AHXAMK-W

For fixed installations outdoors and may also be buried in soil. Cable is both longitudinally and radially watertight and therefore suitable where wet soil and/or water permanently occurs. Suitable for ploughing. Not for submarine or similar applications.

Standards HD 620 S2:2010 Part 10 Section F, SFS 5636:2017
Conductor Watertight, circular, stranded aluminium, EN/IEC 60228 class 2
Conductor screen Semiconducting cross-linked polyethylene XLPE
Insulation Cross-linked polyethylene XLPE
Insulation screen Semiconducting cross-linked polyethylene XLPE
Core Identification (all color combinations in the cable family) Black insulation, white numbers
Inner covering Semiconducting waterswellable tape against longitudinal water penetration.
Metal screen Aluminium/plastic laminate, which acts also as a radial water barrier.
Oversheath PE-plastic
Colour of the oversheath Black

3x50+35 Cu

Electric number Size Packaging Voltage

3x50+35 Cu

Nominal diameter of complete cable mm 50
Nominal weight of cable kg/km 1778
Conductor material Aluminum
Nominal diameter of conductor mm 8
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 15.3
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 600
In final installation, cable mm 420
During handling and installation, phase conductor mm 0.36
In final installation, phase conductor mm 0.24
During handling and installation, cable cm 60
In final installation, cable cm 42
During handling and installation, cable m 0.6
In final installation, cable m 0.42
Max. pulling force
Pulling-eye kN 7.5
Pulling-stocking kN 2.3
Resistance 20 °C Ω/km 0.641
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176205655
Reka code 1187032
Nominal diameter of complete cable mm 50
Nominal weight of cable kg/km 1778
Conductor material Aluminum
Nominal diameter of conductor mm 8
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 15.3
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 600
In final installation, cable mm 420
During handling and installation, phase conductor mm 0.36
In final installation, phase conductor mm 0.24
During handling and installation, cable cm 60
In final installation, cable cm 42
During handling and installation, cable m 0.6
In final installation, cable m 0.42
Max. pulling force
Pulling-eye kN 7.5
Pulling-stocking kN 2.3
Resistance 20 °C Ω/km 0.641
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176300138
Reka code 1187032
Nominal diameter of complete cable mm 59
Nominal weight of cable kg/km 2243
Conductor material Aluminum
Nominal diameter of conductor mm 8
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 5.5
Nominal diameter over the insulation without insulation screen mm 19.3
Number of wires 3
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 708
In final installation, cable mm 496
During handling and installation, phase conductor mm 0.44
In final installation, phase conductor mm 0.3
During handling and installation, cable cm 71
In final installation, cable cm 50
During handling and installation, cable m 0.71
In final installation, cable m 0.5
Max. pulling force
Pulling-eye kN 7.5
Pulling-stocking kN 2.3
Resistance 20 °C Ω/km 0.641
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006224302
Reka code 1187002
Nominal diameter of complete cable mm 59
Nominal weight of cable kg/km 2243
Conductor material Aluminum
Nominal diameter of conductor mm 8
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 5.5
Nominal diameter over the insulation without insulation screen mm 19.3
Number of wires 3
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 708
In final installation, cable mm 496
During handling and installation, phase conductor mm 0.44
In final installation, phase conductor mm 0.3
During handling and installation, cable cm 71
In final installation, cable cm 50
During handling and installation, cable m 0.71
In final installation, cable m 0.5
Max. pulling force
Pulling-eye kN 7.5
Pulling-stocking kN 2.3
Resistance 20 °C Ω/km 0.641
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176205792
Reka code 1187002

