AHXAMK-WP 36 kV

Cable is intended for fixed installations outdoors and may also be buried in soil. Cable is both longitudinally and radially watertight and therefore suitable where
wet soil and/or water permanently occurs. Suitable for ploughing. Not for submarine or similar applications

Conductor Watertight, circular, stranded aluminium EN/IEC 60228 class 2
Conductor screen Semiconducting cross-linked polyethylene XLPE
Insulation Cross-linked polyethylene XLPE
Insulation screen Semiconducting cross-linked polyethylene XLPE
Core Identification (all color combinations in the cable family) Black cores with white numbers
Cable lay up Three sheathed cores are laid up around a bare earth conductor
Metal screen PE-laminated aluminium foil bonded to the sheath
Oversheath Polyethylene
Colour of the oversheath Black

3x95

Electric number Size Packing (m) Voltage

3x95

Nominal diameter of complete cable (mm) 76
Nominal weight of cable (kg/km) 3332
Conductor material Aluminum
Nominal diameter of conductor (mm) 11
Nominal cross-sectional area of conductor (mm2) 0
Nominal thickness of insulation (mm) 8
Nominal diameter over the insulation without insulation screen (mm) 26.7
Nominal thickness of aluminium laminated foil (mm) 0.3
Nominal diameter of a sheathed phase conductor (mm) 35
Bending radius
During handling and installation, cable (cm) 912
In final installation, cable (cm) 638
During handling and installation, phase conductor (m) 0.53
During handling and installation, cable (m) 0.91
In final installation, phase conductor (m) 0.37
In final installation, cable (m) 0.64
Pulling force
Pulling-eye (kN) 14.3
Pulling-stocking (kN) 4.3
Resistance 20 °C (ohm/km) 0.32
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -20
Minimum cable temperature during operation (°C) -50
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 8.9
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 250
EAN code 6438176306116
Reka code 1181888

1x400

Electric number Size Packing (m) Voltage

1x400

Nominal diameter of complete cable (mm) 46
Nominal weight of cable (kg/km) 2193
Conductor material Aluminum
Nominal diameter of conductor (mm) 22
Nominal cross-sectional area of conductor (mm2) 0
Nominal thickness of insulation (mm) 8
Nominal diameter over the insulation without insulation screen (mm) 38
Nominal thickness of aluminium laminated foil (mm) 0.3
Bending radius
During handling and installation, cable (cm) 690
In final installation, cable (cm) 483
During handling and installation, cable (m) 0.68
In final installation, cable (m) 0.48
Pulling force
Pulling-eye (kN) 20
Pulling-stocking (kN) 6
Resistance 20 °C (ohm/km) 0.0778
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -20
Minimum cable temperature during operation (°C) -50
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 37.8
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 250
EAN code 6438176306062
Reka code 1181881

1x500

Electric number Size Packing (m) Voltage

1x500

Nominal diameter of complete cable (mm) 49
Nominal weight of cable (kg/km) 2671
Conductor material Aluminum
Nominal diameter of conductor (mm) 26
Nominal cross-sectional area of conductor (mm2) 0
Nominal thickness of insulation (mm) 8
Nominal diameter over the insulation without insulation screen (mm) 41.3
Nominal thickness of aluminium laminated foil (mm) 0.3
Bending radius
During handling and installation, cable (cm) 735
In final installation, cable (cm) 515
During handling and installation, cable (m) 0.74
In final installation, cable (m) 0.52
Pulling force
Pulling-eye (kN) 20
Pulling-stocking (kN) 7.5
Resistance 20 °C (ohm/km) 0.0605
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -20
Minimum cable temperature during operation (°C) -50
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 47.2
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 250
EAN code 6438176306079
Reka code 1181882

