AHXAMK-W 6/10 (12) kV 3-core

Download product group datasheet

Medium-voltage cable for fixed installations outdoors. May be buried directly in soil, also by ploughing. Cable is longitudinally and radially watertight and therefore it is suitable where wet soil and / or fresh water permanently occurs. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free, but without fire protection. The cable is not CPR-classified.

Standards HD 620 10 F, SFS 5636
Conductor Watertight, circular, stranded aluminium, EN/IEC 60228 class 2
Conductor screen Semiconducting cross-linked polyethylene XLPE
Insulation Cross-linked polyethylene XLPE
Insulation screen Semiconducting cross-linked polyethylene XLPE
Core Identification (all color combinations in the cable family) White phase numbering: L1, L2, L3
Cable lay up Three sheathed cores are laid up around a bare earth conductor
Inner covering Semiconducting waterswellable tape against longitudinal water penetration
Metal screen Aluminium/plastic laminate, which acts also as a radial water barrier.
Oversheath PE-plastic PELLD
Colour of the oversheath Black

3x50+35 Cu

Electric number Size Packaging Voltage

3x50+35 Cu

Nominal diameter of complete cable mm 50
Nominal weight of cable kg/km 1778
Conductor material Aluminium
Nominal diameter of conductor mm 8
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 15.3
Number of wires 3
Min. bending radius
During handling and installation, phase conductor cm 35
During handling and installation, cable cm 60
In final installation, phase conductor cm 24
In final installation, cable cm 42
During handling and installation, phase conductor m 0.35
During handling and installation, cable m 0.6
In final installation, phase conductor m 0.24
In final installation, cable m 0.42
Max. pulling force
Pulling-eye kN 7.5
Pulling-stocking kN 2.3
Resistance 20 °C Ω/km 0,641
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176300138
Reka code 1187032

3x70+35 Cu

Electric number Size Packaging Voltage

3x70+35 Cu

Nominal diameter of complete cable mm 53
Nominal weight of cable kg/km 2043
Conductor material Aluminium
Nominal diameter of conductor mm 9.5
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 16.7
Number of wires 3
Min. bending radius
During handling and installation, phase conductor cm 38
During handling and installation, cable cm 64
In final installation, phase conductor cm 26
In final installation, cable cm 45
During handling and installation, phase conductor m 0.38
During handling and installation, cable m 0.64
In final installation, phase conductor m 0.26
In final installation, cable m 0.45
Max. pulling force
Pulling-eye kN 10.5
Pulling-stocking kN 3.2
Resistance 20 °C Ω/km 0,443
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226023
Reka code 1187033
Nominal diameter of complete cable mm 53
Nominal weight of cable kg/km 2043
Conductor material Aluminium
Nominal diameter of conductor mm 9.5
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 16.7
Number of wires 3
Min. bending radius
During handling and installation, phase conductor cm 38
During handling and installation, cable cm 64
In final installation, phase conductor cm 26
In final installation, cable cm 45
During handling and installation, phase conductor m 0.38
During handling and installation, cable m 0.64
In final installation, phase conductor m 0.26
In final installation, cable m 0.45
Max. pulling force
Pulling-eye kN 10.5
Pulling-stocking kN 3.2
Resistance 20 °C Ω/km 0,443
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006225996
Reka code 1187033

3x95+35 Cu

Electric number Size Packaging Voltage

3x95+35 Cu

Nominal diameter of complete cable mm 57
Nominal weight of cable kg/km 2380
Conductor material Aluminium
Nominal diameter of conductor mm 11.1
Nominal cross-sectional area of conductor mm2 95
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 18.4
Number of wires 3
Min. bending radius
During handling and installation, phase conductor cm 39
During handling and installation, cable cm 68
In final installation, phase conductor cm 27
In final installation, cable cm 48
During handling and installation, phase conductor m 0.39
During handling and installation, cable m 0.68
In final installation, phase conductor m 0.27
In final installation, cable m 0.48
Max. pulling force
Pulling-eye kN 14.3
Pulling-stocking kN 4.3
Resistance 20 °C Ω/km 0,320
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226047
Reka code 1187034