3x70+35 Cu

Electric number Size Packaging Voltage

3x70+35 Cu

Nominal diameter of complete cable mm 53
Nominal weight of cable kg/km 2043
Conductor material Aluminum
Nominal diameter of conductor mm 9.6
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 16.7
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 636
In final installation, cable mm 445
During handling and installation, phase conductor mm 0.39
In final installation, phase conductor mm 0.26
During handling and installation, cable cm 64
In final installation, cable cm 45
During handling and installation, cable m 0.64
In final installation, cable m 0.45
Max. pulling force
Pulling-eye kN 10.5
Pulling-stocking kN 3.2
Resistance 20 °C Ω/km 0.443
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226023
Reka code 1187033
Nominal diameter of complete cable mm 53
Nominal weight of cable kg/km 2043
Conductor material Aluminum
Nominal diameter of conductor mm 9.6
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 16.7
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 636
In final installation, cable mm 445
During handling and installation, phase conductor mm 0.39
In final installation, phase conductor mm 0.26
During handling and installation, cable cm 64
In final installation, cable cm 45
During handling and installation, cable m 0.64
In final installation, cable m 0.45
Max. pulling force
Pulling-eye kN 10.5
Pulling-stocking kN 3.2
Resistance 20 °C Ω/km 0.443
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006225996
Reka code 1187033
Nominal diameter of complete cable mm 62
Nominal weight of cable kg/km 2531
Conductor material Aluminum
Nominal diameter of conductor mm 9.6
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 5.5
Nominal diameter over the insulation without insulation screen mm 20.7
Number of wires 3
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 744
In final installation, cable mm 521
During handling and installation, phase conductor mm 0.45
In final installation, phase conductor mm 0.32
During handling and installation, cable cm 74
In final installation, cable cm 52
During handling and installation, cable m 0.74
In final installation, cable m 0.52
Max. pulling force
Pulling-eye kN 10.5
Pulling-stocking kN 3.2
Resistance 20 °C Ω/km 0.443
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006224319
Reka code 1187003

3x95+35 Cu

Electric number Size Packaging Voltage

3x95+35 Cu

Nominal diameter of complete cable mm 57
Nominal weight of cable kg/km 2380
Conductor material Aluminum
Nominal diameter of conductor mm 11.1
Nominal cross-sectional area of conductor mm2 95
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 18.4
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 684
In final installation, cable mm 479
During handling and installation, phase conductor mm 0.42
In final installation, phase conductor mm 0.28
During handling and installation, cable cm 68
In final installation, cable cm 48
During handling and installation, cable m 0.68
In final installation, cable m 0.48
Max. pulling force
Pulling-eye kN 14.3
Pulling-stocking kN 4.3
Resistance 20 °C Ω/km 0,320
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226047
Reka code 1187034
Nominal diameter of complete cable mm 66
Nominal weight of cable kg/km 2905
Conductor material Aluminum
Nominal diameter of conductor mm 11.1
Nominal cross-sectional area of conductor mm2 95
Nominal thickness of insulation mm 5.5
Nominal diameter over the insulation without insulation screen mm 22.4
Number of wires 3
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 792
In final installation, cable mm 554
During handling and installation, phase conductor mm 0.48
In final installation, phase conductor mm 0.34
During handling and installation, cable cm 79
In final installation, cable cm 55
During handling and installation, cable m 0.79
In final installation, cable m 0.55
Max. pulling force
Pulling-eye kN 14.3
Pulling-stocking kN 4.3
Resistance 20 °C Ω/km 0,320
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006224326
Reka code 1187004

3x120+35 Cu

Electric number Size Packaging Voltage

3x120+35 Cu

Nominal diameter of complete cable mm 60
Nominal weight of cable kg/km 2702
Conductor material Aluminum
Nominal diameter of conductor mm 12.6
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 19.8
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 720
In final installation, cable mm 504
During handling and installation, phase conductor mm 0.44
In final installation, phase conductor mm 0.29
During handling and installation, cable cm 72
In final installation, cable cm 50
During handling and installation, cable m 0.72
In final installation, cable m 0.5
Max. pulling force
Pulling-eye kN 18
Pulling-stocking kN 5.4
Resistance 20 °C Ω/km 0.253
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226061
Reka code 1187035
Nominal diameter of complete cable mm 68
Nominal weight of cable kg/km 3200
Conductor material Aluminum
Nominal diameter of conductor mm 12.6
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 5.5
Nominal diameter over the insulation without insulation screen mm 23.4
Number of wires 3
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 816
In final installation, cable mm 571
During handling and installation, phase conductor mm 0.5
In final installation, phase conductor mm 0.35
During handling and installation, cable cm 82
In final installation, cable cm 57
During handling and installation, cable m 0.82
In final installation, cable m 0.57
Max. pulling force
Pulling-eye kN 18
Pulling-stocking kN 5.4
Resistance 20 °C Ω/km 0.253
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006224333
Reka code 1187005

