2x1,5/1,5 | 1106105 | 50 coil |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 13 |
Weight kg/km | 190 |
Minimum allowed bending radius in installation (cm) | 14 |
Minimum allowed bending radius in final installation (cm) | 9 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,15 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 12,1 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106105 |
GTIN code | 6410006031023 |
|
2x1,5/1,5 | 1106105 | 100 coil |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 13 |
Weight kg/km | 190 |
Minimum allowed bending radius in installation (cm) | 14 |
Minimum allowed bending radius in final installation (cm) | 9 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,15 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 12,1 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106105 |
GTIN code | 6410006031122 |
|
2x1,5/1,5 | 1106105 | 200 Bobbin |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 13 |
Weight kg/km | 190 |
Minimum allowed bending radius in installation (cm) | 14 |
Minimum allowed bending radius in final installation (cm) | 9 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,15 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 12,1 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106105 |
GTIN code | 6410006031160 |
|
2x1,5/1,5 | 1106105 | 1000 K9 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 13 |
Weight kg/km | 190 |
Minimum allowed bending radius in installation (cm) | 14 |
Minimum allowed bending radius in final installation (cm) | 9 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,15 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 12,1 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106105 |
GTIN code | 6410006031221 |
|
2x2,5/2,5 | 1106106 | 50 coil |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 14 |
Weight kg/km | 230 |
Minimum allowed bending radius in installation (cm) | 15 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,25 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 7,41 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106106 |
GTIN code | 6410006031030 |
|
2x2,5/2,5 | 1106106 | 100 coil |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 14 |
Weight kg/km | 230 |
Minimum allowed bending radius in installation (cm) | 15 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,25 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 7,41 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106106 |
GTIN code | 6410006031139 |
|
2x2,5/2,5 | 1106106 | 150 Bobbin |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 14 |
Weight kg/km | 230 |
Minimum allowed bending radius in installation (cm) | 15 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,25 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 7,41 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106106 |
GTIN code | 6410006031177 |
|
2x2,5/2,5 | 1106106 | 1000 K9 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 14 |
Weight kg/km | 230 |
Minimum allowed bending radius in installation (cm) | 15 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,25 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 7,41 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106106 |
GTIN code | 6410006031238 |
|
2x6/6 | 1106108 | 500 K10 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 18 |
Weight kg/km | 400 |
Minimum allowed bending radius in installation (cm) | 19 |
Minimum allowed bending radius in final installation (cm) | 12 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,60 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 3,08 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106108 |
GTIN code | 6410006031061 |
|
2x6/6 | 1106108 | 1000 K11 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 18 |
Weight kg/km | 400 |
Minimum allowed bending radius in installation (cm) | 19 |
Minimum allowed bending radius in final installation (cm) | 12 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,60 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 3,08 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106108 |
GTIN code | 6410006031252 |
|
2x10/10 | 1106149 | 500 K11 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 21 |
Weight kg/km | 580 |
Minimum allowed bending radius in installation (cm) | 22 |
Minimum allowed bending radius in final installation (cm) | 15 |
Maximum allowed pulling force when pulling from conductors (kN) | 1,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 1,83 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106149 |
GTIN code | 6410006031108 |
|
2x10/10 | 1106149 | 1000 K12 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 21 |
Weight kg/km | 580 |
Minimum allowed bending radius in installation (cm) | 22 |
Minimum allowed bending radius in final installation (cm) | 15 |
Maximum allowed pulling force when pulling from conductors (kN) | 1,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 1,83 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106149 |
GTIN code | 6410006031269 |
|
3x1,5/1,5 | 1106305 | 100 coil |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 13 |
Weight kg/km | 170 |
Minimum allowed bending radius in installation (cm) | 13 |
Minimum allowed bending radius in final installation (cm) | 9 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,23 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 12,1 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106305 |
