameter of conductor (mm) 4.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 48
In final installation, cable (cm) 18
During handling and installation, cable (cm) 6
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.91
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.15
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038826
Reka code 1101862

10 BK H07V2-K

Electric number Size Packing (m) Voltage

10 BK H07V2-K

Nominal diameter of complete cable (mm) 6
Nominal weight of cable (kg/km) 111
Conductor material Copper
Nominal diameter of conductor (mm) 4.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 48
In final installation, cable (cm) 18
During handling and installation, cable (cm) 6
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.91
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.15
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004538838
Reka code 1101863
Nominal diameter of complete cable (mm) 6
Nominal weight of cable (kg/km) 111
Conductor material Copper
Nominal diameter of conductor (mm) 4.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 48
In final installation, cable (cm) 18
During handling and installation, cable (cm) 6
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.91
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.15
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038833
Reka code 1101863

10 BU H07V2-K

Electric number Size Packing (m) Voltage

10 BU H07V2-K

Nominal diameter of complete cable (mm) 6
Nominal weight of cable (kg/km) 111
Conductor material Copper
Nominal diameter of conductor (mm) 4.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 48
In final installation, cable (cm) 18
During handling and installation, cable (cm) 6
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.91
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.15
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038871
Reka code 1101867
Nominal diameter of complete cable (mm) 6
Nominal weight of cable (kg/km) 111
Conductor material Copper
Nominal diameter of conductor (mm) 4.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 48
In final installation, cable (cm) 18
During handling and installation, cable (cm) 6
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.91
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.15
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004538876
Reka code 1101867

10 GNYE H07V2-K

Electric number Size Packing (m) Voltage

10 GNYE H07V2-K

Nominal diameter of complete cable (mm) 6
Nominal weight of cable (kg/km) 111
Conductor material Copper
Nominal diameter of conductor (mm) 4.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 48
In final installation, cable (cm) 18
During handling and installation, cable (cm) 6
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.91
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.15
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004538883
Reka code 1101868
Nominal diameter of complete cable (mm) 6
Nominal weight of cable (kg/km) 111
Conductor material Copper
Nominal diameter of conductor (mm) 4.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 48
In final installation, cable (cm) 18
During handling and installation, cable (cm) 6
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.91
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.15
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004038888
Reka code 1101868

16 BK H07V2-K

Electric number Size Packing (m) Voltage

16 BK H07V2-K

Nominal diameter of complete cable (mm) 7
Nominal weight of cable (kg/km) 164
Conductor material Copper
Nominal diameter of conductor (mm) 5.1
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 56
In final installation, cable (cm) 21
During handling and installation, cable (cm) 7
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.8
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.21
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.84
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039038
Reka code 1101873
Nominal diameter of complete cable (mm) 7
Nominal weight of cable (kg/km) 164
Conductor material Copper
Nominal diameter of conductor (mm) 5.1
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 56
In final installation, cable (cm) 21
During handling and installation, cable (cm) 7
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.8
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.21
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.84
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539033
Reka code 1101873
Nominal diameter of complete cable (mm) 7
Nominal weight of cable (kg/km) 164
Conductor material Copper
Nominal diameter of conductor (mm) 5.1
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 56
In final installation, cable (cm) 21
During handling and installation, cable (cm) 7
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.8
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.21
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.84
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542330
Reka code 1101873

16 BU H07V2-K

Electric number Size Packing (m) Voltage

16 BU H07V2-K

Nominal diameter of complete cable (mm) 7
Nominal weight of cable (kg/km) 164
Conductor material Copper
Nominal diameter of conductor (mm) 5.1
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 56
In final installation, cable (cm) 21
During handling and installation, cable (cm) 7
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.8
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.21
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.84
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004541777
Reka code 1101877
Nominal diameter of complete cable (mm) 7
Nominal weight of cable (kg/km) 164
Conductor material Copper
Nominal diameter of conductor (mm) 5.1
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 56
In final installation, cable (cm) 21
During handling and installation, cable (cm) 7
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.8
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.21
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.84
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539071
Reka code 1101877
Nominal diameter of complete cable (mm) 7
Nominal weight of cable (kg/km) 164
Conductor material Copper
Nominal diameter of conductor (mm) 5.1
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 56
In final installation, cable (cm) 21
During handling and installation, cable (cm) 7
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.8
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.21
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.84
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039076
Reka code 1101877