1x630

Electric number Size Packing (m) Voltage

1x630

Nominal diameter of complete cable (mm) 53
Nominal weight of cable (kg/km) 3266
Conductor material Aluminum
Nominal diameter of conductor (mm) 29
Nominal cross-sectional area of conductor (mm2) 0
Nominal thickness of insulation (mm) 8
Nominal diameter over the insulation without insulation screen (mm) 45.2
Nominal thickness of aluminium laminated foil (mm) 0.3
Bending radius
During handling and installation, cable (cm) 795
In final installation, cable (cm) 557
During handling and installation, cable (m) 0.8
In final installation, cable (m) 0.56
Pulling force
Pulling-eye (kN) 20
Pulling-stocking (kN) 8.5
Resistance 20 °C (ohm/km) 0.0469
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -20
Minimum cable temperature during operation (°C) -50
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 59.5
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 250
EAN code 6438176306086
Reka code 1181883

1x800

Electric number Size Packing (m) Voltage

1x800

Nominal diameter of complete cable (mm) 57
Nominal weight of cable (kg/km) 3946
Conductor material Aluminum
Nominal diameter of conductor (mm) 33
Nominal cross-sectional area of conductor (mm2) 0
Nominal thickness of insulation (mm) 8
Nominal diameter over the insulation without insulation screen (mm) 49.1
Nominal thickness of aluminium laminated foil (mm) 0.3
Bending radius
During handling and installation, cable (cm) 855
In final installation, cable (cm) 599
During handling and installation, cable (m) 0.86
In final installation, cable (m) 0.6
Pulling force
Pulling-eye (kN) 20
Pulling-stocking (kN) 8.5
Resistance 20 °C (ohm/km) 0.0367
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -20
Minimum cable temperature during operation (°C) -50
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 75.6
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 250
EAN code 6438176306093
Reka code 1181884

1x1000

Electric number Size Packing (m) Voltage

1x1000

Nominal diameter of complete cable (mm) 64
Nominal weight of cable (kg/km) 4722
Conductor material Aluminum
Nominal diameter of conductor (mm) 39
Nominal cross-sectional area of conductor (mm2) 0
Nominal thickness of insulation (mm) 8
Nominal diameter over the insulation without insulation screen (mm) 55
Nominal thickness of aluminium laminated foil (mm) 0.3
Bending radius
During handling and installation, cable (cm) 960
In final installation, cable (cm) 672
During handling and installation, cable (m) 0.95
In final installation, cable (m) 0.67
Pulling force
Pulling-eye (kN) 20
Pulling-stocking (kN) 8.5
Resistance 20 °C (ohm/km) 0.0291
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -20
Minimum cable temperature during operation (°C) -50
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 94.5
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 250
EAN code 6438176306109
Reka code 1181885

3x120

Electric number Size Packing (m) Voltage

3x120

Nominal diameter of complete cable (mm) 79
Nominal weight of cable (kg/km) 3732
Conductor material Aluminum
Nominal diameter of conductor (mm) 13
Nominal cross-sectional area of conductor (mm2) 0
Nominal thickness of insulation (mm) 8
Nominal diameter over the insulation without insulation screen (mm) 28.2
Nominal thickness of aluminium laminated foil (mm) 0.3
Nominal diameter of a sheathed phase conductor (mm) 37
Bending radius
During handling and installation, cable (cm) 948
In final installation, cable (cm) 664
During handling and installation, phase conductor (m) 0.55
During handling and installation, cable (m) 0.95
In final installation, phase conductor (m) 0.39
In final installation, cable (m) 0.66
Pulling force
Pulling-eye (kN) 18
Pulling-stocking (kN) 5.4
Resistance 20 °C (ohm/km) 0.253
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -20
Minimum cable temperature during operation (°C) -50
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 11.3
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 250
EAN code 6438176306123
Reka code 1181889