GTIN code | 6410006031825 |
|
3x1,5/1,5 | 1106305 | 1000 K9 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 13 |
Weight kg/km | 170 |
Minimum allowed bending radius in installation (cm) | 13 |
Minimum allowed bending radius in final installation (cm) | 9 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,23 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 12,1 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106305 |
GTIN code | 6410006031528 |
|
3x2,5/2,5 | 1106306 | 100 coil |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 13 |
Weight kg/km | 210 |
Minimum allowed bending radius in installation (cm) | 14 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,38 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 7,41 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106306 |
GTIN code | 6410006031832 |
|
3x2,5/2,5 | 1106306 | 1000 K9 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 13 |
Weight kg/km | 210 |
Minimum allowed bending radius in installation (cm) | 14 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,38 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 7,41 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106306 |
GTIN code | 6410006031535 |
|
3x6/6 | 1106308 | 500 K9 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 17 |
Weight kg/km | 390 |
Minimum allowed bending radius in installation (cm) | 18 |
Minimum allowed bending radius in final installation (cm) | 12 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,90 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 3,08 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106308 |
GTIN code | 6410006031276 |
|
3x6/6 | 1106308 | 1000 K11 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 17 |
Weight kg/km | 390 |
Minimum allowed bending radius in installation (cm) | 18 |
Minimum allowed bending radius in final installation (cm) | 12 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,90 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 3,08 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106308 |
GTIN code | 6410006031559 |
|
3x10/10 | 1106302 | 500 K11 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 21 |
Weight kg/km | 590 |
Minimum allowed bending radius in installation (cm) | 22 |
Minimum allowed bending radius in final installation (cm) | 15 |
Maximum allowed pulling force when pulling from conductors (kN) | 1,50 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 1,83 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106302 |
GTIN code | 6410006031283 |
|
3x10/10 | 1106302 | 1000 K12 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 21 |
Weight kg/km | 590 |
Minimum allowed bending radius in installation (cm) | 22 |
Minimum allowed bending radius in final installation (cm) | 15 |
Maximum allowed pulling force when pulling from conductors (kN) | 1,50 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 1,83 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106302 |
GTIN code | 6410006031566 |
|
3x16/16 | 1106310 | 500 K11 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 23 |
Weight kg/km | 850 |
Minimum allowed bending radius in installation (cm) | 25 |
Minimum allowed bending radius in final installation (cm) | 17 |
Maximum allowed pulling force when pulling from conductors (kN) | 2,40 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 1,15 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106310 |
GTIN code | 6410006031290 |
|
3x16/16 | 1106310 | 1000 K14 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 23 |
Weight kg/km | 850 |
Minimum allowed bending radius in installation (cm) | 25 |
Minimum allowed bending radius in final installation (cm) | 17 |
Maximum allowed pulling force when pulling from conductors (kN) | 2,40 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 1,15 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106310 |
GTIN code | 6410006031573 |
|
3x25/16 | 1106304 | 500 K12 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 28 |
Weight kg/km | 1170 |
Minimum allowed bending radius in installation (cm) | 30 |
Minimum allowed bending radius in final installation (cm) | 20 |
Maximum allowed pulling force when pulling from conductors (kN) | 3,75 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,727 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106304 |
GTIN code | 6410006031672 |
|
3x25/16 | 1106304 | 1000 K16 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 28 |
Weight kg/km | 1170 |
Minimum allowed bending radius in installation (cm) | 30 |
Minimum allowed bending radius in final installation (cm) | 20 |
Maximum allowed pulling force when pulling from conductors (kN) | 3,75 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,727 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106304 |
GTIN code | 6410006031580 |
|
4x1,5/1,5 | 1106435 | 100 coil |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 13 |
Weight kg/km | 190 |
Minimum allowed bending radius in installation (cm) | 14 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,30 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 12,1 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106435 |
GTIN code | 6410006031924 |
|
4x1,5/1,5 | 1106435 | 50 coil |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 13 |
Weight kg/km | 190 |