3x120+35 Cu

Electric number Size Packaging Voltage

3x120+35 Cu

Nominal diameter of complete cable mm 60
Nominal weight of cable kg/km 2702
Conductor material Aluminium
Nominal diameter of conductor mm 12.6
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 19.8
Number of wires 3
Min. bending radius
During handling and installation, phase conductor cm 42
During handling and installation, cable cm 72
In final installation, phase conductor cm 29
In final installation, cable cm 50
During handling and installation, phase conductor m 0.42
During handling and installation, cable m 0.72
In final installation, phase conductor m 0.29
In final installation, cable m 0.5
Max. pulling force
Pulling-eye kN 18
Pulling-stocking kN 5.4
Resistance 20 °C Ω/km 0,253
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226061
Reka code 1187035

3x150+35 Cu

Electric number Size Packaging Voltage

3x150+35 Cu

Nominal diameter of complete cable mm 63
Nominal weight of cable kg/km 3014
Conductor material Aluminium
Nominal diameter of conductor mm 13.9
Nominal cross-sectional area of conductor mm2 150
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 21.1
Number of wires 3
Min. bending radius
During handling and installation, phase conductor cm 44
During handling and installation, cable cm 76
In final installation, phase conductor cm 30
In final installation, cable cm 53
During handling and installation, phase conductor m 0.44
During handling and installation, cable m 0.76
In final installation, phase conductor m 0.3
In final installation, cable m 0.53
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 6.8
Resistance 20 °C Ω/km 0,206
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226085
Reka code 1187036

3x185+35 Cu

Electric number Size Packaging Voltage

3x185+35 Cu

Nominal diameter of complete cable mm 67
Nominal weight of cable kg/km 3475
Conductor material Aluminium
Nominal diameter of conductor mm 15.6
Nominal cross-sectional area of conductor mm2 185
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 23
Number of wires 3
Min. bending radius
During handling and installation, phase conductor cm 47
During handling and installation, cable cm 80
In final installation, phase conductor cm 33
In final installation, cable cm 56
During handling and installation, phase conductor m 0.47
During handling and installation, cable m 0.8
In final installation, phase conductor m 0.33
In final installation, cable m 0.56
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.3
Resistance 20 °C Ω/km 0,164
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226108
Reka code 1187037

3x240+35 Cu

Electric number Size Packaging Voltage

3x240+35 Cu

Nominal diameter of complete cable mm 72
Nominal weight of cable kg/km 4118
Conductor material Aluminium
Nominal diameter of conductor mm 18
Nominal cross-sectional area of conductor mm2 240
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 25.2
Number of wires 3
Min. bending radius
During handling and installation, phase conductor cm 51
During handling and installation, cable cm 86
In final installation, phase conductor cm 36
In final installation, cable cm 60
During handling and installation, phase conductor m 0.51
During handling and installation, cable m 0.86
In final installation, phase conductor m 0.36
In final installation, cable m 0.6
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,125
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226122
Reka code 1187038

3x300+35 Cu

Electric number Size Packaging Voltage

3x300+35 Cu

Nominal diameter of complete cable mm 78
Nominal weight of cable kg/km 4863
Conductor material Aluminium
Nominal diameter of conductor mm 19.8
Nominal cross-sectional area of conductor mm2 300
Nominal thickness of insulation mm 3.4
Nominal diameter over the insulation without insulation screen mm 27.5
Number of wires 3
Min. bending radius
During handling and installation, phase conductor cm 54
During handling and installation, cable cm 94
In final installation, phase conductor cm 38
In final installation, cable cm 66
During handling and installation, phase conductor m 0.54
During handling and installation, cable m 0.94
In final installation, phase conductor m 0.38
In final installation, cable m 0.66
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,100
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -20
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006226559
Reka code 1187039