16 GNYE H07V2-K

Electric number Size Packing (m) Voltage

16 GNYE H07V2-K

Nominal diameter of complete cable (mm) 7
Nominal weight of cable (kg/km) 164
Conductor material Copper
Nominal diameter of conductor (mm) 5.1
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 56
In final installation, cable (cm) 21
During handling and installation, cable (cm) 7
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.8
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.21
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.84
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542385
Reka code 1101878
Nominal diameter of complete cable (mm) 7
Nominal weight of cable (kg/km) 164
Conductor material Copper
Nominal diameter of conductor (mm) 5.1
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 56
In final installation, cable (cm) 21
During handling and installation, cable (cm) 7
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.8
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.21
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.84
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539088
Reka code 1101878
Nominal diameter of complete cable (mm) 7
Nominal weight of cable (kg/km) 164
Conductor material Copper
Nominal diameter of conductor (mm) 5.1
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 56
In final installation, cable (cm) 21
During handling and installation, cable (cm) 7
In final installation, cable (cm) 2
Pulling force
Pulling-eye (kN) 0.8
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 1.21
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 1.84
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039083
Reka code 1101878

25 BK H07V2-K

Electric number Size Packing (m) Voltage

25 BK H07V2-K

Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 251
Conductor material Copper
Nominal diameter of conductor (mm) 6.3
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 72
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.78
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 2.88
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542439
Reka code 1101883
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 251
Conductor material Copper
Nominal diameter of conductor (mm) 6.3
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 72
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.78
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 2.88
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539132
Reka code 1101883
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 251
Conductor material Copper
Nominal diameter of conductor (mm) 6.3
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 72
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.78
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 2.88
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039137
Reka code 1101883

25 BU H07V2-K

Electric number Size Packing (m) Voltage

25 BU H07V2-K

Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 251
Conductor material Copper
Nominal diameter of conductor (mm) 6.3
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 72
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.78
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 2.88
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004541876
Reka code 1101887
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 251
Conductor material Copper
Nominal diameter of conductor (mm) 6.3
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 72
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.78
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 2.88
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039175
Reka code 1101887
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 251
Conductor material Copper
Nominal diameter of conductor (mm) 6.3
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 72
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.78
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 2.88
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539170
Reka code 1101887

25 GNYE H07V2-K

Electric number Size Packing (m) Voltage

25 GNYE H07V2-K

Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 251
Conductor material Copper
Nominal diameter of conductor (mm) 6.3
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 72
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.78
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 2.88
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542484
Reka code 1101888
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 251
Conductor material Copper
Nominal diameter of conductor (mm) 6.3
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 72
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.78
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 2.88
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539187
Reka code 1101888
Nominal diameter of complete cable (mm) 9
Nominal weight of cable (kg/km) 251
Conductor material Copper
Nominal diameter of conductor (mm) 6.3
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 72
In final installation, cable (cm) 27
During handling and installation, cable (cm) 9
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.25
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.78
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 2.88
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039182
Reka code 1101888

35 BK H07V2-K

Electric number Size Packing (m) Voltage

35 BK H07V2-K

Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 345
Conductor material Copper
Nominal diameter of conductor (mm) 7.9
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 80
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.554
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 4.03
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539231
Reka code 1101893
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 345
Conductor material Copper
Nominal diameter of conductor (mm) 7.9
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 80
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.554
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 4.03
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039236
Reka code 1101893

35 BU H07V2-K

Electric number Size Packing (m) Voltage

35 BU H07V2-K

Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 345
Conductor material Copper
Nominal diameter of conductor (mm) 7.9
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 80
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.554
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 4.03
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539279
Reka code 1101897
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 345
Conductor material Copper
Nominal diameter of conductor (mm) 7.9
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 80
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.554
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 4.03
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039274
Reka code 1101897

35 GNYE H07V2-K

Electric number Size Packing (m) Voltage

35 GNYE H07V2-K

Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 345
Conductor material Copper
Nominal diameter of conductor (mm) 7.9
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 80
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.554
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 4.03
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542583
Reka code 1101898
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 345
Conductor material Copper
Nominal diameter of conductor (mm) 7.9
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 80
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.554
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 4.03
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539286
Reka code 1101898
Nominal diameter of complete cable (mm) 10
Nominal weight of cable (kg/km) 345
Conductor material Copper
Nominal diameter of conductor (mm) 7.9
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 80
In final installation, cable (cm) 30
During handling and installation, cable (cm) 10
In final installation, cable (cm) 3
Pulling force
Pulling-eye (kN) 1.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.554
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 4.03
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039281
Reka code 1101898

50 BK H07V2-K

Electric number Size Packing (m) Voltage

50 BK H07V2-K

Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 486
Conductor material Copper
Nominal diameter of conductor (mm) 8.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 96
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 2.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.386
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 5.75
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542538
Reka code 1101903
Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 486
Conductor material Copper
Nominal diameter of conductor (mm) 8.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 96
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 2.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.386
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 5.75
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039335
Reka code 1101903
Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 486
Conductor material Copper
Nominal diameter of conductor (mm) 8.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 96
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 2.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.386
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 5.75
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539330
Reka code 1101903