3x150+35 Cu

Electric number Size Packaging Voltage

3x150+35 Cu

Nominal diameter of complete cable mm 63
Nominal weight of cable kg/km 3014
Conductor material Aluminum
Nominal diameter of conductor mm 13.9
Nominal cross-sectional area of conductor mm2 150
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 21.1
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 756
In final installation, cable mm 529
During handling and installation, phase conductor mm 0.47
In final installation, phase conductor mm 0.31
During handling and installation, cable cm 76
In final installation, cable cm 53
During handling and installation, cable m 0.76
In final installation, cable m 0.53
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 6.8
Resistance 20 °C Ω/km 0.206
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226085
Reka code 1187036
Nominal diameter of complete cable mm 71
Nominal weight of cable kg/km 3570
Conductor material Aluminum
Nominal diameter of conductor mm 13.9
Nominal cross-sectional area of conductor mm2 150
Nominal thickness of insulation mm 5.5
Nominal diameter over the insulation without insulation screen mm 25.1
Number of wires 3
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 852
In final installation, cable mm 596
During handling and installation, phase conductor mm 0.53
In final installation, phase conductor mm 0.37
During handling and installation, cable cm 85
In final installation, cable cm 60
During handling and installation, cable m 0.85
In final installation, cable m 0.6
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 6.8
Resistance 20 °C Ω/km 0.206
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006224340
Reka code 1187006

3x185+35 Cu

Electric number Size Packaging Voltage

3x185+35 Cu

Nominal diameter of complete cable mm 67
Nominal weight of cable kg/km 3475
Conductor material Aluminum
Nominal diameter of conductor mm 15.6
Nominal cross-sectional area of conductor mm2 185
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 23
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 804
In final installation, cable mm 563
During handling and installation, phase conductor mm 0.51
In final installation, phase conductor mm 0.34
During handling and installation, cable cm 80
In final installation, cable cm 56
During handling and installation, cable m 0.8
In final installation, cable m 0.56
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.3
Resistance 20 °C Ω/km 0.164
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226108
Reka code 1187037
Nominal diameter of complete cable mm 76
Nominal weight of cable kg/km 4091
Conductor material Aluminum
Nominal diameter of conductor mm 15.6
Nominal cross-sectional area of conductor mm2 185
Nominal thickness of insulation mm 5.5
Nominal diameter over the insulation without insulation screen mm 27
Number of wires 3
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 912
In final installation, cable mm 638
During handling and installation, phase conductor mm 0.56
In final installation, phase conductor mm 0.39
During handling and installation, cable cm 91
In final installation, cable cm 64
During handling and installation, cable m 0.91
In final installation, cable m 0.64
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.3
Resistance 20 °C Ω/km 0.164
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006224357
Reka code 1187007
Nominal diameter of complete cable mm 76
Nominal weight of cable kg/km 4091
Conductor material Aluminum
Nominal diameter of conductor mm 15.6
Nominal cross-sectional area of conductor mm2 185
Nominal thickness of insulation mm 5.5
Nominal diameter over the insulation without insulation screen mm 27
Number of wires 3
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 912
In final installation, cable mm 638
During handling and installation, phase conductor mm 0.56
In final installation, phase conductor mm 0.39
During handling and installation, cable cm 91
In final installation, cable cm 64
During handling and installation, cable m 0.91
In final installation, cable m 0.64
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.3
Resistance 20 °C Ω/km 0.164
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006224388
Reka code 1187007

