MK 90 /H07V2-R

Download product group datasheet

Installation wirefor fixed installations indoors. For internal wiring of electrical devices. Maximum conductor temperature in normal operation 90 °C. The conductor insulation must be protected against UV-radiation. The cable is flame-retardant according to CPR-class Eca.

Standards EN 50525-2-31
Reaction to fire Eca
CPR - DoP 2017041_DOP.pdf
Conductor Circular stranded copper, EN/IEC 60228 class 2
Insulation PVC-compound
Core Identification (all color combinations in the cable family) Yellowgreen
Blue
Brown
Black
Grey
Orange
Red

1,5 GY H07V2-R

Electric number Size Packaging Voltage

1,5 GY H07V2-R

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 21
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028001
Reka code 1101480

1,5 BN H07V2-R

Electric number Size Packaging Voltage

1,5 BN H07V2-R

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 21
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028025
Reka code 1101482

1,5 BK H07V2-R

Electric number Size Packaging Voltage

1,5 BK H07V2-R

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 21
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028032
Reka code 1101483

1,5 BU H07V2-R

Electric number Size Packaging Voltage

1,5 BU H07V2-R

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 21
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028070
Reka code 1101487

1,5 GNYE H07V2-R

Electric number Size Packaging Voltage

1,5 GNYE H07V2-R

Nominal diameter of complete cable mm 3
Nominal weight of cable kg/km 21
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 1
Min. bending radius
During handling and installation, cable mm 24
In final installation, cable mm 9
During handling and installation, cable cm 2
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028087
Reka code 1101488

2,5 GY H07V2-R

Electric number Size Packaging Voltage

2,5 GY H07V2-R

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 33
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 29
In final installation, cable mm 11
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028209
Reka code 1101490

2,5 BN H07V2-R

Electric number Size Packaging Voltage

2,5 BN H07V2-R

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 33
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 29
In final installation, cable mm 11
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028223
Reka code 1101492

2,5 BK H07V2-R

Electric number Size Packaging Voltage

2,5 BK H07V2-R

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 33
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 29
In final installation, cable mm 11
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028230
Reka code 1101493

2,5 BU H07V2-R

Electric number Size Packaging Voltage

2,5 BU H07V2-R

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 33
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 29
In final installation, cable mm 11
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028278
Reka code 1101497

2,5 GNYE H07V2-R

Electric number Size Packaging Voltage

2,5 GNYE H07V2-R

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 33
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 29
In final installation, cable mm 11
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.13
Pulling-stocking kN 0
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028285
Reka code 1101498

4 BK H07V2-R

Electric number Size Packaging Voltage

4 BK H07V2-R

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 50
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 33
In final installation, cable mm 13
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0
Resistance 20 °C Ω/km 4,61
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028438
Reka code 1101503

4 BU H07V2-R

Electric number Size Packaging Voltage

4 BU H07V2-R

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 50
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 33
In final installation, cable mm 13
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0
Resistance 20 °C Ω/km 4,61
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028476
Reka code 1101507

4 GNYE H07V2-R

Electric number Size Packaging Voltage

4 GNYE H07V2-R

Nominal diameter of complete cable mm 4
Nominal weight of cable kg/km 50
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 33
In final installation, cable mm 13
During handling and installation, cable cm 3
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0
Resistance 20 °C Ω/km 4,61
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028483
Reka code 1101508

6 BN H07V2-R

Electric number Size Packaging Voltage

6 BN H07V2-R

Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 67
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 38
In final installation, cable mm 14
During handling and installation, cable cm 4
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3,08
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004528624
Reka code 1101512
Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 67
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 38
In final installation, cable mm 14
During handling and installation, cable cm 4
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3,08
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028629
Reka code 1101512

6 BK H07V2-R

Electric number Size Packaging Voltage

6 BK H07V2-R

Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 69
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 38
In final installation, cable mm 14
During handling and installation, cable cm 4
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3,08
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004528631
Reka code 1101513
Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 69
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 38
In final installation, cable mm 14
During handling and installation, cable cm 4
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3,08
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028636
Reka code 1101513

6 BU H07V2-R

Electric number Size Packaging Voltage

6 BU H07V2-R

Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 69
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 38
In final installation, cable mm 14
During handling and installation, cable cm 4
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3,08
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004528679
Reka code 1101517
Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 69
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 38
In final installation, cable mm 14
During handling and installation, cable cm 4
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3,08
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028674
Reka code 1101517

6 GNYE H07V2-R

Electric number Size Packaging Voltage

6 GNYE H07V2-R

Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 69
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 38
In final installation, cable mm 14
During handling and installation, cable cm 4
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3,08
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004540985
Reka code 1101518
Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 69
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 38
In final installation, cable mm 14
During handling and installation, cable cm 4
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3,08
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004528686
Reka code 1101518
Nominal diameter of complete cable mm 5
Nominal weight of cable kg/km 69
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.8
Number of wires 1
Min. bending radius
During handling and installation, cable mm 38
In final installation, cable mm 14
During handling and installation, cable cm 4
In final installation, cable cm 1
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0
Resistance 20 °C Ω/km 3,08
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028681
Reka code 1101518