50 BU H07V2-K

Electric number Size Packing (m) Voltage

50 BU H07V2-K

Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 486
Conductor material Copper
Nominal diameter of conductor (mm) 8.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 96
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 2.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.386
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 5.75
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539378
Reka code 1101907
Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 486
Conductor material Copper
Nominal diameter of conductor (mm) 8.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 96
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 2.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.386
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 5.75
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004541975
Reka code 1101907
Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 486
Conductor material Copper
Nominal diameter of conductor (mm) 8.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 96
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 2.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.386
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 5.75
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039373
Reka code 1101907

50 GNYE H07V2-K

Electric number Size Packing (m) Voltage

50 GNYE H07V2-K

Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 486
Conductor material Copper
Nominal diameter of conductor (mm) 8.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 96
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 2.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.386
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 5.75
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542682
Reka code 1101908
Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 486
Conductor material Copper
Nominal diameter of conductor (mm) 8.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 96
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 2.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.386
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 5.75
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539385
Reka code 1101908
Nominal diameter of complete cable (mm) 12
Nominal weight of cable (kg/km) 486
Conductor material Copper
Nominal diameter of conductor (mm) 8.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 96
In final installation, cable (cm) 36
During handling and installation, cable (cm) 12
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 2.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.386
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 5.75
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039380
Reka code 1101908

70 BK H07V2-K

Electric number Size Packing (m) Voltage

70 BK H07V2-K

Nominal diameter of complete cable (mm) 14
Nominal weight of cable (kg/km) 660
Conductor material Copper
Nominal diameter of conductor (mm) 10.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 112
In final installation, cable (cm) 42
During handling and installation, cable (cm) 14
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 3.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.272
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 8.05
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542736
Reka code 1101913
Nominal diameter of complete cable (mm) 14
Nominal weight of cable (kg/km) 660
Conductor material Copper
Nominal diameter of conductor (mm) 10.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 112
In final installation, cable (cm) 42
During handling and installation, cable (cm) 14
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 3.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.272
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 8.05
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542637
Reka code 1101913
Nominal diameter of complete cable (mm) 14
Nominal weight of cable (kg/km) 660
Conductor material Copper
Nominal diameter of conductor (mm) 10.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 112
In final installation, cable (cm) 42
During handling and installation, cable (cm) 14
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 3.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.272
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 8.05
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539439
Reka code 1101913
Nominal diameter of complete cable (mm) 14
Nominal weight of cable (kg/km) 660
Conductor material Copper
Nominal diameter of conductor (mm) 10.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 112
In final installation, cable (cm) 42
During handling and installation, cable (cm) 14
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 3.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.272
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 8.05
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039434
Reka code 1101913

70 BU H07V2-K

Electric number Size Packing (m) Voltage

70 BU H07V2-K

Nominal diameter of complete cable (mm) 14
Nominal weight of cable (kg/km) 660
Conductor material Copper
Nominal diameter of conductor (mm) 10.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 112
In final installation, cable (cm) 42
During handling and installation, cable (cm) 14
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 3.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.272
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 8.05
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539477
Reka code 1101917
Nominal diameter of complete cable (mm) 14
Nominal weight of cable (kg/km) 660
Conductor material Copper
Nominal diameter of conductor (mm) 10.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 112
In final installation, cable (cm) 42
During handling and installation, cable (cm) 14
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 3.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.272
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 8.05
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542071
Reka code 1101917
Nominal diameter of complete cable (mm) 14
Nominal weight of cable (kg/km) 660
Conductor material Copper
Nominal diameter of conductor (mm) 10.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 112
In final installation, cable (cm) 42
During handling and installation, cable (cm) 14
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 3.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.272
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 8.05
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039472
Reka code 1101917

70 GNYE H07V2-K

Electric number Size Packing (m) Voltage

70 GNYE H07V2-K

Nominal diameter of complete cable (mm) 14
Nominal weight of cable (kg/km) 660
Conductor material Copper
Nominal diameter of conductor (mm) 10.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 112
In final installation, cable (cm) 42
During handling and installation, cable (cm) 14
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 3.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.272
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 8.05
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542781
Reka code 1101918
Nominal diameter of complete cable (mm) 14
Nominal weight of cable (kg/km) 660
Conductor material Copper
Nominal diameter of conductor (mm) 10.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 112
In final installation, cable (cm) 42
During handling and installation, cable (cm) 14
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 3.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.272
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 8.05
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039489
Reka code 1101918
Nominal diameter of complete cable (mm) 14
Nominal weight of cable (kg/km) 660
Conductor material Copper
Nominal diameter of conductor (mm) 10.7
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 112
In final installation, cable (cm) 42
During handling and installation, cable (cm) 14
In final installation, cable (cm) 4
Pulling force
Pulling-eye (kN) 3.5
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.272
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 8.05
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004539484
Reka code 1101918