Minimum allowed bending radius in installation (cm) | 14 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,30 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 12,1 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106435 |
GTIN code | 6410006031849 |
|
4x1,5/1,5 | 1106435 | 150 Bobbin |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 13 |
Weight kg/km | 190 |
Minimum allowed bending radius in installation (cm) | 14 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,30 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 12,1 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106435 |
GTIN code | 6410006031863 |
|
4x1,5/1,5 | 1106435 | 1000 K9 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 13 |
Weight kg/km | 190 |
Minimum allowed bending radius in installation (cm) | 14 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,30 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 12,1 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106435 |
GTIN code | 6410006031726 |
|
4x2,5/2,5 | 1106436 | 50 coil |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 14 |
Weight kg/km | 250 |
Minimum allowed bending radius in installation (cm) | 15 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,50 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 7,41 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106436 |
GTIN code | 6410006031856 |
|
4x2,5/2,5 | 1106436 | 100 coil |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 14 |
Weight kg/km | 250 |
Minimum allowed bending radius in installation (cm) | 15 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,50 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 7,41 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106436 |
GTIN code | 6410006031931 |
|
4x2,5/2,5 | 1106436 | 150 Bobbin |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 14 |
Weight kg/km | 250 |
Minimum allowed bending radius in installation (cm) | 15 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,50 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 7,41 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106436 |
GTIN code | 6410006031870 |
|
4x2,5/2,5 | 1106436 | 1000 K9 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 14 |
Weight kg/km | 250 |
Minimum allowed bending radius in installation (cm) | 15 |
Minimum allowed bending radius in final installation (cm) | 10 |
Maximum allowed pulling force when pulling from conductors (kN) | 0,50 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 7,41 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106436 |
GTIN code | 6410006031733 |
|
4x6/6 | 1106438 | 500 K10 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 19 |
Weight kg/km | 480 |
Minimum allowed bending radius in installation (cm) | 20 |
Minimum allowed bending radius in final installation (cm) | 13 |
Maximum allowed pulling force when pulling from conductors (kN) | 1,20 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 3,08 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106438 |
GTIN code | 6410006031306 |
|
4x6/6 | 1106438 | 1000 K12 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 19 |
Weight kg/km | 480 |
Minimum allowed bending radius in installation (cm) | 20 |
Minimum allowed bending radius in final installation (cm) | 13 |
Maximum allowed pulling force when pulling from conductors (kN) | 1,20 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 3,08 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106438 |
GTIN code | 6410006031757 |
|
4x10/10 | 1106449 | 500 K11 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 22 |
Weight kg/km | 720 |
Minimum allowed bending radius in installation (cm) | 24 |
Minimum allowed bending radius in final installation (cm) | 16 |
Maximum allowed pulling force when pulling from conductors (kN) | 2,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 1,83 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106449 |
GTIN code | 6410006031313 |
|
4x10/10 | 1106449 | 1000 K14 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 22 |
Weight kg/km | 720 |
Minimum allowed bending radius in installation (cm) | 24 |
Minimum allowed bending radius in final installation (cm) | 16 |
Maximum allowed pulling force when pulling from conductors (kN) | 2,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 1,83 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106449 |
GTIN code | 6410006031764 |
|
4x16/16 | 1106410 | 500 K12 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 25 |
Weight kg/km | 1050 |
Minimum allowed bending radius in installation (cm) | 27 |
Minimum allowed bending radius in final installation (cm) | 18 |
Maximum allowed pulling force when pulling from conductors (kN) | 3,20 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 1,15 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106410 |
GTIN code | 6410006031344 |
|
4x16/16 | 1106410 | 1000 K16 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 25 |
Weight kg/km | 1050 |
Minimum allowed bending radius in installation (cm) | 27 |
Minimum allowed bending radius in final installation (cm) | 18 |
Maximum allowed pulling force when pulling from conductors (kN) | 3,20 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 1,15 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106410 |
GTIN code | 6410006031771 |
|
4x25/16 | 1106411 | 1000 K18 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 30 |
Weight kg/km | 1460 |
Minimum allowed bending radius in installation (cm) | 33 |