10 BK H07V2-R

Electric number Size Packaging Voltage

10 BK H07V2-R

Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,83
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028834
Reka code 1101523
Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,83
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004540534
Reka code 1101523
Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,83
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004528839
Reka code 1101523

10 BU H07V2-R

Electric number Size Packaging Voltage

10 BU H07V2-R

Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,83
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004528877
Reka code 1101527
Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,83
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004540473
Reka code 1101527
Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,83
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028872
Reka code 1101527

10 GNYE H07V2-R

Electric number Size Packaging Voltage

10 GNYE H07V2-R

Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,83
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004528884
Reka code 1101528
Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,83
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541081
Reka code 1101528
Nominal diameter of complete cable mm 6
Nominal weight of cable kg/km 111
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 48
In final installation, cable mm 18
During handling and installation, cable cm 5
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,83
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004028889
Reka code 1101528

16 BK H07V2-R

Electric number Size Packaging Voltage

16 BK H07V2-R

Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 177
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 58
In final installation, cable mm 22
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,15
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529034
Reka code 1101533
Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 177
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 58
In final installation, cable mm 22
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,15
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029039
Reka code 1101533

16 BU H07V2-R

Electric number Size Packaging Voltage

16 BU H07V2-R

Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 177
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 58
In final installation, cable mm 22
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,15
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529072
Reka code 1101537
Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 177
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 58
In final installation, cable mm 22
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,15
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029077
Reka code 1101537

16 GNYE H07V2-R

Electric number Size Packaging Voltage

16 GNYE H07V2-R

Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 177
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 58
In final installation, cable mm 22
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,15
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529089
Reka code 1101538
Nominal diameter of complete cable mm 7
Nominal weight of cable kg/km 177
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 1
Number of wires 1
Min. bending radius
During handling and installation, cable mm 58
In final installation, cable mm 22
During handling and installation, cable cm 6
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0
Resistance 20 °C Ω/km 1,15
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029084
Reka code 1101538

25 BK H07V2-R

Electric number Size Packaging Voltage

25 BK H07V2-R

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 272
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 71
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,727
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004540633
Reka code 1101543
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 272
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 71
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,727
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029138
Reka code 1101543
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 272
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 71
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,727
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529133
Reka code 1101543

25 BU H07V2-R

Electric number Size Packaging Voltage

25 BU H07V2-R

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 271
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 70
In final installation, cable mm 26
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,727
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529171
Reka code 1101547
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 271
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 70
In final installation, cable mm 26
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,727
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004540572
Reka code 1101547
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 271
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 70
In final installation, cable mm 26
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,727
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029176
Reka code 1101547

25 GNYE H07V2-R

Electric number Size Packaging Voltage

25 GNYE H07V2-R

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 272
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 71
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,727
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029183
Reka code 1101548
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 272
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 71
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,727
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541685
Reka code 1101548
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 272
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 71
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,727
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529188
Reka code 1101548
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 272
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 71
In final installation, cable mm 27
During handling and installation, cable cm 7
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.25
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,727
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541586
Reka code 1101548

35 BK H07V2-R

Electric number Size Packaging Voltage

35 BK H07V2-R

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 364
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,524
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529232
Reka code 1101553
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 364
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,524
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004540732
Reka code 1101553
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 364
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,524
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029237
Reka code 1101553

35 BU H07V2-R

Electric number Size Packaging Voltage

35 BU H07V2-R

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 364
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,524
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529270
Reka code 1101557
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 364
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,524
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004540671
Reka code 1101557
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 364
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,524
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029275
Reka code 1101557

35 GNYE H07V2-R

Electric number Size Packaging Voltage

35 GNYE H07V2-R

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 364
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,524
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541784
Reka code 1101558
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 364
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,524
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029282
Reka code 1101558
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 364
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 1.2
Number of wires 1
Min. bending radius
During handling and installation, cable mm 80
In final installation, cable mm 30
During handling and installation, cable cm 8
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 1.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,524
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529287
Reka code 1101558

50 BK H07V2-R

Electric number Size Packaging Voltage

50 BK H07V2-R

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 494
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 94
In final installation, cable mm 35
During handling and installation, cable cm 9
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,387
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529331
Reka code 1101563
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 494
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 94
In final installation, cable mm 35
During handling and installation, cable cm 9
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,387
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004540831
Reka code 1101563
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 494
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 94
In final installation, cable mm 35
During handling and installation, cable cm 9
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,387
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029336
Reka code 1101563

50 BU H07V2-R

Electric number Size Packaging Voltage

50 BU H07V2-R

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 494
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 94
In final installation, cable mm 35
During handling and installation, cable cm 9
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,387
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029374
Reka code 1101567
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 494
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 94
In final installation, cable mm 35
During handling and installation, cable cm 9
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,387
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004540770
Reka code 1101567
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 494
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 94
In final installation, cable mm 35
During handling and installation, cable cm 9
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,387
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529379
Reka code 1101567

