For fixed installation indoors and outdoors, not to be laid directly in soil nor in cast concrete. For data transmission in automation, instrumentation and process control systems.
EN 50288-7 Applicable parts
Special property:
Flame retardant EN 60332-3-23, halogen free EN 60754-2, low smoke EN 61034-2, EMC-protected, pair screened
CPR - DoP:
Conductor:
Stranded, circular, tinned copper
Insulation:
Halogen free polyolefin
Identification:
Colours in the pair blue and red
Al screen:
Two layers of polyester aluminium tape. Aluminium sides against each other, an earth conductor of circular, stranded, tinned copper 0,5 mm² between the tape layers.
Twisted pair:
Cores twisted to pairs
Pair screening:
Polyester-aluminium tape, sequential pair numbering on tape Cores twisted to pairs with an earth conductor of stranded, circular, tinned copper 0,5 mm².
Bedding:
Halogen free Filling sheath
Outer sheath:
Grey, halogen free UV-resistant polyolefin