95 BK H07V2-K

Electric number Size Packing (m) Voltage

95 BK H07V2-K

Nominal diameter of complete cable (mm) 16
Nominal weight of cable (kg/km) 931
Conductor material Copper
Nominal diameter of conductor (mm) 13
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 128
In final installation, cable (cm) 48
During handling and installation, cable (cm) 16
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 4.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.206
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 10.93
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542934
Reka code 1101923
Nominal diameter of complete cable (mm) 16
Nominal weight of cable (kg/km) 931
Conductor material Copper
Nominal diameter of conductor (mm) 13
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 128
In final installation, cable (cm) 48
During handling and installation, cable (cm) 16
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 4.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.206
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 10.93
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542835
Reka code 1101923
Nominal diameter of complete cable (mm) 16
Nominal weight of cable (kg/km) 931
Conductor material Copper
Nominal diameter of conductor (mm) 13
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 128
In final installation, cable (cm) 48
During handling and installation, cable (cm) 16
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 4.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.206
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 10.93
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039533
Reka code 1101923

120 BK H07V2-K

Electric number Size Packing (m) Voltage

120 BK H07V2-K

Nominal diameter of complete cable (mm) 18
Nominal weight of cable (kg/km) 1157
Conductor material Copper
Nominal diameter of conductor (mm) 15.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 144
In final installation, cable (cm) 54
During handling and installation, cable (cm) 18
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 6
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.161
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 13.8
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004543139
Reka code 1101933
Nominal diameter of complete cable (mm) 18
Nominal weight of cable (kg/km) 1157
Conductor material Copper
Nominal diameter of conductor (mm) 15.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 144
In final installation, cable (cm) 54
During handling and installation, cable (cm) 18
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 6
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.161
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 13.8
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004543030
Reka code 1101933
Nominal diameter of complete cable (mm) 18
Nominal weight of cable (kg/km) 1157
Conductor material Copper
Nominal diameter of conductor (mm) 15.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 144
In final installation, cable (cm) 54
During handling and installation, cable (cm) 18
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 6
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.161
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 13.8
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004039632
Reka code 1101933

95 BU H07V2-K

Electric number Size Packing (m) Voltage

95 BU H07V2-K

Nominal diameter of complete cable (mm) 16
Nominal weight of cable (kg/km) 931
Conductor material Copper
Nominal diameter of conductor (mm) 13
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 128
In final installation, cable (cm) 48
During handling and installation, cable (cm) 16
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 4.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.206
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 10.93
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542279
Reka code 1101927
Nominal diameter of complete cable (mm) 16
Nominal weight of cable (kg/km) 931
Conductor material Copper
Nominal diameter of conductor (mm) 13
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 128
In final installation, cable (cm) 48
During handling and installation, cable (cm) 16
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 4.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.206
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 10.93
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542170
Reka code 1101927

95 GNYE H07V2-K

Electric number Size Packing (m) Voltage

95 GNYE H07V2-K

Nominal diameter of complete cable (mm) 16
Nominal weight of cable (kg/km) 931
Conductor material Copper
Nominal diameter of conductor (mm) 13
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 128
In final installation, cable (cm) 48
During handling and installation, cable (cm) 16
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 4.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.206
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 10.93
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542989
Reka code 1101928
Nominal diameter of complete cable (mm) 16
Nominal weight of cable (kg/km) 931
Conductor material Copper
Nominal diameter of conductor (mm) 13
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 128
In final installation, cable (cm) 48
During handling and installation, cable (cm) 16
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 4.75
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.206
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 10.93
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004542880
Reka code 1101928

120 GNYE H07V2-K

Electric number Size Packing (m) Voltage

120 GNYE H07V2-K

Nominal diameter of complete cable (mm) 18
Nominal weight of cable (kg/km) 1157
Conductor material Copper
Nominal diameter of conductor (mm) 15.2
Nominal cross-sectional area of conductor (mm2) 0
Bending radius
During handling and installation, cable (cm) 144
In final installation, cable (cm) 54
During handling and installation, cable (cm) 18
In final installation, cable (cm) 5
Pulling force
Pulling-eye (kN) 6
Pulling-stocking (kN) 0
Resistance 20 °C (ohm/km) 0.161
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -15
Minimum cable temperature during operation (°C) -40
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 13.8
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 160
EAN code 6410004543085
Reka code 1101938