50 GNYE H07V2-R

Electric number Size Packaging Voltage

50 GNYE H07V2-R

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 494
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 94
In final installation, cable mm 35
During handling and installation, cable cm 9
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,387
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529386
Reka code 1101568
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 494
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 94
In final installation, cable mm 35
During handling and installation, cable cm 9
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,387
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029381
Reka code 1101568
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 494
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 94
In final installation, cable mm 35
During handling and installation, cable cm 9
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,387
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541883
Reka code 1101568

70 BK H07V2-R

Electric number Size Packaging Voltage

70 BK H07V2-R

Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 695
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 108
In final installation, cable mm 41
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,268
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541036
Reka code 1101573
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 695
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 108
In final installation, cable mm 41
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,268
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004540930
Reka code 1101573
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 695
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 108
In final installation, cable mm 41
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,268
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029435
Reka code 1101573
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 695
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 108
In final installation, cable mm 41
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,268
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529430
Reka code 1101573

70 BU H07V2-R

Electric number Size Packaging Voltage

70 BU H07V2-R

Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 695
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 108
In final installation, cable mm 41
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,268
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004540978
Reka code 1101577
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 695
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 108
In final installation, cable mm 41
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,268
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029473
Reka code 1101577
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 695
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 108
In final installation, cable mm 41
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,268
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529478
Reka code 1101577
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 695
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 108
In final installation, cable mm 41
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,268
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004540879
Reka code 1101577

70 GNYE H07V2-R

Electric number Size Packaging Voltage

70 GNYE H07V2-R

Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 694
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 108
In final installation, cable mm 40
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,268
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541289
Reka code 1101578
Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 694
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 108
In final installation, cable mm 40
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,268
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004529485
Reka code 1101578
Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 694
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 108
In final installation, cable mm 40
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,268
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029480
Reka code 1101578
Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 694
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.4
Number of wires 1
Min. bending radius
During handling and installation, cable mm 108
In final installation, cable mm 40
During handling and installation, cable cm 11
In final installation, cable cm 4
Max. pulling force
Pulling-eye kN 3.5
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,268
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541180
Reka code 1101578

95 BK H07V2-R

Electric number Size Packaging Voltage

95 BK H07V2-R

Nominal diameter of complete cable mm 16
Nominal weight of cable kg/km 970
Conductor material Copper
Nominal cross-sectional area of conductor mm2 95
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 126
In final installation, cable mm 47
During handling and installation, cable cm 13
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 4.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,193
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541135
Reka code 1101583
Nominal diameter of complete cable mm 16
Nominal weight of cable kg/km 970
Conductor material Copper
Nominal cross-sectional area of conductor mm2 95
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 126
In final installation, cable mm 47
During handling and installation, cable cm 13
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 4.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,193
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029534
Reka code 1101583

95 GNYE H07V2-R

Electric number Size Packaging Voltage

95 GNYE H07V2-R

Nominal diameter of complete cable mm 16
Nominal weight of cable kg/km 970
Conductor material Copper
Nominal cross-sectional area of conductor mm2 95
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 126
In final installation, cable mm 47
During handling and installation, cable cm 13
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 4.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,193
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541982
Reka code 1101588
Nominal diameter of complete cable mm 16
Nominal weight of cable kg/km 970
Conductor material Copper
Nominal cross-sectional area of conductor mm2 95
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 126
In final installation, cable mm 47
During handling and installation, cable cm 13
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 4.75
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,193
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029589
Reka code 1101588

120 BK H07V2-R

Electric number Size Packaging Voltage

120 BK H07V2-R

Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 1204
Conductor material Copper
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 139
In final installation, cable mm 52
During handling and installation, cable cm 14
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 6
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,153
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541333
Reka code 1101593
Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 1204
Conductor material Copper
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 139
In final installation, cable mm 52
During handling and installation, cable cm 14
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 6
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,153
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029633
Reka code 1101593
Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 1204
Conductor material Copper
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 139
In final installation, cable mm 52
During handling and installation, cable cm 14
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 6
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,153
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541234
Reka code 1101593

120 GNYE H07V2-R

Electric number Size Packaging Voltage

120 GNYE H07V2-R

Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 1204
Conductor material Copper
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 139
In final installation, cable mm 52
During handling and installation, cable cm 14
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 6
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,153
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541388
Reka code 1101598
Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 1204
Conductor material Copper
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 139
In final installation, cable mm 52
During handling and installation, cable cm 14
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 6
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,153
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004541487
Reka code 1101598
Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 1204
Conductor material Copper
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 1.6
Number of wires 1
Min. bending radius
During handling and installation, cable mm 139
In final installation, cable mm 52
During handling and installation, cable cm 14
In final installation, cable cm 5
Max. pulling force
Pulling-eye kN 6
Pulling-stocking kN 0
Resistance 20 °C Ω/km 0,153
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6410004029688
Reka code 1101598