3x150

Electric number Size Packing (m) Voltage

3x150

Nominal diameter of complete cable (mm) 82
Nominal weight of cable (kg/km) 4108
Conductor material Aluminum
Nominal diameter of conductor (mm) 14
Nominal cross-sectional area of conductor (mm2) 0
Nominal thickness of insulation (mm) 8
Nominal diameter over the insulation without insulation screen (mm) 29.5
Nominal thickness of aluminium laminated foil (mm) 0.3
Nominal diameter of a sheathed phase conductor (mm) 38
Bending radius
During handling and installation, cable (cm) 984
In final installation, cable (cm) 689
During handling and installation, phase conductor (m) 0.57
During handling and installation, cable (m) 0.99
In final installation, phase conductor (m) 0.4
In final installation, cable (m) 0.69
Pulling force
Pulling-eye (kN) 20
Pulling-stocking (kN) 6.8
Resistance 20 °C (ohm/km) 0.206
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -20
Minimum cable temperature during operation (°C) -50
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 14.1
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 250
EAN code 6438176306260
Reka code 1181890

3x185

Electric number Size Packing (m) Voltage

3x185

Nominal diameter of complete cable (mm) 86
Nominal weight of cable (kg/km) 4625
Conductor material Aluminum
Nominal diameter of conductor (mm) 16
Nominal cross-sectional area of conductor (mm2) 0
Nominal thickness of insulation (mm) 8
Nominal diameter over the insulation without insulation screen (mm) 31.2
Nominal thickness of aluminium laminated foil (mm) 0.3
Nominal diameter of a sheathed phase conductor (mm) 40
Bending radius
During handling and installation, cable (cm) 1032
In final installation, cable (cm) 722
During handling and installation, phase conductor (m) 0.6
During handling and installation, cable (m) 1.03
In final installation, phase conductor (m) 0.42
In final installation, cable (m) 0.72
Pulling force
Pulling-eye (kN) 20
Pulling-stocking (kN) 8.3
Resistance 20 °C (ohm/km) 0.164
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -20
Minimum cable temperature during operation (°C) -50
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 17.4
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 250
EAN code 6438176306130
Reka code 1181891

3x240

Electric number Size Packing (m) Voltage

3x240

Nominal diameter of complete cable (mm) 92
Nominal weight of cable (kg/km) 5391
Conductor material Aluminum
Nominal diameter of conductor (mm) 18
Nominal cross-sectional area of conductor (mm2) 0
Nominal thickness of insulation (mm) 8
Nominal diameter over the insulation without insulation screen (mm) 33.6
Nominal thickness of aluminium laminated foil (mm) 0.3
Nominal diameter of a sheathed phase conductor (mm) 43
Bending radius
During handling and installation, cable (cm) 1104
In final installation, cable (cm) 773
During handling and installation, phase conductor (m) 0.64
During handling and installation, cable (m) 1.1
In final installation, phase conductor (m) 0.45
In final installation, cable (m) 0.77
Pulling force
Pulling-eye (kN) 20
Pulling-stocking (kN) 8.5
Resistance 20 °C (ohm/km) 0.125
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -20
Minimum cable temperature during operation (°C) -50
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 22.6
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 250
EAN code 6438176306147
Reka code 1181892

3x300

Electric number Size Packing (m) Voltage

3x300

Nominal diameter of complete cable (mm) 96
Nominal weight of cable (kg/km) 6166
Conductor material Aluminum
Nominal diameter of conductor (mm) 20
Nominal cross-sectional area of conductor (mm2) 0
Nominal thickness of insulation (mm) 8
Nominal diameter over the insulation without insulation screen (mm) 35.4
Nominal thickness of aluminium laminated foil (mm) 0.3
Nominal diameter of a sheathed phase conductor (mm) 45
Bending radius
During handling and installation, cable (cm) 1152
In final installation, cable (cm) 806
During handling and installation, phase conductor (m) 0.67
During handling and installation, cable (m) 1.15
In final installation, phase conductor (m) 0.47
In final installation, cable (m) 0.8
Pulling force
Pulling-eye (kN) 20
Pulling-stocking (kN) 8.5
Resistance 20 °C (ohm/km) 0.1
Minimum cable temperature during transport (°C) -40
Minimum cable temperature during handling and installation (°C) -20
Minimum cable temperature during operation (°C) -50
Maximum conductor temperature in normal operation (°C) 90
Phase (initial temperature 70 °C, final temperature 160 °C) 28.3
Maximum conductor temperature during short circuit (not exceeding 5 sec.) (°C) 250
EAN code 6438176306154