3x240+35 Cu

Electric number Size Packaging Voltage

3x240+35 Cu

Nominal diameter of complete cable mm 72
Nominal weight of cable kg/km 4118
Conductor material Aluminum
Nominal diameter of conductor mm 18
Nominal cross-sectional area of conductor mm2 240
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 25.2
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 864
In final installation, cable mm 605
During handling and installation, phase conductor mm 0.53
In final installation, phase conductor mm 0.37
During handling and installation, cable cm 86
In final installation, cable cm 61
During handling and installation, cable m 0.86
In final installation, cable m 0.61
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0.125
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226122
Reka code 1187038
Nominal diameter of complete cable mm 82
Nominal weight of cable kg/km 4868
Conductor material Aluminum
Nominal diameter of conductor mm 18
Nominal cross-sectional area of conductor mm2 240
Nominal thickness of insulation mm 5.5
Nominal diameter over the insulation without insulation screen mm 29.2
Number of wires 3
Nominal thickness of aluminium laminated foil mm 0.3
Min. bending radius
During handling and installation, cable mm 984
In final installation, cable mm 689
During handling and installation, phase conductor mm 0.59
In final installation, phase conductor mm 0.41
During handling and installation, cable cm 98
In final installation, cable cm 69
During handling and installation, cable m 0.98
In final installation, cable m 0.69
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0.125
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006224500
Reka code 1187018

3x300+35 Cu

Electric number Size Packaging Voltage

3x300+35 Cu

Nominal diameter of complete cable mm 78
Nominal weight of cable kg/km 4863
Conductor material Aluminum
Nominal diameter of conductor mm 19.8
Nominal cross-sectional area of conductor mm2 300
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 27.5
Nominal thickness of aluminium laminated foil mm 0.2
Min. bending radius
During handling and installation, cable mm 936
In final installation, cable mm 655
During handling and installation, phase conductor mm 0.57
In final installation, phase conductor mm 0.38
During handling and installation, cable cm 94
In final installation, cable cm 66
During handling and installation, cable m 0.94
In final installation, cable m 0.66
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,100
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226559
Reka code 1187039
Nominal diameter of complete cable mm 86
Nominal weight of cable kg/km 5603
Conductor material Aluminum
Nominal diameter of conductor mm 19.8
Nominal cross-sectional area of conductor mm2 300
Nominal thickness of insulation mm 5.5
Nominal diameter over the insulation without insulation screen mm 31
Number of wires 3
Nominal thickness of aluminium laminated foil mm 0.3
Min. bending radius
During handling and installation, cable mm 1032
In final installation, cable mm 722
During handling and installation, phase conductor mm 0.62
In final installation, phase conductor mm 0.43
During handling and installation, cable cm 103
In final installation, cable cm 72
During handling and installation, cable m 1.03
In final installation, cable m 0.72
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,100
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176300084
Reka code 1187019

3x240+70 Cu

Electric number Size Packaging Voltage

3x240+70 Cu

Nominal diameter of complete cable mm 82
Nominal weight of cable kg/km 5173
Conductor material Aluminum
Nominal diameter of conductor mm 18
Nominal cross-sectional area of conductor mm2 240
Nominal thickness of insulation mm 5.5
Nominal diameter over the insulation without insulation screen mm 29.2
Number of wires 3
Nominal thickness of aluminium laminated foil mm 0.3
Min. bending radius
During handling and installation, cable mm 984
In final installation, cable mm 689
During handling and installation, phase conductor mm 0.59
In final installation, phase conductor mm 0.41
During handling and installation, cable cm 98
In final installation, cable cm 69
During handling and installation, cable m 0.98
In final installation, cable m 0.69
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0.125
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006224364
Reka code 1187008

3x300+70 Cu

Electric number Size Packaging Voltage

3x300+70 Cu

Nominal diameter of complete cable mm 86
Nominal weight of cable kg/km 5893
Conductor material Aluminum
Nominal diameter of conductor mm 19.8
Nominal cross-sectional area of conductor mm2 300
Nominal thickness of insulation mm 5.5
Nominal diameter over the insulation without insulation screen mm 31
Number of wires 3
Nominal thickness of aluminium laminated foil mm 0.3
Min. bending radius
During handling and installation, cable mm 1032
In final installation, cable mm 722
During handling and installation, phase conductor mm 0.62
In final installation, phase conductor mm 0.43
During handling and installation, cable cm 103
In final installation, cable cm 72
During handling and installation, cable m 1.03
In final installation, cable m 0.72
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,100
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006224371
Reka code 1187009