Minimum allowed bending radius in final installation (cm) | 22 |
Maximum allowed pulling force when pulling from conductors (kN) | 5,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,727 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106411 |
GTIN code | 6410006023882 |
|
3x35/16 | 1106312 | 500 K12 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 27 |
Weight kg/km | 1420 |
Minimum allowed bending radius in installation (cm) | 29 |
Minimum allowed bending radius in final installation (cm) | 19 |
Maximum allowed pulling force when pulling from conductors (kN) | 5,25 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,524 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106312 |
GTIN code | 6410006031689 |
|
3x35/16 | 1106312 | 1000 K16 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 27 |
Weight kg/km | 1420 |
Minimum allowed bending radius in installation (cm) | 29 |
Minimum allowed bending radius in final installation (cm) | 19 |
Maximum allowed pulling force when pulling from conductors (kN) | 5,25 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,524 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106312 |
GTIN code | 6410006031597 |
|
3x50/25 | 1106313 | 500 K14 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 30 |
Weight kg/km | 1950 |
Minimum allowed bending radius in installation (cm) | 33 |
Minimum allowed bending radius in final installation (cm) | 22 |
Maximum allowed pulling force when pulling from conductors (kN) | 7,50 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,387 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106313 |
GTIN code | 6410006031696 |
|
3x50/25 | 1106313 | 1000 K18 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 30 |
Weight kg/km | 1950 |
Minimum allowed bending radius in installation (cm) | 33 |
Minimum allowed bending radius in final installation (cm) | 22 |
Maximum allowed pulling force when pulling from conductors (kN) | 7,50 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,387 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106313 |
GTIN code | 6410006031603 |
|
3x70/35 | 1106314 | 500 K14 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 33 |
Weight kg/km | 2640 |
Minimum allowed bending radius in installation (cm) | 37 |
Minimum allowed bending radius in final installation (cm) | 25 |
Maximum allowed pulling force when pulling from conductors (kN) | 10,50 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,268 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106314 |
GTIN code | 6410006031702 |
|
3x70/35 | 1106314 | 1000 K20 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 33 |
Weight kg/km | 2640 |
Minimum allowed bending radius in installation (cm) | 37 |
Minimum allowed bending radius in final installation (cm) | 25 |
Maximum allowed pulling force when pulling from conductors (kN) | 10,50 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,268 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106314 |
GTIN code | 6410006031610 |
|
3x95/50 | 1106315 | 500 K16 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 37 |
Weight kg/km | 3620 |
Minimum allowed bending radius in installation (cm) | 42 |
Minimum allowed bending radius in final installation (cm) | 28 |
Maximum allowed pulling force when pulling from conductors (kN) | 14,25 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,193 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106315 |
GTIN code | 6410006031719 |
|
3x95/50 | 1106315 | 1000 K22 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 37 |
Weight kg/km | 3620 |
Minimum allowed bending radius in installation (cm) | 42 |
Minimum allowed bending radius in final installation (cm) | 28 |
Maximum allowed pulling force when pulling from conductors (kN) | 14,25 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,193 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106315 |
GTIN code | 6410006031627 |
|
3x120/70 | 1106316 | 500 K18 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 41 |
Weight kg/km | 4530 |
Minimum allowed bending radius in installation (cm) | 46 |
Minimum allowed bending radius in final installation (cm) | 31 |
Maximum allowed pulling force when pulling from conductors (kN) | 18,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,153 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106316 |
GTIN code | 6410006031634 |
|
3x150/70 | 1106317 | 500 K20 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 44 |
Weight kg/km | 5430 |
Minimum allowed bending radius in installation (cm) | 50 |
Minimum allowed bending radius in final installation (cm) | 34 |
Maximum allowed pulling force when pulling from conductors (kN) | 20,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,124 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106317 |
GTIN code | 6410006031641 |
|
3x185/95 | 1106318 | 500 K22 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 50 |
Weight kg/km | 6880 |
Minimum allowed bending radius in installation (cm) | 57 |
Minimum allowed bending radius in final installation (cm) | 38 |
Maximum allowed pulling force when pulling from conductors (kN) | 20,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,0991 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106318 |
GTIN code | 6410006031658 |
|
3x240/120 | 1106319 | 500 K24 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 56 |
Weight kg/km | 8940 |
