FQLQ WF LiteRex
Download product group datasheet
Installation cable for fixed installations indoors and outdoors. Not to be laid in soil nor directly in cast concrete. Can be embedded to the groove filled with plaster. UV-protected oversheath and core insulation. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free and flame-retardant according to CPR-class Dca-s2,d2,a2.
Standards | SS 424 02 19-6 |
---|---|
Reaction to fire | Dca-s2,d2,a2 |
CPR - DoP | 2022001_DOP.pdf |
Conductor | Circular stranded copper, EN/IEC 60228 class 2 |
Insulation | Halogen free UV-resistant polyethylene |
Core Identification (all color combinations in the cable family) | Yellowgreen, blue, brown Yellowgreen, blue, brown, black Yellowgreen, blue, brown, black, grey |
Separation sheath | Halogen free filling compound |
Oversheath | Halogen free UV-resistant polyolefin compound |
Colour of the oversheath | White |
3G1,5
Electric number
Size
Packaging
Voltage
3G1,5
Nominal diameter of complete cable mm
11
Nominal weight of cable kg/km
148
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
3
Min. bending radius
During handling and installation, cable mm
99
In final installation, cable mm
30
During handling and installation, cable cm
10
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.23
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228722
Reka code
1254745
Nominal diameter of complete cable mm
11
Nominal weight of cable kg/km
148
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
3
Min. bending radius
During handling and installation, cable mm
99
In final installation, cable mm
30
During handling and installation, cable cm
10
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.23
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228739
Reka code
1254745
4G1,5
Electric number
Size
Packaging
Voltage
4G1,5
Nominal diameter of complete cable mm
11
Nominal weight of cable kg/km
170
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
4
Min. bending radius
During handling and installation, cable mm
102
In final installation, cable mm
31
During handling and installation, cable cm
10
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.3
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228753
Reka code
1254746
Nominal diameter of complete cable mm
11
Nominal weight of cable kg/km
170
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
4
Min. bending radius
During handling and installation, cable mm
102
In final installation, cable mm
31
During handling and installation, cable cm
10
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.3
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228746
Reka code
1254746
5G1,5
Electric number
Size
Packaging
Voltage
5G1,5
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
195
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
5
Min. bending radius
During handling and installation, cable mm
113
In final installation, cable mm
34
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228760
Reka code
1254747
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
195
Conductor material
Copper
Nominal diameter of conductor mm
1.36
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.5
Number of wires
5
Min. bending radius
During handling and installation, cable mm
113
In final installation, cable mm
34
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228777
Reka code
1254747
3G2,5
Electric number
Size
Packaging
Voltage
3G2,5
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
198
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
3
Min. bending radius
During handling and installation, cable mm
111
In final installation, cable mm
33
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228784
Reka code
1254749
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
198
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
3
Min. bending radius
During handling and installation, cable mm
111
In final installation, cable mm
33
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228791
Reka code
1254749
4G2,5
Electric number
Size
Packaging
Voltage
4G2,5
Nominal diameter of complete cable mm
13
Nominal weight of cable kg/km
232
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
4
Min. bending radius
During handling and installation, cable mm
117
In final installation, cable mm
35
During handling and installation, cable cm
12
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.5
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228807
Reka code
1254750
Nominal diameter of complete cable mm
13
Nominal weight of cable kg/km
232
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
4
Min. bending radius
During handling and installation, cable mm
117
In final installation, cable mm
35
During handling and installation, cable cm
12
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.5
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228814
Reka code
1254750
5G2,5
Electric number
Size
Packaging
Voltage
5G2,5
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
282
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
5
Min. bending radius
During handling and installation, cable mm
130
In final installation, cable mm
39
During handling and installation, cable cm
13
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.63
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228838
Reka code
1254751
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
282
Conductor material
Copper
Nominal diameter of conductor mm
1.74
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.6
Number of wires
5
Min. bending radius
During handling and installation, cable mm
130
In final installation, cable mm
39
During handling and installation, cable cm
13
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.63
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176228821
Reka code
1254751