Minimum allowed bending radius in installation (cm) | 64 |
Minimum allowed bending radius in final installation (cm) | 43 |
Maximum allowed pulling force when pulling from conductors (kN) | 20,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,0754 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106319 |
GTIN code | 6410006031665 |
|
4x35/16 | 1106412 | 500 K14 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 29 |
Weight kg/km | 1800 |
Minimum allowed bending radius in installation (cm) | 32 |
Minimum allowed bending radius in final installation (cm) | 21 |
Maximum allowed pulling force when pulling from conductors (kN) | 7,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,524 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106412 |
GTIN code | 6410006023769 |
|
4x35/16 | 1106412 | 1000 K18 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 29 |
Weight kg/km | 1800 |
Minimum allowed bending radius in installation (cm) | 32 |
Minimum allowed bending radius in final installation (cm) | 21 |
Maximum allowed pulling force when pulling from conductors (kN) | 7,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,524 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106412 |
GTIN code | 6410006023790 |
|
4x50/25 | 1106413 | 500 K14 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 33 |
Weight kg/km | 2500 |
Minimum allowed bending radius in installation (cm) | 37 |
Minimum allowed bending radius in final installation (cm) | 24 |
Maximum allowed pulling force when pulling from conductors (kN) | 10,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,387 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106413 |
GTIN code | 6410006023776 |
|
4x50/25 | 1106413 | 1000 K20 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 33 |
Weight kg/km | 2500 |
Minimum allowed bending radius in installation (cm) | 37 |
Minimum allowed bending radius in final installation (cm) | 24 |
Maximum allowed pulling force when pulling from conductors (kN) | 10,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,387 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106413 |
GTIN code | 6410006023806 |
|
4x70/35 | 1106414 | 500 K16 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 36 |
Weight kg/km | 3360 |
Minimum allowed bending radius in installation (cm) | 40 |
Minimum allowed bending radius in final installation (cm) | 27 |
Maximum allowed pulling force when pulling from conductors (kN) | 14,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,268 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106414 |
GTIN code | 6410006023783 |
|
4x70/35 | 1106414 | 1000 K22 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 36 |
Weight kg/km | 3360 |
Minimum allowed bending radius in installation (cm) | 40 |
Minimum allowed bending radius in final installation (cm) | 27 |
Maximum allowed pulling force when pulling from conductors (kN) | 14,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,268 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106414 |
GTIN code | 6410006023813 |
|
4x95/50 | 1106415 | 500 K18 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 41 |
Weight kg/km | 4600 |
Minimum allowed bending radius in installation (cm) | 46 |
Minimum allowed bending radius in final installation (cm) | 31 |
Maximum allowed pulling force when pulling from conductors (kN) | 19,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,193 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106415 |
GTIN code | 6410006023820 |
|
4x120/70 | 1106416 | 500 K20 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 44 |
Weight kg/km | 5730 |
Minimum allowed bending radius in installation (cm) | 50 |
Minimum allowed bending radius in final installation (cm) | 34 |
Maximum allowed pulling force when pulling from conductors (kN) | 20,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,153 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106416 |
GTIN code | 6410006023837 |
|
4x150/70 | 1106417 | 500 K22 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 48 |
Weight kg/km | 6930 |
Minimum allowed bending radius in installation (cm) | 55 |
Minimum allowed bending radius in final installation (cm) | 36 |
Maximum allowed pulling force when pulling from conductors (kN) | 20,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,124 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106417 |
GTIN code | 6410006023844 |
|
4x185/95 | 1106418 | 500 K24 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 56 |
Weight kg/km | 8800 |
Minimum allowed bending radius in installation (cm) | 64 |
Minimum allowed bending radius in final installation (cm) | 43 |
Maximum allowed pulling force when pulling from conductors (kN) | 20,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,0991 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106418 |
GTIN code | 6410006023851 |
|
4x240/120 | 1106419 | 400 K26 |
Voltage | 0,6/1 (1,2) kV |
Diameter (mm) | 62 |
Weight kg/km | 11460 |
Minimum allowed bending radius in installation (cm) | 71 |
Minimum allowed bending radius in final installation (cm) | 48 |
Maximum allowed pulling force when pulling from conductors (kN) | 20,00 |
Maximum DC resistance of phase conductor, +20°C (ohm/km) | 0,0754 |
Minimum handling temperature (°C) | -15 |
Maximum conductor temperature (°C) | 70 |
Conductor short-circuit temperature, 5 s (°C) | 160 |
Product number | 1106419 |
GTIN code | 6410006023868 |
|